Feasibility of ultra-low contrast 64-slice computed tomography angiography before transcatheter aortic valve implantation: a real-world experience

被引:29
作者
Spagnolo, Pietro [1 ]
Giglio, Manuela [1 ]
Di Marco, Daniela [2 ]
Latib, Azeem [3 ,4 ]
Besana, Francesca [1 ]
Chieffo, Alaide [3 ,4 ]
Montorfano, Matteo [3 ,4 ]
Sironi, Sandro [2 ]
Alfieri, Ottavio [5 ]
Colombo, Antonio [3 ,4 ]
机构
[1] Ist Sci San Raffaele, Cardiovasc Dis Prevent Ctr CPC, Via Olgettina 60, I-20132 Milan, Italy
[2] Univ Milano Bicocca, Sch Med, Milan, Italy
[3] Ist Sci San Raffaele, Intervent Cardiol Unit, I-20132 Milan, Italy
[4] Ist Sci San Raffaele, Cardiothorac Dept, I-20132 Milan, Italy
[5] Ist Sci San Raffaele, Cardiac Surg Dept, I-20132 Milan, Italy
关键词
CT angiography; contrast injection; transcatheter aortic valve implantation; contrast-induced acute kidney injury; ACUTE KIDNEY INJURY; DUAL-SOURCE CT; ROOT; PREDICTORS;
D O I
10.1093/ehjci/jev175
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To investigate the feasibility, image quality, and clinical implications of an ultra-low-dose contrast injection computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI). Methods and results Images obtained with 64-slice CT were retrospectively evaluated in 162 TAVI candidates with a body mass index (BMI) of <= 29 kg/m(2). A multiphasic, low iodine dose and BMI-adapted CM protocol was administered in all patients (BMI <22 kg/m(2): 40 mL; BMI 22-29 kg/m(2): 55 mL). All images were evaluated for image quality, vessel attenuation, and estimated radiation dose. The anatomy, diameters, perimeter, and area of the aortic annulus were assessed. Anatomy and diameters of peripheral vessels were also evaluated. Image quality of the aortic root and ilio-femoral vessels was diagnostic in all patients. Vascular attenuation was >200 HU at any vessel level. The mean diameters of the aortic annulus were 22 +/- 3 mm (range: 16-28 mm) x 26 +/- 3 mm (range: 20-33 mm); the mean perimeter was 77.0 +/- 7.1 mm. After CTA, a total of 137 patients (84.6%) underwent TAVI. Mean estimated radiation dose was 20.2 +/- 4.6 mSv. Conclusion With our protocol, we achieved images of the aortic annulus and aorto-iliac anatomy of sufficient quality to allow patient selection and procedural planning for TAVI, with a substantial reduction of the amount of injected CM.
引用
收藏
页码:24 / 33
页数:10
相关论文
共 30 条
  • [1] Ultra-Low Contrast Computed Tomographic Angiography (CTA) With 20-mL Total Dose for Transcatheter Aortic Valve Implantation (TAVI) Planning
    Azzalini, Lorenzo
    Abbara, Suhny
    Ghoshhajra, Brian B.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 105 - 109
  • [2] Acute kidney injury following transcatheter aortic valve implantation: predictive factors, prognostic value, and comparison with surgical aortic value replacement
    Bagur, Rodrigo
    Webb, John G.
    Nietlispach, Fabian
    Dumont, Eric
    De Larochelliere, Robert
    Doyle, Daniel
    Masson, Jean-Bernard
    Gutierrez, Marcos J.
    Clavel, Marie-Annick
    Bertrand, Olivier F.
    Pibarot, Philippe
    Rodes-Cabau, Josep
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (07) : 865 - 874
  • [3] Incidence and predictors of acute kidney injury after transcatheter aortic valve replacement
    Barbash, Israel M.
    Ben-Dor, Itsik
    Dvir, Danny
    Maluenda, Gabriel
    Xue, Zhenyi
    Torguson, Rebecca
    Satler, Lowell F.
    Pichard, Augusto D.
    Waksman, Ron
    [J]. AMERICAN HEART JOURNAL, 2012, 163 (06) : 1031 - 1036
  • [4] Use of iso-osmolar nonionic dimeric contrast media in multidetector row computed tomography angiography for patients with renal impairment
    Becker, CR
    Reiser, MF
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (10) : 672 - 675
  • [5] Combined Assessment of Aortic Root Anatomy and Aortoiliac Vasculature With Dual-Source CT as a Screening Tool in Patients Evaluated for Transcatheter Aortic Valve Implantation
    Blanke, Philipp
    Euringer, Wulf
    Baumann, Tobias
    Reinoehl, Jochen
    Schlensak, Christian
    Langer, Mathias
    Pache, Gregor
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) : 872 - 881
  • [6] Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team
    Bleiziffer, Sabine
    Ruge, Hendrik
    Mazzitelli, Domenico
    Schreiber, Christian
    Hutter, Andrea
    Laborde, Jean-Claude
    Bauernschmitt, Robert
    Lange, Ruediger
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (04) : 615 - 621
  • [7] Chertow GM, 1997, CIRCULATION, V95, P878
  • [8] Mortality associated with nephropathy after radiographic contrast exposure
    From, Aaron M.
    Bartholmai, Brian J.
    Williams, Amy W.
    Cha, Stephen S.
    Mcdonald, Furman S.
    [J]. MAYO CLINIC PROCEEDINGS, 2008, 83 (10) : 1095 - 1100
  • [9] Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1093/ejcts/ezs533, 10.1016/j.jacc.2012.09.001]
  • [10] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429