摘要
PURPOSE: To evaluate a lung biopsy technique in which a detachable, 18-gauge, coaxial guide around a central notched stylet is used as a cutting needle. MATERIALS AND METHODS: The records of 89 consecutive patients (41 women, 48 men; aged 21-86 years) who underwent coaxial percutaneous core biopsy of 91 lung lesions that required needle passage through normal lung tissue (mean lesion size, 33.6 mm; range, 9-80 mm) were studied. Detachable, 18-guage, coaxial automated cutting needles were used. RESULTS: The mean number of needle passes was 2.5 (range, 1-4). All biopsies yielded sufficient tissue for histopathologic (n = 91) and, if necessary, bacteriologic (n = 12) evaluation (mean core length, 5 mm; range, 1-15 mm). Eighty-nine lesions had definitive diagnosis. Seventy-five lesions were proved to be malignant; seventy (93%) could be accurately diagnosed with coaxial percutaneous core biopsy samples. Fourteen lesions were proved to be benign; 10 (71%) were specifically diagnosed with biopsy samples. Among the 91 biopsies, the overall diagnostic accuracy was 88% (80 of 91 lesions). A pneumothorax occurred in 31 cases (34%), three (3%) of which necessitated placement of a chest tube. Postbiopsy hemoptysis occurred and resolved spontaneously in nine cases (10%). CONCLUSION: This technique provides a core biopsy specimen without the need for an on-site cytopathologist during the procedure. It has a high diagnostic accuracy and an acceptable rate of complications.
引用
收藏
页码:759 / 765
页数:7
相关论文
共 46 条
[1]   FATAL SYSTEMIC ARTERIAL AIR-EMBOLISM FOLLOWING LUNG NEEDLE ASPIRATION [J].
ABERLE, DR ;
GAMSU, G ;
GOLDEN, JA .
RADIOLOGY, 1987, 165 (02) :351-353
[2]   CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration [J].
Arakawa, H ;
Nakajima, Y ;
Kurihara, Y ;
Niimi, H ;
Ishikawa, T .
CLINICAL RADIOLOGY, 1996, 51 (07) :503-506
[3]   VALUE OF HAVING A CYTOPATHOLOGIST PRESENT DURING PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY OF LUNG - REPORT OF 55 CANCER-PATIENTS AND METAANALYSIS OF THE LITERATURE [J].
AUSTIN, JHM ;
COHEN, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :175-177
[4]   COMPUTED-TOMOGRAPHY OF FATAL CEREBRAL AIR-EMBOLISM FOLLOWING PERCUTANEOUS ASPIRATION BIOPSY OF THE LUNG [J].
BAKER, BK ;
AWWAD, EE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (06) :1082-1083
[5]  
BOCKING A, 1995, ACTA CYTOL, V39, P463
[6]  
BOSIELLE PM, 1997, AJR, V169, P661
[7]   IMAGE-GUIDED AUTOMATED CORE BIOPSIES OF THE BREAST, CHEST, ABDOMEN, AND PELVIS [J].
BURBANK, F ;
KAYE, K ;
BELVILLE, J ;
EKUAN, J ;
BLUMENFELD, M .
RADIOLOGY, 1994, 191 (01) :165-171
[8]   ETIOLOGIC DIAGNOSIS OF FOCAL PULMONARY INFECTION IN IMMUNOCOMPROMISED PATIENTS BY FLUOROSCOPICALLY GUIDED PERCUTANEOUS NEEDLE ASPIRATION [J].
CASTELLINO, RA ;
BLANK, N .
RADIOLOGY, 1979, 132 (03) :563-567
[9]  
CIANCI P, 1992, CHEST, V4, P749
[10]  
CROSBY JH, 1985, CANCER, V56, P2504, DOI 10.1002/1097-0142(19851115)56:10<2504::AID-CNCR2820561030>3.0.CO