Detection of radiation-exposure biomarkers by differential mobility prefiltered mass spectrometry (DMS-MS)

被引:44
作者
Coy, Stephen L. [1 ]
Krylov, Evgeny V. [1 ]
Schneider, Bradley B. [2 ]
Covey, Thomas R. [2 ]
Brenner, David J. [3 ]
Tyburski, John B. [4 ]
Patterson, Andrew D. [4 ]
Krausz, Kris W. [4 ]
Fornace, Albert J. [5 ,6 ]
Nazarova, Erkinjon G. [1 ]
机构
[1] Sionex Corp, Bedford, MA 01730 USA
[2] AB SCIEX, Concord, ON L4K 4V8, Canada
[3] Columbia Univ, Ctr Radiol Res, New York, NY 10032 USA
[4] NCI, Ctr Canc Res, Lab Metab, Bethesda, MD 20892 USA
[5] Georgetown Univ, Lombardi Comprehens Canc Ctr, Washington, DC 20057 USA
[6] Georgetown Univ, Dept Biochem & Mol & Cellular Biol, Washington, DC 20057 USA
关键词
Metabolomic; Radiation exposure; DMS; Ion mobility; Electrospray; ELECTROSPRAY-IONIZATION; N-HEXANOYLGLYCINE; URINE; METABOLOMICS; SEPARATION; SYSTEM; GAS; IDENTIFICATION; MICE;
D O I
10.1016/j.ijms.2010.01.013
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Technology to enable rapid screening for radiation exposure has been identified as an important need, and, as a part of a NIH/NIAD effort in this direction, metabolomic biomarkers for radiation exposure have been identified in a recent series of papers. To reduce the time necessary to detect and measure these biomarkers, differential mobility spectrometry-mass spectrometry (DMS-MS) systems have been developed and tested. Differential mobility ion filters preselect specific ions and also suppress chemical noise created in typical atmospheric-pressure ionization sources (ESI, MALDI, and others). Differential-mobility-based ion selection is based on the field dependence of ion mobility, which, in turn, depends on ion characteristics that include conformation, charge distribution, molecular polarizability, and other properties, and on the transport gas composition which can be modified to enhance resolution. DMS-MS is able to resolve small-molecule biomarkers from isobaric interferences, and suppresses chemical noise generated in the ion source and in the mass spectrometer, improving selectivity and quantitative accuracy. Our planar DMS design is rapid, operating in a few milliseconds, and analyzes ions before fragmentation. Depending on MS inlet conditions, DMS-selected ions can be dissociated in the MS inlet expansion, before mass analysis, providing a capability similar to MS/MS with simpler instrumentation. This report presents selected DMS-MS experimental results, including resolution of complex test mixtures of isobaric compounds, separation of charge states, separation of isobaric biomarkers (citrate and isocitrate), and separation of nearly isobaric biomarker anions in direct analysis of a bio-fluid sample from the radiation-treated group of a mouse-model study. These uses of DMS combined with moderate resolution MS instrumentation indicate the feasibility of field-deployable instrumentation for biomarker evaluation. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:108 / 117
页数:10
相关论文
共 30 条
  • [1] [Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
  • [2] IDENTIFICATION OF N-HEXANOYLGLYCINE IN URINES FROM 2 PATIENTS WITH JAMAICAN VOMITING SICKNESS
    BARETZ, BH
    RAMSDELL, HS
    TANAKA, K
    [J]. CLINICA CHIMICA ACTA, 1976, 73 (01) : 199 - 202
  • [3] BURYAKOV IA, 1993, ZH ANAL KHIM, V48, P114
  • [4] Metabolic profiling by ion mobility mass spectrometry (IMMS)
    Dwivedi, Prabha
    Wu, Peiying
    Klopsch, Steve J.
    Puzon, Geoffrey J.
    Xun, Luying
    Hill, Herbert H., Jr.
    [J]. METABOLOMICS, 2008, 4 (01) : 63 - 80
  • [5] Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas
    Eiceman, GA
    Krylov, EV
    Nazarov, EG
    Miller, RA
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (17) : 4937 - 4944
  • [6] GATES R, 2008, REPORT COMMISSION PR
  • [7] Guevremont R, 2005, AM LAB, V37, P11
  • [8] High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
    Guevremont, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 3 - 19
  • [9] Fragmentation pathways and mechanisms of aromatic compounds in atmospheric pressure studied by GC-DMS and DMS-MS
    Kendler, Shai
    Lambertus, Gordon R.
    Dunietz, Barry D.
    Coy, Stephen L.
    Nazarov, Erkinjon G.
    Miller, Raanan A.
    Sacks, Richard D.
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 263 (2-3) : 137 - 147
  • [10] Mechanistic investigation of ionization suppression in electrospray ionization
    King, R
    Bonfiglio, R
    Fernandez-Metzler, C
    Miller-Stein, C
    Olah, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) : 942 - 950