Contrast-enhanced Ultrasound for Detection of Crohn's Disease Activity: Systematic Review and Meta-analysis

被引:64
|
作者
Serafin, Zbigniew [1 ]
Bialecki, Marcin [1 ]
Bialecka, Agnieszka [2 ]
Sconfienza, Luca Maria [3 ,4 ]
Klopocka, Maria [5 ]
机构
[1] Nicholas Copernicus Univ, Dept Radiol & Diagnost Imaging, Coll Med, Ul M Sklodowskiej Curie 9, PL-85094 Bydgoszcz, Poland
[2] Nicholas Copernicus Univ, Dept Dermatol Sexually Transmitted Dis & Immunode, Coll Med, PL-85094 Bydgoszcz, Poland
[3] Univ Milan, IRCCS Policlin San Donato, Dept Radiol, Milan, Italy
[4] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
[5] Nicholas Copernicus Univ, Coll Med, Chair Vasc Dis & Internal Med, PL-85094 Bydgoszcz, Poland
关键词
Crohn's disease; CEUS; meta-analysis; INFLAMMATORY-BOWEL-DISEASE; TRANSABDOMINAL ULTRASONOGRAPHY; IMAGING TECHNIQUES; ACTIVITY INDEX; POWER-DOPPLER; US; ENTEROGRAPHY; SONOGRAPHY; DIAGNOSIS; ACCURACY;
D O I
10.1093/ecco-jcc/jjv196
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Reports on imaging of active Crohn's disease (aCD) using contrast-enhanced ultrasound (CEUS) are encouraging. However, the statistical power of most published papers is limited due to the small size of the patient groups included. This study was performed to verify the diagnostic value of CEUS in detecting aCD. Methods: A systematic literature search was performed by two independent reviewers for articles on the test characteristics of CEUS for the identification of aCD. The quality of the analysed studies was evaluated using a quality assessment tool for diagnostic accuracy studies (QUADAS-2). Pooling was performed using a diagnostic random-effect model and bivariate analysis. Results: Eight articles were included in the final analysis, with a total of 332 patients. There was no significant publication bias. Significant heterogeneity was found regarding CEUS methodology and sonographic definitions of aCD. In a bivariate analysis, pooled sensitivity was 0.94 (95% CI 0.87-0.97) and pooled specificity was 0.79 (95% CI 0.67-0.88). Spearman correlation statistics presented no significant diagnostic threshold effect (r = 0.12, p > 0.9). Subgroup analysis showed that relative intestine wall enhancement had the highest diagnostic value (area under the curve 94%), while the presence of enhancement and analysis of the slope were less useful (area under the curve 91 and 90%, respectively). Conclusions: CEUS presents good sensitivity and moderate specificity in the detection of the aCD. Large-scale randomized trials with quantitative evaluation of CEUS images are necessary to promote this technique in clinical practice.
引用
收藏
页码:354 / 362
页数:9
相关论文
共 50 条
  • [21] Effectiveness of contrast-enhanced ultrasound for the diagnosis of acute pancreatitis: A systematic review and meta-analysis
    Fei, Yang
    Li, Wei-qin
    DIGESTIVE AND LIVER DISEASE, 2017, 49 (06) : 623 - 629
  • [22] PERSISTENT ENHANCEMENT ON CONTRAST-ENHANCED ULTRASOUND STUDIES OF SEVERE CROHN'S DISEASE: STUCK BUBBLES?
    Wilkens, Rune
    Wilson, Alexandra
    Burns, Peter N.
    Ghosh, Subrata
    Wilson, Stephanie R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (11) : 2189 - 2198
  • [23] The Effects of Acupuncture on Crohn's Disease: a systematic review and meta-analysis
    Bae, Joon Hyun
    Kang, Seo Young
    You, Si Eun
    Jeong, Hye In
    Jang, Soobin
    Kim, Kyeong Han
    JOURNAL OF PHARMACOPUNCTURE, 2023, 26 (03) : 211 - 226
  • [24] Hospitalization of Patients with Crohn's Disease: A Systematic Review and Meta-analysis
    Niv, Yaron
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2020, 22 (02): : 111 - 115
  • [25] Diagnostic value of liver contrast-enhanced ultrasound in early hepatocellular carcinoma: a systematic review and meta-analysis
    Zhang, Zhilan
    Ma, Chunyan
    Luo, Yanbing
    JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2023, 14 (02) : 626 - 635
  • [26] Accuracy of contrast-enhanced ultrasound liver imaging reporting and data system: a systematic review and meta-analysis
    Son, Jung Hee
    Choi, Sang Hyun
    Kim, So Yeon
    Lee, So Jung
    Park, Seong Ho
    Kim, Kyung Won
    Won, Hyung Jin
    Shin, Yong Moon
    Kim, Pyo-Nyun
    HEPATOLOGY INTERNATIONAL, 2020, 14 (06) : 1104 - 1113
  • [27] Diagnosis value of focal liver lesions with SonoVueA®-enhanced ultrasound compared with contrast-enhanced computed tomography and contrast-enhanced MRI: a meta-analysis
    Guang, Yang
    Xie, LiMei
    Ding, Hailong
    Cai, AiLu
    Huang, Ying
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2011, 137 (11) : 1595 - 1605
  • [28] Diagnostic accuracy of contrast-enhanced ultrasound in the detection of small renal masses A protocol of systematic review and meta-analysis
    Wu, Jiang-feng
    Wu, Chao
    Wang, Yun-lai
    Wang, Zheng-ping
    MEDICINE, 2020, 99 (29) : E21262
  • [29] Accuracy of contrast-enhanced ultrasound in the identification of thyroid nodules: a meta-analysis
    Sun, Biyun
    Lang, Lin
    Zhu, Xiangming
    Jiang, Feng
    Hong, Yun
    He, Lianping
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 12882 - 12889
  • [30] The diagnostic performance of contrast-enhanced ultrasound versus contrast-enhanced computed tomography for pancreatic carcinoma: a systematic review and meta-analysis
    Yan, Xiaoyi
    Lv, Ke
    Xiao, Mengsu
    Tan, Li
    Gui, Yang
    Zhang, Jing
    Chen, Xueqi
    Jia, Wanying
    Li, Jinglin
    TRANSLATIONAL CANCER RESEARCH, 2022, : 3645 - 3656