Sensitivity and specificity of human brain glutathione concentrations measured using short-TE 1H MRS at 7 T

被引:29
作者
Deelchand, Dinesh K. [1 ]
Marjanska, Malgorzata [1 ]
Hodges, James S. [2 ]
Terpstra, Melissa [1 ]
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, 2021 6th St SE, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Div Biostat, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
GSH; antioxidant; MRS; LCModel; STEAM; IN-VIVO; H-1-NMR SPECTROSCOPY; SPECTRA; QUANTIFICATION; TESLA; ARRAY; FIELD; COIL;
D O I
10.1002/nbm.3507
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although the MR editing techniques that have traditionally been used for the measurement of glutathione (GSH) concentrations in vivo address the problem of spectral overlap, they suffer detriments associated with inherently long TEs. The purpose of this study was to characterize the sensitivity and specificity for the quantification of GSH concentrations without editing at short TE. The approach was to measure synthetically generated changes in GSH concentrations from in vivo stimulated echo acquisition mode (STEAM) spectra after in vitro GSH spectra had been added to or subtracted from them. Spectra from five test subjects were synthetically altered to mimic changes in the GSH signal. To account for different background noise between measurements, retest spectra (from the same individuals as used to generate the altered data) and spectra from five other individuals were compared with the synthetically altered spectra to investigate the reliability of the quantification of GSH concentration. Using STEAM spectroscopy at 7 T, GSH concentration differences on the order of 20% were detected between test and retest studies, as well as between differing populations in a small sample (n = 5) with high accuracy (R-2 > 0.99) and certainty (p 0.01). Both increases and decreases in GSH concentration were reliably quantified with small impact on the quantification of ascorbate and -aminobutyric acid. These results show the feasibility of using short-TE H-1 MRS to measure biologically relevant changes and differences in human brain GSH concentration. Although these outcomes are specific to the experimental approach used and the spectral quality achieved, this study serves as a template for the analogous scrutiny of quantification reliability for other compounds, methodologies and spectral qualities. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:600 / 606
页数:7
相关论文
共 30 条
  • [1] A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla
    Adriany, Gregor
    De Moortele, Pierre-Francois Van
    Ritter, Johannes
    Moeller, Steen
    Auerbach, Edward J.
    Akguen, Can
    Snyder, Carl J.
    Vaughan, Thomas
    Ugurbill, Kamil
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 590 - 597
  • [2] MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN
    BRANTZAWADZKI, M
    GILLAN, GD
    NITZ, WR
    [J]. RADIOLOGY, 1992, 182 (03) : 769 - 775
  • [3] Brain Region-Specific Glutathione Redox Imbalance in Autism
    Chauhan, Abha
    Audhya, Tapan
    Chauhan, Ved
    [J]. NEUROCHEMICAL RESEARCH, 2012, 37 (08) : 1681 - 1689
  • [4] Measurement of glutathione in human brain at 3T using an improved double quantum filter in vivo
    Choi, Changho
    Zhao, Chenguang
    Dimitrov, Ivan
    Douglas, Deborah
    Coupland, Nicholas J.
    Kalra, Sanjay
    Hawesa, Halima
    Davis, Jeannie
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2009, 198 (02) : 160 - 166
  • [5] Dairy intake is associated with brain glutathione concentration in older adults
    Choi, In-Young
    Lee, Phil
    Denney, Douglas R.
    Spaeth, Kendra
    Nast, Olivia
    Ptomey, Lauren
    Roth, Alexandra K.
    Lierman, Jo Ann
    Sullivan, Debra K.
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2015, 101 (02) : 287 - 293
  • [6] Improved Quantification Precision of Human Brain Short Echo-Time 1H Magnetic Resonance Spectroscopy at High Magnetic Field: A Simulation Study
    Deelchand, Dinesh Kumar
    Iltis, Isabelle
    Henry, Pierre-Gilles
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 20 - 25
  • [7] Metabolism and functions of glutathione in brain
    Dringen, R
    [J]. PROGRESS IN NEUROBIOLOGY, 2000, 62 (06) : 649 - 671
  • [8] Noninvasive quantification of ascorbate and glutathione concentration in the elderly human brain
    Emir, Uzay E.
    Raatz, Susan
    McPherson, Susan
    Hodges, James S.
    Torkelson, Carolyn
    Tawfik, Pierre
    White, Tonya
    Terpstra, Melissa
    [J]. NMR IN BIOMEDICINE, 2011, 24 (07) : 888 - 894
  • [9] Whole brain segmentation: Automated labeling of neuroanatomical structures in the human brain
    Fischl, B
    Salat, DH
    Busa, E
    Albert, M
    Dieterich, M
    Haselgrove, C
    van der Kouwe, A
    Killiany, R
    Kennedy, D
    Klaveness, S
    Montillo, A
    Makris, N
    Rosen, B
    Dale, AM
    [J]. NEURON, 2002, 33 (03) : 341 - 355
  • [10] LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES