Monte Carlo calculation of dosimetry parameters for a brachytherapy source

被引:2
作者
Belousov, A. V. [1 ]
Kalachev, A. A. [1 ]
Osipov, A. S. [1 ]
机构
[1] Moscow MV Lomonosov State Univ, Dept Phys, Moscow 119991, Russia
关键词
brachytherapy source; Monte Carlo; GEANT4; TG-43; TECHNICAL NOTE; IR-192;
D O I
10.3103/S0027134914060034
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This study presents the results of calculations of dosimetry parameters for a Yb-169 model brachytherapy source. The calculations were performed by a program code that was written by the authors using the GEANT4.9 software package for Monte Carlo simulation. According to the AAPM TG-43 formalism (the American Association of Physicists in Medicine, Task Group No. 43), the following parameters were deter- mined: the dose-rate constant, radial dose functions, and anisotropy function. To verify the program code, the calculation of the dosimetry parameters of the widespread BEBIG Co0.A86 and BEBIG Ir2.A85-2 sources was carried out. An acceptable fit with the data of other authors was obtained. The data we obtained using the developed and verified program code could be used in dosimetry planning systems.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 20 条
[1]  
Akulinichev S. V., P 6 TROITSK C MED PH, P211
[2]   Monte Carlo dosimetric study of the BEBIG Co-60HDR source [J].
Ballester, F ;
Granero, D ;
Pérez-Calatayud, J ;
Casal, E ;
Agramunt, S ;
Cases, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) :N309-N316
[3]   Monte Carlo dosimetric study of best industries and alpha omega Ir-192 brachytherapy seeds [J].
Ballester, F ;
Granero, D ;
Pérez-Calatayud, J ;
Casal, E ;
Puchades, V .
MEDICAL PHYSICS, 2004, 31 (12) :3298-3305
[4]   Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source [J].
Daskalov, GM ;
Loffler, E ;
Williamson, JF .
MEDICAL PHYSICS, 1998, 25 (11) :2200-2208
[5]   Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources [J].
Granero, D. ;
Perez-Calatayud, J. ;
Ballester, F. .
MEDICAL PHYSICS, 2008, 35 (04) :1280-1287
[6]   Technical note:: Dosimetric study of a. new Co-60 source used in brachytherapy [J].
Granero, D. ;
Perez-Calatayud, J. ;
Ballester, F. .
MEDICAL PHYSICS, 2007, 34 (09) :3485-3488
[7]   Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192HDR source [J].
Granero, D ;
Pérez-Calatayud, J ;
Ballester, F .
RADIOTHERAPY AND ONCOLOGY, 2005, 76 (01) :79-85
[8]   Equivalent phantom sizes and shapes for brachytherapy dosimetric studies of 192Ir and 137Cs [J].
Granero, Domingo ;
Perez-Calatayud, Jose ;
Pujades-Claumarchirant, MCarmen ;
Ballester, Facundo ;
Melhus, Christopher S. ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2008, 35 (11) :4872-4877
[9]   Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE [J].
Javier Casado, Francisco ;
Garcia-Pareja, Salvador ;
Cenizo, Elena ;
Mateo, Beatriz ;
Bodineau, Coral ;
Galan, Pedro .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2010, 26 (03) :132-139
[10]   Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 kev [J].
Li, Zuofeng ;
Das, Rupak K. ;
DeWerd, Larry A. ;
Ibbott, Geoffrey S. ;
Meigooni, Ali S. ;
Perez-Calatayud, Jose ;
Rivard, Mark J. ;
Sloboda, Ronald S. ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2007, 34 (01) :37-40