An amperometric solid-state NO2 sensor with a solid polymer electrolyte and a reticulated vitreous carbon indicator electrode

被引:35
作者
Hrncírová, P [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, Prague 12840 2, Czech Republic
关键词
nitrogen dioxide; reticulated vitreous carbon; solid-state sensor; solid polymer electrolyte;
D O I
10.1016/S0925-4005(00)00540-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reticulated vitreous carbon (RVC) was tested as a material for the preparation of the indicator electrode in solid-state gas sensors. The test planar sensor contained a RVC indicator, a platinum auxiliary and a Pt/air reference electrode, with a solid polymer electrolyte (SPE) of 10% PVC, 3% tetrabutylammonium hexafluorophosphate (TBAHFP) and 87% of 2-nitrophenyloctyl ether (NPOE). The analyte, gaseous nitrogen dioxide in air, was monitored by reduction at - 500 mV vs. the Pt/air electrode. The reduction current was linearly dependent on the analyte concentration over the whole test range, from 0.2 to 2.2 ppm (v/v). The sensitivity of determination amounted to 277 nA/ppm, the limit of detection was 80 ppb (at a relative humidity, RH, of 54%) and 90% of the steady-state signal was attained within 19 s. The measuring sensitivity depended on the temperature, the gas flow rate and the RH with slopes of 1.04% per 1 degrees C, 32% per 1 ml/s and 0.16% per 1% RH, respectively. It has been demonstrated that RVC can successfully replace noble metals in gas solid-state sensors. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 19 条
[1]   THE VOLTAMMETRY OF SOME OXIDIZING AND REDUCING TOXIC GASES DIRECT FROM THE GAS-PHASE, AT GOLD AND PLATINUM METALLIZED-MEMBRANE ELECTRODES IN ACID AND ALKALI [J].
BERGMAN, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 157 (01) :59-73
[2]   AN INTEGRATED AMPEROMETRIC MICROSENSOR [J].
BUTTNER, WJ ;
MACLAY, GJ ;
STETTER, JR .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :303-307
[3]  
BUTTNER WJ, 1990, SENSOR MATER, V2, P99
[4]   ELECTROCHEMICAL NO2 GAS SENSORS - MODEL AND MECHANISM FOR THE ELECTROREDUCTION OF NO2 [J].
CHANG, SC ;
STETTER, JR .
ELECTROANALYSIS, 1990, 2 (05) :359-365
[5]   Electrochemical nitrogen dioxide gas sensor based on solid polymeric electrolyte [J].
Do, JS ;
Shieh, RY .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 37 (1-2) :19-26
[6]  
LACONTI AB, 1981, ACS SYM SER, V149, P551
[7]   Amperometric solid-state NO2 sensor based on plasticized PVC matrix containing a hydrophobic electrolyte [J].
Langmaier, J ;
Opekar, F ;
Samec, Z .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) :1-6
[8]   MICROFABRICATED AMPEROMETRIC GAS SENSORS [J].
MACLAY, GJ ;
BUTTNER, WJ ;
STETTER, JR .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1988, 35 (06) :793-799
[9]   OPTICALLY TRANSPARENT VITREOUS CARBON ELECTRODE [J].
NORVELL, VE ;
MAMANTOV, G .
ANALYTICAL CHEMISTRY, 1977, 49 (09) :1470-1472
[10]   LIFE TIME OF NEUTRAL CARRIER BASED ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES [J].
OESCH, U ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1980, 52 (04) :692-700