On the Minimal Adequate Sampling Frequency of the Photoplethysmogram for Pulse Rate Monitoring and Heart Rate Variability Analysis in Mobile and Wearable Technology

被引:25
|
作者
Beres, Szabolcs [1 ]
Holczer, Lorine [1 ]
Hejjel, Laszlo [1 ]
机构
[1] Univ Pecs, Med Fac, Heart Inst, Ifjusag Str 13, H-7624 Pecs, Hungary
来源
MEASUREMENT SCIENCE REVIEW | 2019年 / 19卷 / 05期
关键词
Photoplethysmography; heart rate variability; sampling frequency; spline interpolation; wearable health; VALIDATION;
D O I
10.2478/msr-2019-0030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently there has been great interest in photoplethysmogram signal processing. However, its minimally necessary sampling frequency for accurate heart rate variability parameters is ambiguous. In the present paper frequency-modulated 1.067 Hz cosine wave modelled the variable PPG in silico. The five-minute-long, 1 ms resolution master-signals were decimated (D) at 2-500 ms, then cubic spline interpolated (I) back to 1 ms resolution. The mean pulse rate, standard deviation, root mean square of successive pulse rate differences (RMSSD), and spectral components were computed by Varian 2.3 and compared to the master-series via relative accuracy error. Also Poincare-plot morphology was assessed. Mean pulse rate is accurate down to 303 ms (D) and 400 ms (I). In low-variability series standard deviation required at least 5 ms (D) and 100 ms (I). RMSSD needed 10 ms (D), and 303 ms (I) in normal, whereas 2 ms (D) and 100 ms (I) in low-variability series. In the frequency domain 5 ms (D) and 100 ms (I) are required. 2 ms (D) and 100 ms (I) preserved the Poincare-plot morphology. The minimal sampling frequency of PPG for accurate HRV analysis is higher than expected from the signal bandwidth and sampling theorem. Interpolation improves accuracy. The ratio of sampling error and expected variability should be considered besides the inherent sensitivity of the given parameter, the interpolation technique, and the pulse rate detection method.
引用
收藏
页码:232 / 240
页数:9
相关论文
共 50 条
  • [1] The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteers
    Beres, Szabolcs
    Hejjel, Laszlo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 68
  • [2] Sampling Rate Reduction for Wearable Heart Rate Variability Monitoring
    Nishikawa, Yuki
    Izumi, Shintaro
    Yano, Yuji
    Kawaguchi, Hiroshi
    Yoshimoto, Masahiko
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [3] An effect of sampling rate to the time and frequency domain analysis of pulse rate variability
    Yang Y.L.
    Shin H.
    Shin, Hangsik (hangsik.shin@jnu.ac.kr), 1600, Korean Institute of Electrical Engineers (65): : 1247 - 1251
  • [4] Heart Rate Variability and Pulse Rate Variability: Do Anatomical Location and Sampling Rate Matter?
    Burma, Joel S.
    Griffiths, James K.
    Lapointe, Andrew P.
    Oni, Ibukunoluwa K.
    Soroush, Ateyeh
    Carere, Joseph
    Smirl, Jonathan D.
    Dunn, Jeff F.
    SENSORS, 2024, 24 (07)
  • [5] On the Reliability of Wearable Technology: A Tutorial on Measuring Heart Rate and Heart Rate Variability in the Wild
    Dudarev, Veronica
    Barral, Oswald
    Zhang, Chuxuan
    Davis, Guy
    Enns, James T.
    SENSORS, 2023, 23 (13)
  • [6] Heart Rate Variability Duration: Expanding the Ability of Wearable Technology to Improve Outpatient Monitoring?
    Sheridan, David C.
    Domingo, Karyssa N.
    Dehart, Ryan
    Baker, Steven D.
    FRONTIERS IN PSYCHIATRY, 2021, 12
  • [7] Electrocardiogram Sampling Frequency Range Acceptable for Heart Rate Variability Analysis
    Kwon, Ohhwan
    Jeong, Jinwoo
    Kim, Hyung Bin
    Kwon, In Ho
    Park, Song Yi
    Kim, Ji Eun
    Choi, Yuri
    HEALTHCARE INFORMATICS RESEARCH, 2018, 24 (03) : 198 - 206
  • [8] Statistical analysis of pulse rate variability quantified through second derivative photoplethysmogram (SDPPG) and its compatibility with electrocardiographic (ECG) heart rate variability
    Mohanalakshmi, S.
    Sivasubramanian, A.
    Swarnalatha, A.
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (02): : 689 - 694
  • [9] Reducing Motion Artifacts of Pulse Intervals from Photoplethysmogram of a Commercial Wristband for Heart Rate Variability Analysis
    Wang, Hui
    Jimison, Holly
    Pavel, Misha
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 47 - 51
  • [10] Effect of EKG Sampling Rate on Heart Rate Variability Analysis
    Govindan, R. B.
    Massaro, An N.
    Kota, Srinivas
    Grabowski, Reagan C.
    Wilson, James D.
    du Plessis, Adre
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6780 - 6783