A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury A retrospective cohort study

被引:8
作者
Kurtoglu, Alper [1 ]
Kochai, Alauddin [1 ]
Inanmaz, Mustafa Erkan [1 ]
Sukur, Erhan [1 ]
Keskin, Dogan [1 ]
Turker, Mehmet [1 ]
Uysal, Mustafa [1 ]
Sen, Zafer [2 ]
Daldal, Ismail [3 ]
机构
[1] Sakarya Univ, Res & Training Hosp, Adaparari, Sakarya, Turkey
[2] Univ Hlth Sci, Konya City Hosp Orthoped & Traumatol, Ankara, Turkey
[3] Lokman Hekim Akay Hosp Dept Orthopaed & Traumatol, Ankara, Turkey
关键词
ankle fracture; American Orthopaedic Foot and Ankle Society; screw fixation; suture endobutton; syndesmosis injury; DISTAL TIBIOFIBULAR SYNDESMOSIS; FRACTURES; REMOVAL; RISK;
D O I
10.1097/MD.0000000000025328
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Different methods have been used throughout the years for syndesmotic injury but there is no consensus on the ideal treatment. Some methods are expensive and some have more complications. The aim of this study is to compare single suture endobutton with double suture endobutton and screw fixation for syndesmotic injury. Sixty nine patients with syndesmotic injury with fibular fractures whom were treated with a single interosseous suture endobutton system (ZipTight(TM), Zimmer Biomet), a double interosseous suture endobutton system (ZipTight(TM), Zimmer Biomet) and 1 syndesmotic screw (TST, Istanbul, Turkey) were included in this study. Functional and radiological results from patient records between 2015 and 2018 were retrospectively evaluated. Twenty patients were treated with the double interosseous suture endobutton, 23 were treated with the single interosseous suture endobutton, and 26 were treated with traditional AO screw fixation. Three patients from the screw fixation group (11.5%) required revision surgery (P < .05). All the radiologic and clinical outcomes were statistical similar in all 3 groups. Our findings showed that the interosseous suture endobutton system is at least as safe as the screw fixation technique for treatment of syndesmosis joint injuries and can be used as an alternative to the screw method. The interosseous suture endobutton system eliminates the need for a second surgery to remove the hardware, which minimizes the probability of re-diastasis. Since our results showed no statistical difference between single and double interosseous suture endobutton systems, the less costly single endobutton system may be the better alternative.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Association of Periprosthetic Fibula Fracture With Knotless Suture Button (TightRope) Fixation for Ankle Syndesmosis in Elite Athletes
    Hong, Choon Chiet
    Harrison, William D.
    Clough, Tim
    Calder, James
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (11)
  • [42] Comparison of tendon suture fixation and cortical screw fixation for treatment of distal tibiofibular syndesmosis injury A case-control study
    Song, Liuhong
    Liao, Zhifu
    Kuang, Zhongqiang
    Qu, Shiyan
    Zhang, Wei
    Yuan, Yang
    Fang, Teng
    MEDICINE, 2020, 99 (34) : E21573
  • [43] Complications and Return to Sport Between Screw Fixation and Suture Button Fixation for Arthroscopic Latarjet in a 2-year Follow-up: A Retrospective Cohort Study
    Magnuson, Justin A.
    Mozes, Gabriel
    Parnes, Nata
    Scanaliato, John P.
    Oh, Luke S.
    Ryan Tyler, John
    Yeramosu, Teja
    Mozes, Adam D.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2025, 13 (03)
  • [44] Randomized Trial Comparing Suture Button with Single Syndesmotic Screw for Syndesmosis Injury
    Andersen, Mette Renate
    Frihagen, Frede
    Hellund, Johan Castberg
    Madsen, Jan Erik
    Figved, Wender
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (01) : 2 - 12
  • [45] Deep Infections After Syndesmotic Fixation With a Suture Button Device
    Fantry, Amanda J.
    O'Donnell, Seth W.
    Born, Chris T.
    Hayda, Roman A.
    ORTHOPEDICS, 2017, 40 (03) : E541 - E545
  • [46] Syndesmotic Suture Button Fixation Results in Higher Tegner Activity Scale Scores When Compared to Screw Fixation: A Multicenter Investigation
    Obey, Mitchel R.
    Schafer, Kevin
    Matheny, Lauren M.
    Mcandrew, Christopher M.
    Gardner, Michael J.
    Ricci, William M.
    Clanton, Thomas O.
    Backus, Jonathon D.
    FOOT & ANKLE SPECIALIST, 2024, 17 (03) : 270 - 276
  • [47] The Effect of Varying Tension of a Suture Button Construct in Fixation of the Tibiofibular Syndesmosis-Evaluation Using Stress Computed Tomography
    Morellato, John
    Louati, Hakim
    Bodrogi, Andrew
    Stewart, Andrew
    Papp, Steven
    Liew, Allan
    Gofton, Wade
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (02) : 103 - 110
  • [48] Biomechanical Analysis of a Novel Syndesmotic Plate Compared With Traditional Screw and Suture Button Fixation
    Weng, Qihao
    Lin, Chuanlu
    Liu, Yang
    Dai, Gaole
    Lutchooman, Vinesh
    Hong, Jianjun
    JOURNAL OF FOOT & ANKLE SURGERY, 2020, 59 (03) : 522 - 528
  • [49] Irrigation and Debridement of an Open Ankle Fracture With Open Reduction and Internal Fixation and Syndesmotic Fixation Using a Suture Button Device
    Davis, Max E.
    Blum, Laura
    Talusan, Paul G.
    Hake, Mark E.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 : S40 - S41
  • [50] Suture button fixation method used in the treatment of syndesmosis injury: A biomechanical analysis of the effect of the placement of the button on the distal tibiofibular joint in the mid-stance phase with finite elements method
    Guvercin, Yilmaz
    Abdioglu, Ahmet Atilla
    Dizdar, Ayberk
    Yaylaci, Ecren Uzun
    Yaylaci, Murat
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (07): : 2437 - 2445