Efficacy of reduced-size short tandem repeat PCR analysis for degraded DNA samples

被引:3
作者
Kim, Jeongyong [1 ]
Kim, Hyojeong [1 ]
Nam, Youn-Hyoung [1 ]
Lee, Ja Hyun [1 ]
Kim, Hyo Sook [1 ]
Kim, Eungsoo [2 ]
机构
[1] Natl Forens Serv, Forens DNA Div, Wonju 26460, South Korea
[2] Natl Forens Serv Seoul Inst, DNA Anal Div, Seoul 08036, South Korea
关键词
DNA analysis; Human identification; Short tandem repeats (STR); Degraded DNA; Trace DNA; Reduced-size STR (rSTR) PCR system; POWERPLEX(R) FUSION SYSTEM; DEVELOPMENTAL VALIDATION; AMPLIFICATION KIT; STR ANALYSIS; MULTIPLEX; LOCI;
D O I
10.1007/s13258-021-01066-3
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background Short tandem repeats (STR) typing is an essential analysis method for human identification in forensic field. When DNAs obtained from the field as evidences are severely degraded or in too small amounts, STR analysis often shows allele drop-out. Objective To improve STR analysis for degraded DNA or trace DNA, reduced-size STR (rSTR) polymerase chain reaction (PCR) system was devised by selecting relatively large-size STR loci. Methods The rSTR PCR system consisted of 8 loci (amelogenin, SE33, CSF1PO, D7S820, D13S317, D2S1338, TPOX, and FGA). The size of PCR product was reduced by designing new primers in the flanking region. The efficiency of this system was verified against existing kits through concordance study, sensitivity study, efficiency study, and casework sample study. Results The size of PCR product in the rSTR PCR system was reduced to be less than 322 bp. The amplicon of each locus was reduced by about 100 bp on average. Results of this rSTR PCR system were confirmed using 146 Korean samples and other commercial kits. The rSTR PCR system was capable of analyzing DNA samples with a minimum amount of DNA of 16 pg and a degradation index of 4.215. Conclusion The rSTR PCR system was more effective than other PCR kits for obtaining genetic profiles from a small amount of DNA or degraded DNA. The combination of this new system and other commercial kits is more effective than existing systems. This combination is expected to be helpful for the identification of unidentified bodies and skeletal samples.
引用
收藏
页码:749 / 758
页数:10
相关论文
共 42 条
[1]  
Ahmed, 2001, JM BUTLER Q REV BIOL, V76, P484, DOI [10.1086/420565, DOI 10.1086/420565]
[2]  
Alonso A, 2001, CROAT MED J, V42, P260
[3]   POSTMORTEM STABILITY OF DNA [J].
BAR, W ;
KRATZER, A ;
MACHLER, M ;
SCHMID, W .
FORENSIC SCIENCE INTERNATIONAL, 1988, 39 (01) :59-70
[4]   Genetic data for the locus SE33 in a Southern Italy population with AmpFlSTR NGM SElect (TM) PCR amplification kit [J].
Barbaro, A. ;
Cormaci, P. ;
La Marca, A. .
FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2011, 3 (01) :E101-E102
[5]   SE33 locus as a reliable genetic marker for forensic DNA analysis systems [J].
Bhinder, Munir Ahmad ;
Zahoor, Muhammad Yasir ;
Sadia, Haleema ;
Qasim, Muhammad ;
Perveen, Rukhsana ;
Anjum, Ghulam Murtaza ;
Iqbal, Muhammad ;
Ullah, Najeeb ;
Shehzad, Wasim ;
Tariq, Muhammad ;
Waryah, Ali Muhammad .
TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (03) :611-614
[6]  
Borsuk LA, 2017, FORENS SCI INT-GEN S, V6, pE322, DOI 10.1016/j.fsigss.2017.09.125
[7]  
Bourke MT, 1999, J FORENSIC SCI, V44, P1046
[8]   Development and validation of a novel multiplexed DNA analysis system, InnoTyper® 21 [J].
Brown, Hiromi ;
Thompson, Robyn ;
Murphy, Gina ;
Peters, Dixie ;
La Rue, Bobby ;
King, Jonathan ;
Montgomery, Anne H. ;
Carroll, Marion ;
Baus, James ;
Sinha, Sid ;
Wendt, Frank R. ;
Song, Bing ;
Chakraborty, Ranajit ;
Budowle, Bruce ;
Sinha, Sudhir K. .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2017, 29 :80-99
[9]  
Butler JM, 2003, J FORENSIC SCI, V48, P1054
[10]  
Butler JM, 2012, ADVANCED TOPICS IN FORENSIC DNA TYPING: METHODOLOGY, P1