Metallic renal artery MR imaging stent:: Artifact-free lumen visualization with projection and standard renal MR angiography

被引:17
|
作者
Spuentrup, E
Ruebben, A
Stuber, M
Günther, RW
Buecker, A
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Beth Israel Deaconess Med Ctr, Div Cardiovasc, Dept Med, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
[4] Philips Med Syst, Best, Netherlands
关键词
magnetic resonance (MR); artifact; vascular studies; renal arteries; MR; stenosis or obstruction; stents and prostheses;
D O I
10.1148/radiol.2273020354
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of instent restenosis. (C) RSNA, 2003.
引用
收藏
页码:897 / 902
页数:6
相关论文
共 50 条
  • [31] ABDOMINAL-AORTA AND RENAL-ARTERY STENOSIS - EVALUATION WITH MR ANGIOGRAPHY
    KIM, D
    EDELMAN, RR
    KENT, KC
    PORTER, DH
    SKILLMAN, JJ
    RADIOLOGY, 1990, 174 (03) : 727 - 731
  • [32] Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis
    Duda, SH
    Schick, F
    Teufl, F
    MullerSchimpfle, M
    Erley, C
    Schneider, W
    Miller, S
    Claussen, CD
    ACTA RADIOLOGICA, 1997, 38 (02) : 287 - 291
  • [33] Impact of screening MR angiography on management of patients with suspected renal artery stenosis
    Cay, O
    Chiang, EE
    Rabkin, DJ
    Rosen, MP
    Brophy, DP
    Edelman, RR
    RADIOLOGY, 2000, 217 : 310 - 310
  • [34] EFFECT OF FLOW DISTURBANCES ON MR-ANGIOGRAPHY IN RENAL-ARTERY STENOSIS
    ORTEGA, HV
    VINITSKI, S
    MOHAMED, FB
    OUTWATER, EK
    FARO, SH
    MITCHELL, DG
    RADIOLOGY, 1995, 197 : 187 - 187
  • [35] Comparison of conventional angiography and gadolinium-enhanced MR angiography in the evaluation of renal artery stenosis
    Gilfeather, M
    Yoon, H
    Nowers, K
    Axel, L
    Schnall, MD
    SchlanskyGoldberg, RD
    RADIOLOGY, 1997, 205 : 271 - 271
  • [36] Renal artery stenosis: Evaluation with conventional angiography versus gadolinium-enhanced MR angiography
    Gilfeather, M
    Yoon, HC
    Siegelman, ES
    Axel, L
    Stolpen, AH
    Shlansky-Goldberg, RD
    Baum, RA
    Soulen, MC
    Schnall, MD
    RADIOLOGY, 1999, 210 (02) : 367 - 372
  • [37] RENAL-ARTERY VISUALIZATION WITH MR ANGIOGRAPHIC TECHNIQUES - COMPARATIVE-STUDY
    COUSINS, JP
    PATEL, RS
    ZIRINSKY, K
    COLLINS, MB
    RADIOLOGY, 1992, 185 : 203 - 203
  • [38] Imaging of renovascular hypertension: Respective values of renal scintigraphy, renal Doppler US, and MR angiography - Commentary
    Sarkar, SD
    Siegel, DN
    RADIOGRAPHICS, 2000, 20 (05) : 1368 - 1371
  • [39] Detection of renal artery stenosis using 30 phase contrast MR angiography and dynamic perfusion imaging.
    Miller, S
    Hahn, U
    Schick, F
    Nägele, T
    Duda, SH
    Eckstein, FS
    Scheule, AM
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (02): : 163 - 167
  • [40] Diffusion-weighted MR imaging of kidneys in renal artery stenosis
    Yildirim, Erkan
    Kirbas, Ismail
    Teksam, Mehmet
    Karadeli, Elif
    Gullu, Hakan
    Ozer, Ismail
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) : 148 - 153