A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury A retrospective cohort study

被引:8
作者
Kurtoglu, Alper [1 ]
Kochai, Alauddin [1 ]
Inanmaz, Mustafa Erkan [1 ]
Sukur, Erhan [1 ]
Keskin, Dogan [1 ]
Turker, Mehmet [1 ]
Uysal, Mustafa [1 ]
Sen, Zafer [2 ]
Daldal, Ismail [3 ]
机构
[1] Sakarya Univ, Res & Training Hosp, Adaparari, Sakarya, Turkey
[2] Univ Hlth Sci, Konya City Hosp Orthoped & Traumatol, Ankara, Turkey
[3] Lokman Hekim Akay Hosp Dept Orthopaed & Traumatol, Ankara, Turkey
关键词
ankle fracture; American Orthopaedic Foot and Ankle Society; screw fixation; suture endobutton; syndesmosis injury; DISTAL TIBIOFIBULAR SYNDESMOSIS; FRACTURES; REMOVAL; RISK;
D O I
10.1097/MD.0000000000025328
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Different methods have been used throughout the years for syndesmotic injury but there is no consensus on the ideal treatment. Some methods are expensive and some have more complications. The aim of this study is to compare single suture endobutton with double suture endobutton and screw fixation for syndesmotic injury. Sixty nine patients with syndesmotic injury with fibular fractures whom were treated with a single interosseous suture endobutton system (ZipTight(TM), Zimmer Biomet), a double interosseous suture endobutton system (ZipTight(TM), Zimmer Biomet) and 1 syndesmotic screw (TST, Istanbul, Turkey) were included in this study. Functional and radiological results from patient records between 2015 and 2018 were retrospectively evaluated. Twenty patients were treated with the double interosseous suture endobutton, 23 were treated with the single interosseous suture endobutton, and 26 were treated with traditional AO screw fixation. Three patients from the screw fixation group (11.5%) required revision surgery (P < .05). All the radiologic and clinical outcomes were statistical similar in all 3 groups. Our findings showed that the interosseous suture endobutton system is at least as safe as the screw fixation technique for treatment of syndesmosis joint injuries and can be used as an alternative to the screw method. The interosseous suture endobutton system eliminates the need for a second surgery to remove the hardware, which minimizes the probability of re-diastasis. Since our results showed no statistical difference between single and double interosseous suture endobutton systems, the less costly single endobutton system may be the better alternative.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A Comparison of Screw Fixation and Suture-Button Fixation in a Syndesmosis Injury in an Ankle Fracture
    Kim, Jung-Han
    Gwak, Heui-Chul
    Lee, Chang-Rack
    Choo, Hye-Jeung
    Kim, Jeon-Gyo
    Kim, Dae-Yoo
    JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (05) : 985 - 990
  • [2] Injury mechanism affects the stability of suture-button syndesmosis fixation
    Chen, Kuan-Hao
    Chen, Chih-Hwa
    Huang, Yu-min
    Lee, Hsieh-Hsing
    Tsuang, Yang-Hwei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [3] Injury mechanism affects the stability of suture-button syndesmosis fixation
    Kuan-Hao Chen
    Chih-Hwa Chen
    Yu-min Huang
    Hsieh-Hsing Lee
    Yang-Hwei Tsuang
    Journal of Orthopaedic Surgery and Research, 15
  • [4] Suture-Button Versus Screw Fixation in a Syndesmosis Rupture Model: A Biomechanical Comparison
    Soin, Sandeep P.
    Knight, Trevor A.
    Dinah, A. Feroz
    Mears, Simon C.
    Swierstra, Bart A.
    Belkoff, Stephen M.
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (04) : 346 - 352
  • [5] Comparison of suture-button and screw fixation in the treatment of ankle syndesmotic injuries Cohort study protocol
    Liu, Xiaoning
    Jin, Guang
    Piao, Chengdong
    Zhong, Zhuan
    Chang, Fei
    Huang, Bingzhe
    MEDICINE, 2020, 99 (32) : E21679
  • [6] Comparison of Different Fixation Methods of the Suture-Button Implant for Tibiofibular Syndesmosis Injuries
    Teramoto, Atsushi
    Suzuki, Daisuke
    Kamiya, Tomoaki
    Chikenji, Takako
    Watanabe, Kota
    Yamashita, Toshihiko
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10) : 2226 - 2232
  • [7] The Clinical Efficacy of Suture-Button Fixation and Trans-Syndesmotic Screw Fixation in the Treatment of Ankle Fracture Combined With Distal Tibiofibular Syndesmosis Injury: A Retrospective Study
    Xu, Yibo
    Kang, Ran
    Li, Ming
    Li, Zhong
    Ma, Teng
    Ren, Cheng
    Wang, Qian
    Lu, Yao
    Zhang, Kun
    JOURNAL OF FOOT & ANKLE SURGERY, 2022, 61 (01) : 143 - 148
  • [8] The Impact of Suture Button Removal in Syndesmosis Fixation
    Kim, Jaeyoung
    Kwon, Minsoo
    Day, Jonathan
    Seilern und Aspang, Jesse
    Shim, Jaehoon
    Cho, Jaeho
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (16)
  • [9] Strength of suture-button fixation versus ligament reconstruction in syndesmotic injury: a biomechanical study
    Li, Hong-Yun
    Zhou, Ru-Shou
    Wu, Zi-Ying
    Zhao, Yutong
    Chen, Shi-Yi
    Hua, Ying-Hui
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) : 705 - 711
  • [10] Suture-Button Versus Syndesmotic Screw Fixation of Ankle Fractures: A Comparative Retrospective Review Over One Year
    Yawar, Bakhat
    Hanratty, Brian
    Asim, Ayeisha
    Niazi, Aamir K.
    Khan, Abdul M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)