Design of 1300 nm spectral domain optical coherence tomography angiography system for iris microvascular imaging

被引:13
|
作者
Lan, Gongpu [1 ,2 ,3 ]
Xu, Jingjiang [1 ,2 ,3 ]
Hu, Zhilin [4 ]
Huang, Yanping [1 ,2 ,3 ]
Wei, Yingzhao [5 ]
Yuan, Xing [5 ]
Liu, Huazong [5 ]
Qin, Jia [1 ,2 ,3 ]
Wang, Yicheng [5 ]
Shi, Qun [5 ]
Zeng, Jun [6 ]
Shi, Yue [1 ]
Feng, Jinping [7 ]
Tan, Haishu [1 ,3 ]
An, Lin [1 ,2 ,3 ]
Wei, Xunbin [1 ,8 ,9 ,10 ]
机构
[1] Foshan Univ, Sch Phys & Optoelect Engn, Foshan 528000, Guangdong, Peoples R China
[2] Guangdong Weiren Meditech Co Ltd, Innovat & Entrepreneurship Team, Guangdong Pearl River Talents Program, Foshan 528000, Guangdong, Peoples R China
[3] Foshan Univ, Guangdong Hong Kong Macao Intelligent Micronano O, Foshan 528000, Guangdong, Peoples R China
[4] Pharostek, Rochester, MN 55901 USA
[5] Foshan Univ, Sch Mechatron Engn & Automat, Foshan 528000, Guangdong, Peoples R China
[6] First Peoples Hosp Foshan, Foshan 528000, Guangdong, Peoples R China
[7] Hubei Univ Sci & Technol, Inst Engn & Technol, Xianning 437100, Hubei, Peoples R China
[8] Peking Univ, Biomed Engn Dept, Beijing 100081, Peoples R China
[9] Peking Univ, Canc Hosp & Inst, Key Lab Carcinogenesis & Translat Res, Beijing 100142, Peoples R China
[10] Shanghai Jiao Tong Univ, State Key Lab Oncogenes & Related Genes, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金;
关键词
optical coherence tomography angiography (OCTA); human iris; microvascular imaging; linear-wavenumber spectrometer; optical design; INDOCYANINE GREEN ANGIOGRAPHY; FLUORESCEIN ANGIOGRAPHY; OCT; VASCULATURE; DEPTH; NEOVASCULARIZATION; SPECTROMETER; IMPROVEMENT; RESOLUTION; FEATURES;
D O I
10.1088/1361-6463/abf577
中图分类号
O59 [应用物理学];
学科分类号
摘要
Developing a high-resolution non-invasive optical coherence tomography angiography (OCTA) method for iris vasculature imaging is essential for diagnosing a wide range of ocular pathologies. However, the current iris-OCTA devices are still limited in imaging quality and penetration depth for dark-colored eyes ranging from brown to dark brown. A spectral domain iris-OCTA system is presented in this paper incorporating a 1300 nm wavelength for deeper tissue penetration, a linear-wavenumber spectrometer for better detection sensitivity, and an iris scan objective lens for better optical focusing across the entire iris over a 12 x 12 mm(2) scan field. The -6 dB fall-off range is similar to 3 mm, and the maximum sensitivity fall-off is -28.57 dB at 6.94 mm. The axial resolution is 15.1 +/- 3.2 mu m. The 40 mm focal-length iris scan objective is optimized based on the ocular parameters from 100 Asian participants' left eyes, and it has a diffraction-limited lateral resolution (14.14 mu m) for the iris, in general. OCT distortions were calibrated based on the average ocular parameters, and the maximum residual distortions in both the lateral and axial directions were <0.1 mm (2.0%) for all of the eyes. A pilot study on a constricted pupil was performed to demonstrate high-contrast, wide-field en face iris microvascular imaging by either a horizontal or vertical fast-scan protocol in a dark brown eye. The iris vessels are radially aligned, and each vessel is more visible when it has an angle of similar to 65 degrees-90 degrees with respect to the fast-scan direction. A new circular fast-scan protocol could improve image quality for better visualization of the iris features or integration with image-registration algorithms and an eye-tracking system for eye-motion compensation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] CHOROIDAL IMAGING USING SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Regatieri, Caio V.
    Branchini, Lauren
    Fujimoto, James G.
    Duker, Jay S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (05): : 865 - 876
  • [22] Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm
    Li, Peng
    Johnstone, Murray
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (04)
  • [23] Self-spectral calibration for spectral domain optical coherence tomography
    Zhang, Xianling
    Gao, Wanrong
    Bian, Haiyi
    Chen, Chaoliang
    Liao, Jiuling
    OPTICAL ENGINEERING, 2013, 52 (06)
  • [24] Optical coherence tomography and optical coherence tomography angiography imaging in Bietti crystalline dystrophy
    Tiryaki Demir, Semra
    Keles Yesiltas, Sumeyra
    Kacar, Hakan
    Akbas, Emine Betul
    Guven, Dilek
    OPHTHALMIC GENETICS, 2020, 41 (02) : 194 - 197
  • [25] Multirate Spectral Domain Optical Coherence Tomography
    Gaur, Prabhav
    Grieco, Andrew
    Fainman, Yeshaiahu
    IEEE PHOTONICS JOURNAL, 2023, 15 (05):
  • [26] Choroidal macrovessel: Optical coherence tomography angiography and imaging features
    Casalino, Giuseppe
    De Simone, Luca
    Scialdone, Antonio
    Pavesio, Carlos
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) : 1168 - 1170
  • [27] Optical Coherence Tomography Angiography for Anterior Segment Vasculature Imaging
    Ang, Marcus
    Sim, Dawn A.
    Keane, Pearse A.
    Sng, Chelvin C. A.
    Egan, Catherine A.
    Tufail, Adnan
    Wilkins, Mark R.
    OPHTHALMOLOGY, 2015, 122 (09) : 1740 - 1747
  • [28] Optical coherence tomography angiography and microvascular changes in diabetic retinopathy: a systematic review
    Johannesen, Sunniva Kruse
    Viken, Julie Nilssen
    Vergmann, Anna Stage
    Grauslund, Jakob
    ACTA OPHTHALMOLOGICA, 2019, 97 (01) : 7 - 14
  • [29] New Concepts in Polypoidal Choroidal Vasculopathy Imaging: A Focus on Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Teo, Kelvin Y. C.
    Cheung, Gemmy C. M.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (02): : 165 - 171
  • [30] SWEPT-SOURCE AND SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY VERSUS DYE ANGIOGRAPHY IN THE MEASUREMENT OF TYPE 1 NEOVASCULARIZATION
    Cicinelli, Maria Vittoria
    Cavalleri, Michele
    Consorte, Andrea Celestino
    Rabiolo, Alessandro
    Sacconi, Riccardo
    Bandello, Francesco
    Querques, Giuseppe
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (03): : 499 - 506