Detection limit calculations for peak evaluation methods in HPGe gamma-ray spectrometry according to ISO 11929

被引:4
作者
Kanisch, Guenter [1 ,2 ]
机构
[1] Thunen Inst Fisheries Ecol Hamburg, Hamburg, Germany
[2] Wittland 44 G, D-22589 Hamburg, Germany
关键词
Background step function; Single peak fitting; Monte Carlo simulation; Penalized least squares; Poisson MLE; ISO 11929(2010); SPECTRUM ANALYSIS; CHI-SQUARE; PART I; IDENTIFICATION; COUNT;
D O I
10.1016/j.nima.2017.02.092
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two peak area estimation methods in gamma-ray spectrometry, the total peak area (TPA) and the background step function (BSF) methods are re-considered first. For least-squares (LS) peak fitting then, a new net peak area uncertainty model is established. It results in a new function f(B) replacing a TPA method internal design factor. This allows applying the TPA-related decision threshold (DT) and detection limit (DL) formulae, based on ISO 11929(2010), also for peak fitting. Linear LS adapted to Poisson counting data is suggested to derive fB values for a single peak and different combinations of background shape components including a fitted BSF. f(B), is then adapted to penalized non-linear fitting including Poisson maximum likelihood estimation by MC simulations. Within the DL iteration the fB method is much faster than with non-linear re-fitting. The fitted peak area uncertainty can be safely modeled for peak areas up to 10 DT which is sufficient for DL calculations. The extension for peak multiplets is indicated.
引用
收藏
页码:118 / 132
页数:15
相关论文
共 48 条
[41]   HyperLab:: A new concept in gamma-ray spectrum analysis [J].
Simonits, A ;
Östör, J ;
Kálvin, S ;
Fazekas, B .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 257 (03) :589-595
[42]  
Sivia D., 2006, DATA ANAL BAYESIAN T
[43]   Evaluation of eight decision rules for low-level radioactivity counting [J].
Strom, DJ ;
MacLellan, JA .
HEALTH PHYSICS, 2001, 81 (01) :27-34
[44]   CUTIPIE - COMPUTER-PROGRAM TO ANALYZE GAMMA-RAY SPECTRA [J].
TEOH, W .
NUCLEAR INSTRUMENTS & METHODS, 1973, 109 (03) :509-513
[45]   Peak fitting and identification software library for high resolution gamma-ray spectra [J].
Uher, Josef ;
Roach, Greg ;
Tickner, James .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) :457-459
[46]   Optimization of the decision threshold for single radioactive counting [J].
Vivier, A. ;
Aupiais, J. .
RADIOCHIMICA ACTA, 2007, 95 (08) :477-492
[47]   MULTIPARAMETER LINEAR LEAST-SQUARES FITTING TO POISSON DATA ONE COUNT AT A TIME [J].
WHEATON, WA ;
DUNKLEE, AL ;
JACOBSON, AS ;
LING, JC ;
MAHONEY, WA ;
RADOCINSKI, RG .
ASTROPHYSICAL JOURNAL, 1995, 438 (01) :322-340
[48]   Statistical analysis of uncertainties of gamma-peak identification and area calculation in particulate air-filter environment radionuclide measurements using the results of a Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) organized intercomparison, Part I:: Assessment of reliability and uncertainties of isotope detection and energy precision using artificial spiked test spectra, Part II:: Assessment of the true type I error rate and the quality of peak area estimators in relation to type II errors using large numbers of natural spectra [J].
Zhang, W. ;
Zaehringer, M. ;
Ungar, K. ;
Hoffman, I. .
APPLIED RADIATION AND ISOTOPES, 2008, 66 (11) :1695-1701