Feasibility of Low-volume Injections of Contrast Material with a Body Weight-Adapted Iodine-Dose Protocol in 320-Detector Row Coronary CT Angiography

被引:40
作者
Tatsugami, Fuminari [1 ]
Matsuki, Mitsuru [1 ]
Inada, Yuki [1 ]
Kanazawa, Shuji [1 ]
Nakai, Go [1 ]
Takeda, Yoshihiro [2 ]
Morita, Hideaki [3 ]
Takada, Haruhiko [1 ]
Ashida, Kenji [1 ]
Yoshikawa, Shushi [1 ]
Fukumura, Katsunori [1 ]
Narumi, Yoshifumi [1 ]
机构
[1] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 5698686, Japan
[2] Osaka Med Coll, Dept Internal Med 1, Takatsuki, Osaka 5698686, Japan
[3] Osaka Med Coll, Dept Internal Med 3, Takatsuki, Osaka 5698686, Japan
关键词
Cardiac CT; CT coronary angiography; contrast material; injection method; 320-detector row CT; SPIRAL COMPUTED-TOMOGRAPHY; PATIENT WEIGHT; MASS INDEX; ENHANCEMENT; ATTENUATION; DURATION; TIME;
D O I
10.1016/j.acra.2009.09.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate the feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in computed tomography coronary angiography (CTCA) using a 320-detector row scanner. Materials and Methods: Ninety-eight patients who underwent CTCA in a single heartbeat with electrocardiogram-gating were divided into two groups, receiving 0.8 mL/kg of contrast material injected at a fixed duration of 12 seconds (A; n = 48) or 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds (13; n = 50); all patients then received 20 mL of saline. Contrast densities were assessed for the ascending aorta, left ventricle, right coronary artery (RCA), and left main coronary artery (LMA). Results: The mean flow rate was 4.00 +/- 0.56 mL/second in group A and 4.06 +/- 0.57 mL/second in group B (P = .51). There were no significant differences in the mean enhancement values of the ascending aorta, LMA and proximal RCA between the two groups. Also, there was no significant difference between the mean enhancement values at the three different levels of the RCA (proximal, middle, and distal segments) (group A; P = .27, group B; P = .07). Conclusion: The use of 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds was feasible for CTCA using 320-detector row CT, with a sufficient and reliable contrast enhancement in the ascending aorta and coronary artery.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 22 条
  • [1] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [2] Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight
    Awai, K
    Hiraishi, K
    Hori, S
    [J]. RADIOLOGY, 2004, 230 (01) : 142 - 150
  • [3] Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity
    Bae, Kyongtae T.
    Seeck, Brian A.
    Hildebolt, Charles F.
    Tao, Cheng
    Zhu, Fang
    Kanematsu, Masayuki
    Woodard, Pamela K.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) : 777 - 784
  • [4] Clinical use of multislice spiral computed tomography in 210 highly preselected patients: experience with 4 and 16 slice technology
    Beck, T
    Burgstahler, C
    Kuettner, A
    Kopp, AF
    Heuschmid, M
    Claussen, CD
    Schroeder, S
    [J]. HEART, 2005, 91 (11) : 1423 - 1427
  • [5] Computed tomography coronary angiography with 370-millisecond gantry rotation time - Evaluation of the best image reconstruction interval
    Bley, TA
    Ghanem, NA
    Foell, D
    Uhl, M
    Geibel, A
    Bode, C
    Langer, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) : 1 - 5
  • [6] Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation
    Cademartiri, F
    Mollet, NR
    van der Lugt, A
    McFadden, EP
    Stijnen, T
    de Feyter, PJ
    Krestin, GP
    [J]. RADIOLOGY, 2005, 236 (02) : 661 - 665
  • [7] Cademartiri Filippo, 2006, AJR Am J Roentgenol, V187, pW430, DOI 10.2214/AJR.05.1406
  • [8] Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality
    Donnino, Robert
    Jacobs, Jill E.
    Doshi, Jay V.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Babb, James S.
    Srichai, Monvadi B.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 1051 - 1056
  • [9] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [10] Multiphasic contrast-enhanced multidetector-row CT of liver: Contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material
    Ichikawa, T
    Erturk, SM
    Araki, T
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) : 165 - 176