Error rates in clinical radiotherapy

被引:69
作者
Macklis, RM [1 ]
Meier, T [1 ]
Weinhous, MS [1 ]
机构
[1] Cleveland Clin Fdn, Dept Radiat Oncol T28, Cleveland, OH 44195 USA
关键词
D O I
10.1200/JCO.1998.16.2.551
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Error rates in clinical oncology are undergoing increasing scrutiny. The purpose of this study was to understand error frequency, error patterns, underlying causal links, consequences, and possible prevention strategies in clinical radiotherapy. Patients and Methods: Treatment information, self reported error documentation, and retrospective analyses of electronic treatment verification transcripts for 1,925 consecutive patients treated with a total of 93,332 individual radiotherapy fields were reviewed and analyzed. Results: A total of 59 separate errors that affected 168 individual treatment fields were detected, which yielded a crude radiation delivery error rate of 0.18%. All 59 errors were judged to be level I (negligible chance of adverse medical outcome) with the most common error category being a minor treatment field block misplacement. A comprehensive quality assurance program and an electronic record-and-verify linear accelerator interlock system seem to have prevented the occurrence of many additional errors. However, nine of the 59 errors were directly related to the use of this system and generally involved the transposition of similar numbers within series of treatment coordinate data-sets. Overall, radiotherapy error rates favorably compare with reported error rates for pharmaceutical administration in large tertiary care hospitals. Conclusion: When modern automated error-minimisation methods are used along with nonpunitive error reporting systems, clinical radiotherapy seems to be highly safe. Formal error analysis studies may allow the rational design of prevention strategies that are attuned to the frequency, seriousness, and antecedent causes of many classes of potential radiotherapy errors. (C) 1998 by American Society of Clinical Oncology.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 25 条
  • [1] ACCIDENTAL DOXORUBICIN OVERDOSAGE
    BACK, H
    GUSTAVSSON, A
    EKSBORG, S
    RODJER, S
    [J]. ACTA ONCOLOGICA, 1995, 34 (04) : 533 - 536
  • [2] ENSURING SAFETY IN THE USE OF AUTOMATED MEDICATION DISPENSING SYSTEMS
    BARKER, KN
    [J]. AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1995, 52 (21) : 2445 - 2447
  • [3] RELATIONSHIP BETWEEN MEDICATION ERRORS AND ADVERSE DRUG EVENTS
    BATES, DW
    BOYLE, DL
    VLIET, MVV
    SCHNEIDER, J
    LEAPE, L
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 1995, 10 (04) : 199 - 205
  • [4] INCIDENCE OF ADVERSE DRUG EVENTS AND POTENTIAL ADVERSE DRUG EVENTS - IMPLICATIONS FOR PREVENTION
    BATES, DW
    CULLEN, DJ
    LAIRD, N
    PETERSEN, LA
    SMALL, SD
    SERVI, D
    LAFFEL, G
    SWEITZER, BJ
    SHEA, BF
    HALLISEY, R
    VANDERVLIET, M
    NEMESKAL, R
    LEAPE, LL
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (01): : 29 - 34
  • [5] BRADY LW, 1984, CANCER TREATMENT S, V1, P1
  • [6] Cohen M R, 1996, Nursing, V26, P15
  • [7] CAN A ZERO DEFECTS PHILOSOPHY BE APPLIED TO DRUG ERRORS
    COOPER, MC
    [J]. JOURNAL OF ADVANCED NURSING, 1995, 21 (03) : 487 - 491
  • [8] THE INCIDENT REPORTING SYSTEM DOES NOT DETECT ADVERSE DRUG EVENTS - A PROBLEM FOR QUALITY IMPROVEMENT
    CULLEN, DJ
    BATES, DW
    SMALL, SD
    COOPER, JB
    NEMESKAL, AR
    LEAPE, LL
    [J]. JOINT COMMISSION JOURNAL ON QUALITY IMPROVEMENT, 1995, 21 (10): : 541 - 548
  • [9] DAVIS NM, 1994, AM J NURS, V94, P14
  • [10] COMPARISON OF MEDICATION ERRORS IN AN AMERICAN AND A BRITISH HOSPITAL
    DEAN, BS
    ALLAN, EL
    BARBER, ND
    BARKER, KN
    [J]. AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1995, 52 (22) : 2543 - 2549