Characterization of left atrium and distal pulmonary vein morphology using multidimensional computed tomography

被引:214
作者
Schwartzman, D
Lacomis, J
Wigginton, WG
机构
[1] Univ Pittsburgh, Atrial Arrhythmia Ctr, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA USA
关键词
D O I
10.1016/S0735-1097(03)00124-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was designed to examine the dimensions and morphology of left atrial (LA) and distal pulmonary veins (PVs) using multidetector helical computed tomography (MDCT). BACKGROUND Detailed knowledge of LA and PV anatomy will assist in the development of techniques for ablative intervention. Multidetector helical computed tomography is a method for multidimensional imaging of cardiac anatomy. METHODS, Multidetector helical computed tomography was used to image the LA and PVs in 70 subjects with and 47 subjects without atrial fibrillation (AF). Accuracy of the MDCT data was confirmed by correlation with echocardiography and endocardial electrogram recordings. RESULTS Left atrial and PV dimensions were significantly larger in AF versus non-AF subjects, men versus women, and subjects with persistent versus paroxysmal AF. There were no differences between groups in morphologic detail. CONCLUSIONS Multidetector helical computed tomography images of the LA and PVs are accurate and provide detailed anatomic information. Significant differences in dimensions but not morphologic detail were apparent between groups. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:1349 / 1357
页数:9
相关论文
共 7 条
  • [1] Three-dimensional volume rendering of spiral CT data: Theory and method
    Calhoun, PS
    Kuszyk, BS
    Heath, DG
    Carley, JC
    Fishman, EK
    [J]. RADIOGRAPHICS, 1999, 19 (03) : 745 - 764
  • [2] Pulmonary vein morphology in patients with paroxysmal atrial fibrillation initiated by ectopic beats originating from the pulmonary veins - Implications for catheter ablation
    Lin, WS
    Prakash, VS
    Tai, CT
    Hsieh, MH
    Tsai, CF
    Yu, WC
    Lin, YK
    Ding, YA
    Chang, MS
    Chen, SA
    [J]. CIRCULATION, 2000, 101 (11) : 1274 - 1281
  • [3] Intracardiac phased-array imaging: Methods and initial clinical experience with high resolution, under blood visualization - Initial experience with intracardiac phased-array ultrasound
    Packer, DL
    Stevens, CL
    Curley, MG
    Bruce, CJ
    Miller, FA
    Khandheria, BK
    Oh, JK
    Sinak, LJ
    Seward, JB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) : 509 - 516
  • [4] Imaging technique and clinical utility for electrophysiologic procedures of lower frequency (9 MHz) intracardiac echocardiograph
    Ren, JF
    Schwartzman, D
    Callans, D
    Marchlinski, FE
    Gottlieb, CD
    Chaudhry, FA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (12) : 1557 - +
  • [5] Premature depolarization concealed in two pulmonary veins
    Schwartzman, D
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (08) : 931 - 934
  • [6] Three-dimensional computed tomography of the pulmonary veins
    Tada, H
    Oral, H
    Knight, BP
    Morady, F
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) : 521 - 521
  • [7] Pulmonary vein dilation in patients with atrial fibrillation: Detection by magnetic resonance imaging
    Tsao, HM
    Yu, WC
    Cheng, HC
    Wu, MH
    Tai, CT
    Lin, WS
    Ding, YA
    Chang, MS
    Chen, SA
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (07) : 809 - 813