A CR-39 based thermal neutron dosimeter

被引:3
|
作者
Ahmad, N
Matiullah
Kenawy, MA
机构
[1] Ctr Nucl Studies, Islamabad, Pakistan
[2] Ain Shams Univ, Univ Coll Girls, Dept Phys, Cairo, Egypt
关键词
CR-39; LiF films; activation foils; personal neutron dosimetry; vacuum coating unit; beta-gamma coincidence;
D O I
10.1016/S1350-4487(97)00111-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Both chemically and electrochemically etched CR-39 detectors are used for the detection of fast neutrons. In practical situations, fast neutrons are always accompanied by thermal neutrons. Therefore, the response of the CR-39 based dosimeter has to be extended to thermal neutrons. To do so, a radiator/converter libe LiF is introduced in front of the CR-39 detector and an optimum thickness of the LiF film is determined so that a response similar to that of the fast neutrons is achieved. Thin films of natural LiF were prepared and the response of the CR-39 detector was studied as a function of the film thickness.
引用
收藏
页码:413 / 414
页数:2
相关论文
共 50 条
  • [41] The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)
    Bolzonella, Matteo
    Caresana, Marco
    Gilvin, Philip J.
    Yukihara, Eduardo G.
    Chevallier, Marie-Anne
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1867 - 1871
  • [42] THERMAL-NEUTRON DOSIMETRY USING ELECTROCHEMICALLY ETCHED CR-39 DETECTOR
    ILIC, R
    KRISTOF, ES
    DIJANOSIC, R
    SKVARC, J
    DOBNIKAR, R
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 453 - 456
  • [43] THE INFLUENCE OF A WATER TISSUE PHANTOM ON THE RESPONSE OF A CR-39-BASED THERMAL-NEUTRON DOSIMETER
    MATIULLAH
    AHMAD, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 43 (04): : 581 - 585
  • [44] An automated neutron dosimetry system based on the chemical etch of CR-39
    Harvey, JR
    French, AP
    Jackson, M
    Renouf, MC
    Weeks, AR
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 149 - 152
  • [46] THE RESPONSE OF A CR-39 ETCH-TRACK DOSIMETER TO MODERATED AMBE AND CF-252 NEUTRON SOURCES
    NASH, AE
    JOHNSON, TL
    HEALTH PHYSICS, 1985, 49 (01): : 141 - 141
  • [47] Effect of γ rays on fast neutron registration in CR-39
    Kobzev, AP
    El-Asser, MR
    El-Halem, AA
    Abdul-Ghaphar, US
    Salama, TA
    RADIATION MEASUREMENTS, 2003, 37 (03) : 201 - 204
  • [48] Neutron dose comparison: CR-39 vs TLD
    Sengupta, S
    Holeman, G
    Kahnhauser, H
    HEALTH PHYSICS, 2002, 82 (06): : S122 - S122
  • [49] FURTHER PROGRESS TOWARDS THE CONSTRUCTION OF A CUBICAL FAST-NEUTRON DOSE EQUIVALENT DOSIMETER BASED ON THE CR-39 DETECTOR WITH FRONT RADIATORS
    MATIULLAH
    DURRANI, SA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 515 - 518
  • [50] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E
    Fantuzzi, E
    Giacomelli, G
    Giorgini, M
    Morelli, B
    Patrizii, L
    Serra, P
    Togo, V
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 437 - 442