Liquid chromatography tandem mass spectrometry assay for fast and sensitive quantification of estrone-sulfate

被引:15
作者
Corona, Giuseppe [1 ,2 ]
Elia, Caterina [2 ]
Casetta, Bruno [3 ]
Da Ponte, Alessandro [4 ]
Del Pup, Lino [5 ]
Ottavian, Enzo [6 ]
Toffoli, Giuseppe [2 ]
机构
[1] Ctr Riferimento Oncol, Natl Canc Inst, Clin & Expt Pharmacol Div, I-33081 Aviano, PN, Italy
[2] Ctr Mol Biomed, I-33081 Aviano, PN, Italy
[3] Appl Biosyst Europe, I-20052 Monza, MI, Italy
[4] Natl Canc Inst, Clin Chem & Diagnost Dept, I-33081 Aviano, PN, Italy
[5] Natl Canc Inst, Div Gynecol Oncol, I-33081 Aviano, PN, Italy
[6] Gen Hosp, Clin Pathol Lab, I-33170 Pordenone, PN, Italy
关键词
Estrone-sulfate; LC-MS/Ms; Estrogen; Menopausal; Estrogen suppression; Aromatase inhibitors; BREAST-CANCER; AROMATASE INHIBITOR; HUMAN PLASMA; ESTRADIOL; RADIOIMMUNOASSAY; EXEMESTANE; THERAPY; SERUM; RIA;
D O I
10.1016/j.cca.2010.01.019
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The circulating pool of estrone-sulfate is considered as a "reservoir" of slowly-metabolized estrogen that can be exploited for assessing overall individual estrogenicity. The aim of this study was to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry assay for the determination of estrone-sulfate, suitable for routine clinical investigations. Methods: The proposed assay is based on a simple protein precipitation procedure and on a fast measurement with a triple-quadrupole mass spectrometer operating in negative ion mode and in multiple reaction monitoring. The method was assessed for intra- and inter-day precision, accuracy, recovery, and clinical suitability. A comparison with available radioimmunoassay was also performed. Results: The LC-MS/MS method is able to detect estrone-sulfate concentrations <= 1 pg/mL and has a low limit of quantification of 7.8 pg/mL. Intra- and inter-day precision and accuracy were less than 10.5% and 5.0% respectively. The recovery was in the range of 93%-110%. When compared with radioimmunoassay the method resulted more accurate and therefore more suitable for quantifying the estrone-sulfate in different clinical settings, including patients treated with aromatase inhibitors. Conclusions: The proposed LC-MS/MS method represents a convincing alternative to the immunoassay for a fast, cost-effective and reliable measurement of estrone-sulfate in routine clinical investigations and in large epidemiological studies. It may contribute in shedding a new light on the diagnostic value of estrone-sulfate in normal and pathological conditions. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:574 / 580
页数:7
相关论文
共 20 条
  • [1] BRIND J L, 1990, Steroids, V55, P32, DOI 10.1016/0039-128X(90)90071-I
  • [2] A liquid chromatography-tandem mass spectrometry method for the simultaneous determination of exemestane and its metabolite 17-dihydroexemestane in human plasma
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Diana, Crivellari
    Rosalen, Sara
    Bari, Mario
    Toffoli, Giuseppe
    [J]. JOURNAL OF MASS SPECTROMETRY, 2009, 44 (06): : 920 - 928
  • [3] Increases in serum estrone sulfate level are associated with increased mammographic density during menopausal hormone therapy
    Crandall, Carolyn J.
    Guan, Min
    Laughlin, Gail A.
    Ursin, Giske A.
    Stanczyk, Frank Z.
    Ingles, Sue A.
    Barrett-Connor, Elizabeth
    Greendale, Gail A.
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2008, 17 (07) : 1674 - 1681
  • [4] A novel HPLC-RIA method for the simultaneous detection of estrone, estradiol and estrone sulphate levels in breast cancer tissue
    Geisler, J
    Berntsen, H
    Lonning, PE
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2000, 72 (05) : 259 - 264
  • [5] An optimised, highly sensitive radioimmunoassay for the simultaneous measurement of estrone, estradiol and estrone sulfate in the ultra-low range in human plasma samples
    Geisler, Juergen
    Ekse, Dagfinn
    Helle, Hildegunn
    Duong, Nhat Kim
    Lonning, Per Eystein
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2008, 109 (1-2) : 90 - 95
  • [6] Specific radioimmunoassay of estrone sulfate -: Application to measurement in male plasma
    Giton, F
    Valleix, A
    Boudou, P
    Villette, JM
    Bélanger, A
    Galons, H
    Fiet, J
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2002, 81 (01) : 85 - 94
  • [7] Estrone sulfate (E1S), a prognosis marker for tumor aggressiveness in prostate cancer (PCa)
    Giton, Frank
    de la Taille, Alexandre
    Allory, Yves
    Galons, Herve
    Vacherot, Francis
    Soyeux, Pascale
    Abbou, Claude Clement
    Loric, Sylvain
    Cussenot, Olivier
    Raynaud, Jean-Pierre
    Fiet, Jean
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2008, 109 (1-2) : 158 - 167
  • [8] Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization
    Guo, Tiedong
    Gu, Jianghong
    Soldin, Offie P.
    Singh, Ravinder J.
    Soldin, Steven J.
    [J]. CLINICAL BIOCHEMISTRY, 2008, 41 (09) : 736 - 741
  • [9] Exemestane, a new steroidal aromatase inhibitor of clinical relevance
    Lombardi, P
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR BASIS OF DISEASE, 2002, 1587 (2-3): : 326 - 337
  • [10] Lonning PE, 1997, J STEROID BIOCHEM, V61, P151