Radiation Exposure of Patient and Operating Room Personnel by Fluoroscopy and Navigation during Spinal Surgery

被引:63
作者
Bratschitsch, G. [1 ]
Leitner, L. [1 ]
Stuecklschweiger, G. [2 ]
Guss, H. [2 ]
Sadoghi, P. [1 ]
Puchwein, P. [1 ]
Leithner, A. [1 ]
Radl, R. [1 ]
机构
[1] Med Univ Graz, Dept Orthoped & Trauma, Graz, Austria
[2] Med Univ Graz, Competence Ctr Med Phys & Radiat Protect, Graz, Austria
关键词
PORTABLE X-RAY; INTRAOPERATIVE FLUOROSCOPY; CT PATIENT;
D O I
10.1038/s41598-019-53472-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intraoperative radiography imaging is essential for accurate spinal implant placement. Hazards caused by ionizing radiation raised concern on personnel's work life long exposure in the operating room (OR). To particularize a cumulative risk estimation of radiation of personnel and patient, depending on used methods (C-arm fluoroscopy, O-arm navigation) and patient characteristics during spinal surgery, detailed investigation of radiation exposure in a clinical setting is required. Lumbosacral dorsal spinal fusion was performed in 37 patients (19 navigated, 18 fluoroscopy) during this prospective study. Radiation exposure was measured on several body regions with thermoluminescent dosimeters on patient and OR personnel (surgeon, assistant, sterile nurse, radiology technologist). Comparison between patient characteristics and radiation exposure was included. The highest patients values were measured in the surgery field and gonads area during navigation (43.2 +/- 19.4 mSv; fluoroscopy: 27.7 +/- 31.3 mSv; p = 0.02), followed by the thoracic region during fluoroscopy (7.7 +/- 14.8 mSv; navigation: 1.1 +/- 1.0 mSv; p = 0.06), other measured regions can be considered marginal in comparison. Amongst OR personnel exposure of the surgeon was significant higher during fluoroscopy (right hand: 566 +/- 560 mu Sv and thoracic region: 275 +/- 147 mu Sv; followed by thyroid and forehead) compared to navigation (right finger: 49 +/- 19 mu Sv; similar levels for all regions; p < 0.001 in all regions). When compared to the surgeon, other OR personnel had significantly lower radiation doses on all body regions using fluoroscopy, and similar dose during navigation. The highest eye's lens region value was measured during fluoroscopy for the patient (185 +/- 165 mu Sv; navigation: 205 +/- 60 mu Sv; p = 0.57) and the surgeon (164 +/- 74 mu Sv; navigation: 92 +/- 41 mu Sv; p < 0.001). There was a significant correlation between patient BMI and radiation exposure to the surgery field during fluoroscopy. To our knowledge, these data present the first real life, detailed comparison of radiation exposure on OR personnel and patients between clinical use of navigation and fluoroscopy. Although patient's radiation dose is approximately 3-fold during navigation compared to the fluoroscopy, we found that a spinal surgeon could perform up to 10-fold number of surgeries (10.000 versus 883) until maximum permissible annual effective radiation dose would be reached. Especially for a spinal surgeon, who is mainly exposed amongst OR personnel, radiation prevention and protection must remain a main issue.
引用
收藏
页数:5
相关论文
共 15 条
  • [1] Radiation Exposure to the Surgeon During Percutaneous Endoscopic Lumbar Discectomy A Prospective Study
    Ahn, Yong
    Kim, Chang-Ho
    Lee, June Ho
    Lee, Sang-Ho
    Kim, Jin-Sung
    [J]. SPINE, 2013, 38 (07) : 617 - 625
  • [2] Unprotected Operator Eye Lens Doses in Oncologic Interventional Radiology Are Clinically Significant: Estimation from Patient Kerma-area-product Data
    Dauer, Lawrence T.
    Thornton, Raymond H.
    Solomon, Stephen B.
    St Germain, Jean
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (12) : 1859 - 1861
  • [3] Impact of body habitus on fluoroscopic radiation emission during minimally invasive spine surgery
    Kukreja, Sunil
    Heydel, Justin
    Nanda, Anil
    Sin, Anthony H.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) : 211 - 218
  • [4] Cancer risks associated with external radiation from diagnostic imaging procedures
    Linet, Martha S.
    Slovis, Thomas L.
    Miller, Donald L.
    Kleinerman, Ruth
    Lee, Choonsik
    Rajaraman, Preetha
    de Gonzalez, Amy Berrington
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 2012, 62 (02) : 75 - 100
  • [5] Increased cancer risk among surgeons in an orthopaedic hospital
    Mastrangelo, G
    Fedeli, U
    Fadda, E
    Giovanazzi, A
    Scoizzato, L
    Saia, B
    [J]. OCCUPATIONAL MEDICINE-OXFORD, 2005, 55 (06): : 498 - 500
  • [6] Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation
    Mendelsohn, Daniel
    Strelzow, Jason
    Dea, Nicolas
    Ford, Nancy L.
    Batke, Juliet
    Pennington, Andrew
    Yang, Kaiyun
    Ailon, Tamir
    Boyd, Michael
    Dvorak, Marcel
    Kwon, Brian
    Paquette, Scott
    Fisher, Charles
    Street, John
    [J]. SPINE JOURNAL, 2016, 16 (03) : 343 - 354
  • [7] Radiation Exposure to the Surgeon During Percutaneous Pedicle Screw Placement
    Mroz, Thomas E.
    Abdullah, Kalil G.
    Steinmetz, Michael P.
    Klineberg, Eric O.
    Lieberman, Isador H.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (04): : 264 - 267
  • [8] Intraoperative fluoroscopy, portable X-ray, and CT: patient and operating room personnel radiation exposure in spinal surgery
    Nelson, Elisha M.
    Monazzam, Shafagh M.
    Kim, Kee D.
    Seibert, J. Anthony
    Klineberg, Eric O.
    [J]. SPINE JOURNAL, 2014, 14 (12) : 2985 - 2991
  • [9] Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging Technical note
    Oertel, Matthias F.
    Hobart, Juliane
    Stein, Marco
    Schreiber, Vanessa
    Scharbrodt, Wolfram
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (04) : 532 - 536
  • [10] Commentary on: Intraoperative fluoroscopy, portable X-ray, and CT: patient and operating room personnel radiation exposure in spinal surgery
    Prasarn, Mark L.
    [J]. SPINE JOURNAL, 2014, 14 (12) : 2992 - 2994