Inclusion of organ deformation in dose calculations

被引:114
作者
Brock, KK [1 ]
McShan, DL
Ten Haken, RK
Hollister, SJ
Dawson, LA
Balter, JM
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
organ motion; organ deformation; dose calculations; mechanical modeling;
D O I
10.1118/1.1539039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A previously described system for modeling organ deformation using finite element analysis has been extended to permit dose calculation. Using this tool, the calculated dose to the liver during radiotherapy can be compared using a traditional static model (STATIC), a model including rigid body motion (RB), and finally a model that incorporates rigid body motion and deformation (RBD). A model of the liver, consisting of approximately 6000 tetrahedral finite elements distributed throughout the contoured volume, is created from the CT data obtained at exhale. A deformation map is then created to relate the liver in the exhale CT data to the liver in the inhale CT data. Six intermediate phase positions of each element are then calculated from their trajectories. The coordinates of the centroid of each element at each phase are used to determine the dose received. These intermediate dose values are then time weighted according to a population-modeled breathing pattern to determine the total dose to each element during treatment. This method has been tested on four patient datasets. The change in prescribed dose for each patient's actual tumor as well as a simulated tumor of the same size, located in the superior, intermediate, and inferior regions of the liver, was determined using a normal tissue complication model, maintaining a predicted probability of complications of 15%. The average change in prescribed dose from RBD to STATIC for simulated tumors in the superior, intermediate, and inferior regions are 4.0 (range 2.1 to 5.3), -3.6 (range -5.0 to -2.2), and -14.5 (range -27.0 to -10.0) Gy, respectively. The average change in prescribed dose for the patient's actual tumor was -0.4 Gy (range -4.1 to 1.7 Gy). The average change in prescribed dose from RBD to RB for simulated tumors in the superior, intermediate, and inferior regions are -0.04 (range -2.4 to 2.2), 0.2 (range -1.5 to 1.9), and 3.9 (range 0.8 to 7.3) Gy, respectively. The average change in the prescribed dose for the patient's actual tumor was 0.7 Gy (range 0.2 to 1.1 Gy). This patient sampling indicates the potential importance of including deformation in dose calculations. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 22 条
  • [1] [Anonymous], RAD RES S
  • [2] Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
    Balter, JM
    Lam, KL
    McGinn, CJ
    Lawrence, TS
    Ten Haken, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04): : 939 - 943
  • [3] Determination of ventilatory liver movement via radiographic evaluation of diaphragm position
    Balter, JM
    Dawson, LA
    Kazanjian, S
    McGinn, C
    Brock, KK
    Lawrence, T
    Ten Haken, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01): : 267 - 270
  • [4] Technical note: Creating a four-dimensional model of the liver using finite element analysis
    Brock, KK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1403 - 1405
  • [5] The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy
    Dawson, LA
    Brock, KK
    Kazanjian, S
    Fitch, D
    McGinn, CJ
    Lawrence, TS
    Ten Haken, RK
    Balter, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05): : 1410 - 1421
  • [6] Dawson LA, 2002, INT J RADIAT ONCOL, V53, P810, DOI 10.1016/S0360-3016(02)02846-8
  • [7] Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging
    Ford, EC
    Mageras, GS
    Yorke, E
    Rosenzweig, KE
    Wagman, R
    Ling, CC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (02): : 522 - 531
  • [8] A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy
    Killoran, JH
    Kooy, HM
    Gladstone, DJ
    Welte, FJ
    Beard, CJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01): : 213 - 221
  • [9] Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    Kitamura, K
    Shirato, H
    Shimizu, S
    Shinohara, N
    Harabayashi, T
    Shimizu, T
    Kodama, Y
    Endo, H
    Onimaru, R
    Nishioka, S
    Aoyama, H
    Tsuchiya, K
    Miyasaka, K
    [J]. RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) : 275 - 281
  • [10] Tissue characterization using magnetic resonance elastography: preliminary results
    Kruse, SA
    Smith, JA
    Lawrence, AJ
    Dresner, MA
    Manduca, A
    Greenleaf, JF
    Ehman, RL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) : 1579 - 1590