ANALYSIS OF PATIENT SETUP UNCERTAINTIES BY USING IN-TREATMENT CONE-BEAM CT FOR PROSTATE CANCER

被引:0
作者
Shiraishi, K. [1 ]
Haga, A. [1 ]
Katsutake, S. [1 ]
Saotome, N. [1 ]
Kida, S. [1 ]
Sakumi, A. [1 ]
Onoe, T. [1 ]
Yamamoto, K. [1 ]
Ohtomo, K. [1 ]
Keiichi, N. [1 ]
机构
[1] Univ Tokyo Hosp, Dept Radiol, Tokyo, Japan
关键词
D O I
10.1016/S0167-8140(11)71388-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1266
引用
收藏
页码:S472 / S472
页数:1
相关论文
共 50 条
[21]   An analysis of cone-beam CT for determining setup errors and designing treatment margins for non-small cell lung cancer patients [J].
Wong, T. ;
Ye, J. ;
Cao, D. ;
Shepard, D. ;
Mehta, V. .
MEDICAL PHYSICS, 2007, 34 (06) :2369-2370
[22]   Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients [J].
Létourneau, D ;
Martinez, AA ;
Lockman, D ;
Yan, D ;
Vargas, C ;
Ivaldi, G ;
Wong, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1239-1246
[23]   Can Fiducial Marker-Based Setup Using ExacTrac Be An Alternative to Soft Tissue-Based Setup Using Cone-Beam CT for Prostate IMRT? [J].
Tanabe, S. ;
Utsunomiya, S. ;
Abe, E. ;
Satou, H. ;
Sakai, H. ;
Yamada, T. ;
Aoyama, H. .
MEDICAL PHYSICS, 2015, 42 (06) :3268-3269
[24]   IN-TREATMENT DOSE CALCULATION USING INTREATMENT 4D KILOVOLTAGE CONE-BEAM CT AND IN-TREATMENT LINAC PARAMETERS DURING VOLUMETRIC MODULATED ARC THERAPY FOR A LUNG TUMOR [J].
Sakumi, A. ;
Haga, A. ;
Satoshi, K. ;
Naoya, S. ;
Yoda, K. ;
Nakagawa, K. .
RADIOTHERAPY AND ONCOLOGY, 2012, 102 :S125-S125
[25]   Adaptive Radiotherapy in Cervical Cancer: Dosimetric Analysis using Daily Cone-beam CT [J].
Lawson, J. D. ;
Simpson, D. R. ;
Rose, B. S. ;
Nath, S. K. ;
Cornell, M. ;
Mundt, A. J. ;
Mell, L. K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :S85-S86
[26]   Evaluation of Automatic Volume Match Function for Kilovoltage Cone-Beam CT (CBCT) Guided Patient Setup [J].
Cao, M. ;
Cardenes, H. ;
Langer, M. ;
Slessinger, E. ;
Zhao, Q. ;
DesRosiers, C. .
MEDICAL PHYSICS, 2008, 35 (06) :2990-+
[27]   Residual Patient Setup Error in Prostate Radiation Therapy using Cone-Beam CT after Fiducial-based Alignment with kV On-board Imaging [J].
Clancy, P. E. ;
Patel, S. ;
Daniels, J. ;
Tao, W. ;
Willins, J. ;
Schuller, B. ;
Hirsch, A. E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03) :S343-S343
[28]   INITIAL DETERMINATION OF SETUP ERRORS USING DAILY CONE-BEAM CT REDUCES SUBSEQUENT VARIATION OVER A LUNG CANCER RADIOTHERAPY TREATMENT COURSE [J].
Yom, Sue S. ;
Chen, Josephine ;
Aubin, Michele ;
Morin, Olivier ;
Graff, Pierre ;
Descovich, Martina ;
Pouliot, Jean .
JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) :S830-S830
[29]   Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images [J].
Guerrero, Maria Eugenia ;
Noriega, Jorge ;
Castro, Carmen ;
Jacobs, Reinhilde .
IMAGING SCIENCE IN DENTISTRY, 2014, 44 (02) :121-128
[30]   Optimization of Image Acquisition Parameters for Patient Setup Using Megavoltage Cone-Beam Digital Tomosynthesis [J].
Descovich, M. ;
Kanner, M. ;
Morin, O. ;
Faddegon, B. ;
Cheung, J. ;
Sawkey, D. ;
Aubin, M. ;
Maltz, J. ;
Bani-Hashemi, A. ;
Pouliot, J. .
MEDICAL PHYSICS, 2009, 36 (06)