Determination of the lipid bilayer breakdown voltage by means of linear rising signal

被引:48
作者
Kramar, P. [1 ]
Miklavcic, D. [1 ]
Lebar, A. Macek [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, SI-1000 Ljubljana, Slovenia
关键词
lipid bilayer; linear rising signal; capacitance; breakdown voltage;
D O I
10.1016/j.bioelechem.2006.03.022
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Electroporation is characterized by formation of structural changes within the cell membrane, which are caused by the presence of electrical field. It is believed that "pores" are mostly formed in lipid bilayer structure; if so, planar lipid bilayer represents a suitable model for experimental and theoretical studies of cell membrane electroporation. The breakdown voltage of the lipid bilayer is usually determined by repeatedly applying a rectangular voltage pulse. The amplitude of the voltage pulse is incremented in small steps until the breakdown of the bilayer is obtained, Using such a protocol each bilayer is exposed to a voltage pulse many times and the number of applied voltage pulses is not known in advance. Such a pre-treatment of the lipid bilayer affects its stability and consequently the breakdown voltage of the lipid bilayer. The aim of this study is to examine an alternative approach for determination of the lipid bilayer breakdown voltage by linear rising voltage signal. Different slopes of linear rising signal have been used in our experiments (POPC lipids; folding method for forming in the salt solution of 100 mM KCl). The breakdown voltage depends on the slope of the linear rising signal. Results show that gently sloping voltage signal electroporates the lipid bilayer at a lower voltage then steep voltage signal. Linear rising signal with gentle slope can be considered as having longer pre-treatment of the lipid bilayer; thus, the corresponding breakdown voltage is lower. With decreasing the slope of linear rising signal, minimal breakdown voltage for specific lipid bilayer can be determined. Based on our results, we suggest determination of lipid bilayer breakdown voltage by linear rising signal. Better reproducibility and lower scattering are obtained due to the fact that each bilayer is exposed to electroporation treatment only once. Moreover, minimal breakdown voltage for specific lipid bilayer can be determined. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 20 条
[1]  
ABIDOR IG, 1979, BIOELECTROCH BIOENER, V6, P37
[2]   Direct visualization of electroporation-assisted in vivo gene delivery to tumors using intravital microscopy - spatial and time dependent distribution [J].
Cemazar, M ;
Wilson, I ;
Dachs, GU ;
Tozer, GM ;
Sersa, G .
BMC CANCER, 2004, 4 (1)
[3]   Transdermal delivery of timolol by electroporation through human skin [J].
Denet, AR ;
Préat, V .
JOURNAL OF CONTROLLED RELEASE, 2003, 88 (02) :253-262
[4]  
Evans E, 2003, BIOPHYS J, V85, P2342, DOI 10.1016/S0006-3495(03)74658-X
[5]   Gene therapy: Safer and virus-free? [J].
Ferber, D .
SCIENCE, 2001, 294 (5547) :1638-1642
[6]   Stabilization of pores in lipid bilayers by anisotropic inclusions [J].
Fosnaric, M ;
Kralj-Iglic, V ;
Bohinc, K ;
Iglic, A ;
May, S .
JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (45) :12519-12526
[7]   Biodeterioration of foods and an overview of preservation in the food and dairy industries [J].
Gould, GW .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 1995, 36 (3-4) :267-277
[8]   Electroporation dynamics in biological cells subjected to ultrafast electrical pulses: A numerical simulation study [J].
Joshi, RP ;
Schoenbach, KH .
PHYSICAL REVIEW E, 2000, 62 (01) :1025-1033
[9]   Inter-pulse interval between rectangular voltage pulses affects electroporation threshold of artificial lipid bilayers [J].
Lebar, Alenka Maček ;
Troiano, Gregory C. ;
Tung, Leslie ;
Miklavčič, Damijan .
IEEE Transactions on Nanobioscience, 2002, 1 (03) :116-120
[10]  
Lebar AM, 2002, ANTICANCER RES, V22, P1731