Step-by-Step Controller Design of Voltage Closed-Loop Control for Virtual Synchronous Generator

被引:0
作者
Chen, Xinran [1 ]
Ruan, Xinbo [1 ]
Yang, Dongsheng [1 ]
Wu, Heng [1 ]
Zhao, Wenxin [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Aeropower Sci Tech Ctr, Nanjing, Jiangsu, Peoples R China
来源
2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2015年
关键词
INVERTER;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Virtual synchronous generator (VSG) is a control scheme applied to the inverter of a distributed generating unit in order to support power system stability by imitating the behavior of a synchronous generator. A lot of effort has been dedicated to investigating the power stage control of VSG, but the waveform quality of VSG is not fully discussed. This paper analyses a VSG with an inner voltage loop to attenuate waveform distortion influenced by dead-time effect. And main parts of the voltage loop are voltage regulator and active damping of the LCL filter. Generally speaking, the voltage regulator attenuates the influence of dead-time effect, and the active damping suppresses the resonance peak caused by the LCL filter and makes it easier to stabilize the whole system. Based on the proportional-resonant (PR) compensator together with capacitor-current-feedback active damping which is widely used for their effectiveness and simple implementations, a step-by-step design method of the controller parameters for voltage loop is proposed. By carefully dealing with the interaction between the voltage regulator and active damping, the satisfactory regions of the controller parameters for meeting the system specifications are obtained, from which the controller parameters can be easily picked out. Simulation results verify the effectiveness of inner voltage loop.
引用
收藏
页码:3760 / 3765
页数:6
相关论文
共 11 条
[1]  
Chen Yan Chen Yan, 2011, Guizhou Agricultural Sciences, P1
[2]   Inverter output voltage synthesis using novel dead time compensation [J].
Choi, JW ;
Sul, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (02) :221-227
[3]   Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633
[4]  
Erickson R.W., 2001, FUNDAMENTALS POWER E, P331
[5]   A PI-type dead-time compensation method for vector-controlled GTO inverters [J].
Jung, J ;
Nam, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (03) :452-457
[6]  
Loix T, 2011, Deelname van omvormergekoppelde gedistribueerde energiebronnen aan de regeling van de netspanning
[7]   On-line dead-time compensation technique for open-loop PWM-VSI drives [J].
Muñoz, AR ;
Lipo, TA .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (04) :683-689
[8]   Analytical technique for calculating the output harmonics of an H-bridge inverter with dead time [J].
Wu, CM ;
Lau, WH ;
Chung, HSH .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 1999, 46 (05) :617-627
[9]   A Bandpass Filter Incorporated Into the Inductor Current Feedback Path for Improving Dynamic Performance of the Front-End DC-DC Converter in Two-Stage Inverter [J].
Zhang, Li ;
Ren, Xiaoyong ;
Ruan, Xinbo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (05) :2316-2325
[10]   Synchronverters: Inverters That Mimic Synchronous Generators [J].
Zhong, Qing-Chang ;
Weiss, George .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (04) :1259-1267