Retrograde Closure of Perimembranous Ventricular Septal Defect Using Muscular Ventricular Septal Occluder: A Single-Center Experience of a Novel Technique

被引:8
作者
Muthusamy, Kalyanasundaram [1 ]
机构
[1] G Kuppuswamy Naidu Mem Hosp, Coimbatore, Tamil Nadu, India
关键词
Ventricular septal defect; Amplatzer muscular VSD device; Cera Lifetech muscular VSD device; Antegrade technique; Retrograde technique; Arteriovenous looping; MEMBRANOUS VSD OCCLUDER; TRANSCATHETER CLOSURE; AMPLATZER DEVICE; PERCUTANEOUS CLOSURE; FOLLOW-UP;
D O I
10.1007/s00246-014-0971-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We herein report the advantages of retrograde ventricular septal defect (VSD) closure using a muscular VSD device for perimembranous VSDs. Perimembranous VSDs are conventionally closed by an antegrade technique (arteriovenous looping technique) using a patent ductus arteriosus or asymmetric perimembranous VSD device. However, we used a symmetrical muscular VSD device in all cases described in this report. Use of the antegrade technique for the first few patients with VSD resulted in prolonged procedural and fluoroscopic times and frequent slippage of the device into the right ventricle. Subsequent use of the retrograde technique shortened the procedural time and allowed for easier closure of the perimembranous VSD. We performed retrograde closure of perimembranous VSDs using a symmetrical muscular VSD device in 130 patients. We obtained a high rate of successful deployment (88.5 %) and a low rate of complications (6.0 %). We also achieved shorter procedural and fluoroscopic times than those associated with the antegrade technique.
引用
收藏
页码:106 / 110
页数:5
相关论文
共 14 条
[1]   Initial human experience with the Amplatzer perimembranous ventricular septal occluder device [J].
Bass, JL ;
Kalra, GS ;
Arora, R ;
Masura, J ;
Gavora, P ;
Thanopoulos, BD ;
Torres, W ;
Sievert, H ;
Carminati, M ;
Fischer, G ;
Ewert, P .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) :238-245
[2]   Transcatheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder - Results of the US phase I trial [J].
Fu, YC ;
Bass, J ;
Amin, Z ;
Radtke, W ;
Cheatham, JP ;
Hellenbrand, WE ;
Balzer, D ;
Cao, QL ;
Hijazi, ZM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (02) :319-325
[3]  
Gu XP, 2000, CATHETER CARDIO INTE, V50, P502, DOI 10.1002/1522-726X(200008)50:4<502::AID-CCD29>3.3.CO
[4]  
2-#
[5]   Catheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder: Initial clinical experience [J].
Hijazi, ZM ;
Hakim, F ;
Abu Haweleh, A ;
Madani, A ;
Tarawna, W ;
Hiari, A ;
Cao, OL .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) :508-515
[6]   Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: Immediate and midterm results of an international registry [J].
Holzer, Ralf ;
de Giovanni, Jo ;
Walsh, Kevin P. ;
Tometzki, Andrew ;
Goh, T. H. ;
Hakim, Fakhri ;
Zabal, Carlos ;
de Lezo, Jose Suarez ;
Cao, Qi-Ling ;
Hijazi, Ziyad M. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (04) :620-628
[7]  
Kramoh E, 2008, J INVASIVE CARDIOL, V20, P212
[8]   Percutaneous closure of perimembranous ventricular septal defects with the eccentric amplatzer device: Multicenter follow-up study [J].
Masura, J ;
Gao, W ;
Gavora, P ;
Sun, K ;
Zhou, AQ ;
Jiang, S ;
Ting-Liang, L ;
Wang, Y .
PEDIATRIC CARDIOLOGY, 2005, 26 (03) :216-219
[9]  
Miro J, 2005, PED INT CARD S EM NE
[10]   Percutaneous closure of perimembranous ventricular septal defects with the amplatzer device: Technical and morphological considerations [J].
Pedra, CAC ;
Pedra, SRF ;
Esteves, CA ;
Pontes, SC ;
Braga, SLN ;
Arrieta, SR ;
Santana, MVT ;
Fontes, VF ;
Masura, J .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (03) :403-410