Impact of a Safety Huddle-Based Intervention on Monitor Alarm Rates in Low-Acuity Pediatric Intensive Care Unit Patients

被引:7
作者
Dewan, Maya [1 ]
Wolfe, Heather [2 ]
Lin, Richard [2 ]
Ware, Eileen [2 ]
Weiss, Michelle [2 ]
Song, Lihai [2 ]
MacMurchy, Matthew [2 ]
Davis, Daniela [2 ]
Bonafide, Christopher P. [2 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Cincinnati, OH 45229 USA
[2] Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
RESPONSE-TIME; ASSOCIATION; FREQUENCY;
D O I
10.12788/jhm.2782
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Physiologic monitors generate high rates of alarms in the pediatric intensive care unit (PICU), yet few are actionable. OBJECTIVE: To determine the association between a huddle-based intervention focused on reducing unnecessary alarms and the change in individual patients' alarm rates in the 24 hours after huddles. DESIGN: Quasi-experimental study with concurrent and historical controls. SETTING: A 55-bed PICU. PARTICIPANTS: Three hundred low-acuity patients with more than 40 alarms during the 4 hours preceding a safety huddle in the PICU between April 1, 2015, and October 31, 2015. INTERVENTION: Structured safety huddle review and discussion of alarm causes and possible monitor parameter adjustments to reduce unnecessary alarms. MAIN MEASUREMENTS: Rate of priority alarms per 24 hours occurring for intervention patients as compared with concurrent and historical controls. Balancing measures included unexpected changes in patient acuity and code blue events. RESULTS: Clinicians adjusted alarm parameters in the 5 hours following the huddles in 42% of intervention patients compared with 24% of control patients (P = .002). The estimate of the effect of the intervention adjusted for age and sex compared with concurrent controls was a reduction of 116 priority alarms (95% confidence interval, 37-194) per 24 hours (P = .004). There were no unexpected changes in patient acuity or code blue events related to the intervention. CONCLUSION: Integrating a data-driven monitor alarm discussion into safety huddles was a safe and effective approach to reducing alarms in low-acuity, highalarm PICU patients. (C) 2017 Society of Hospital Medicine
引用
收藏
页码:652 / 657
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 2012, Sentinel Event Alert, P1
[2]   Association between exposure to nonactionable physiologic monitor alarms and response time in a children's hospital [J].
Bonafide, Christopher P. ;
Lin, Richard ;
Zander, Miriam ;
Graham, Christian Sarkis ;
Paine, Christine W. ;
Rock, Whitney ;
Rich, Andrew ;
Roberts, Kathryn E. ;
Fortino, Margaret ;
Nadkarni, Vinay M. ;
Localio, A. Russell ;
Keren, Ron .
JOURNAL OF HOSPITAL MEDICINE, 2015, 10 (06) :345-351
[3]   A Team-Based Approach to Reducing Cardiac Monitor Alarms [J].
Dandoy, Christopher E. ;
Davies, Stella M. ;
Flesch, Laura ;
Hayward, Melissa ;
Koons, Connie ;
Coleman, Kristen ;
Jacobs, Jodi ;
McKenna, Lori Ann ;
Olomajeye, Alero ;
Olson, Chad ;
Powers, Jessica ;
Shoemaker, Kimberly ;
Jodele, Sonata ;
Alessandrini, Evaline ;
Weiss, Brian .
PEDIATRICS, 2014, 134 (06) :E1686-E1694
[4]   Practice standards for electrocardiographic monitoring in hospital settings - An American Heart Association Scientific Statement from the councils on cardiovascular nursing, clinical cardiology, and cardiovascular disease in the young [J].
Drew, BJ ;
Califf, RM ;
Funk, M ;
Kaufman, ES ;
Krucoff, MW ;
Laks, MM ;
Macfarlane, PW ;
Sommargren, C ;
Swiryn, S ;
Van Hare, GF .
CIRCULATION, 2004, 110 (17) :2721-2746
[5]   Huddling for high reliability and situation awareness [J].
Goldenhar, Linda M. ;
Brady, Patrick W. ;
Sutcliffe, Kathleen M. ;
Muething, Stephen E. .
BMJ QUALITY & SAFETY, 2013, 22 (11) :899-906
[6]  
Korniewicz DM, 2008, AM J CRIT CARE, V17, P36
[7]   CRYING WOLF - FALSE ALARMS IN A PEDIATRIC INTENSIVE-CARE UNIT [J].
LAWLESS, ST .
CRITICAL CARE MEDICINE, 1994, 22 (06) :981-985
[8]   Systematic Review of Physiologic Monitor Alarm Characteristics and Pragmatic Interventions to Reduce Alarm Frequency [J].
Paine, Christine Weirich ;
Goel, Veena V. ;
Ely, Elizabeth ;
Stave, Christopher D. ;
Stemler, Shannon ;
Zander, Miriam ;
Bonafide, Christopher P. .
JOURNAL OF HOSPITAL MEDICINE, 2016, 11 (02) :136-144
[9]   What Are We Missing? Arrhythmia Detection in the Pediatric Intensive Care Unit [J].
Rosman, Eliyahu C. ;
Blaufox, Andrew D. ;
Menco, Amanda ;
Trope, Randi ;
Seiden, Howard S. .
JOURNAL OF PEDIATRICS, 2013, 163 (02) :511-514
[10]   The frequency of physiologic monitor alarms in a children's hospital [J].
Schondelmeyer, Amanda C. ;
Bonafide, Christopher P. ;
Goel, Veena V. ;
Blake, Nancy ;
Cvach, Maria ;
Sucharew, Heidi ;
Simmons, Jeffrey M. ;
Brady, Patrick W. .
JOURNAL OF HOSPITAL MEDICINE, 2016, 11 (11) :796-798