Real-time condition monitoring of the electrolytic capacitors for power electronics applications

被引:58
作者
Imam, Afroz M. [1 ]
Divan, Deepak M. [1 ]
Harley, Ronald G. [1 ]
Habetler, Thomas G. [1 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
来源
APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2 | 2007年
关键词
D O I
10.1109/APEX.2007.357646
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The objective of this paper is to propose a new low cost method to detect the changes in equivalent series resistor (ESR) and the capacitance value of an electrolytic capacitor in order to realize the real-time condition monitoring of an electrolytic capacitor. Experimental and simulation results are discussed to illustrate the proposed condition monitoring technique. In addition, it is shown that the proposed method can be used for a non-stationary system where waveforms are continuously varying in amplitude, frequency, and phase. The proposed on-line failure prediction method has the merits of low cost and circuit simplicity.
引用
收藏
页码:1057 / +
页数:2
相关论文
共 7 条
  • [1] Gasperi ML, 1997, IEEE IND APPLIC SOC, P1042, DOI 10.1109/IAS.1997.628989
  • [2] Gasperi ML, 1996, IEEE IND APPLIC SOC, P1347, DOI 10.1109/IAS.1996.559241
  • [3] HARADA K, 1993, IEEE T POWER ELECTR, V4, P355
  • [4] Failure prediction of electrolytic capacitors during operation of a switchmode power supply
    Lahyani, A
    Venet, P
    Grellet, G
    Viverge, PJ
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (06) : 1199 - 1207
  • [5] Sankaran VA, 1997, IEEE IND APPLIC SOC, P1058, DOI 10.1109/IAS.1997.628992
  • [6] VENET P, 1993, INTELEC 93 - 15TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, VOL 2, P229
  • [7] Realization of a smart electrolytic capacitor circuit
    Venet, P
    Perisse, F
    El-Husseini, MH
    Rojat, G
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (01) : 16 - 20