Validity of different tools to assess sleep bruxism: a meta-analysis

被引:63
作者
Casett, E. [1 ]
Reus, J. C. [1 ]
Stuginski-Barbosa, J. [2 ]
Porporatti, A. L. [3 ]
Carra, M. C. [4 ]
Peres, M. A. [5 ]
de Luca Canto, G. [3 ,6 ]
Manfredini, D. [7 ]
机构
[1] Univ Fed Santa Catarina, Sch Dent, Florianopolis, SC, Brazil
[2] Bauru Orofacial Pain Grp, Bauru, Brazil
[3] Univ Fed Santa Catarina, Brazilian Ctr Evidence Based Res, Dept Dent, Florianopolis, SC, Brazil
[4] Paris Diderot Univ, Hop Rothschild, AP HP, Serv Odontol, Paris, France
[5] Univ Adelaide, Australian Res Ctr Populat Oral Hlth, Adelaide Dent Sch, Adelaide, SA, Australia
[6] Univ Alberta, Sch Dent, Fac Med & Dent, Edmonton, AB, Canada
[7] Univ Padua, Sch Dent, Padua, Italy
关键词
sleep bruxism; diagnosis; polysomnography; systematic review; meta-analysis; evidence-based dentistry; DIAGNOSTIC-CRITERIA; PREDICTIVE VALUES; TOOTH WEAR; POLYSOMNOGRAPHY; VALIDATION; BITESTRIP; DISORDER;
D O I
10.1111/joor.12520
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This systematic review and meta-analysis (MA) aimed to evaluate the diagnostic validity of questionnaires, clinical assessment and portable diagnostic devices compared to the reference standard method polysomnography (PSG) in assessing sleep bruxism (SB). Two reviewers searched electronic databases for diagnostic test accuracy studies that compared questionnaires, clinical assessment or portable diagnostic devices for SB, with the reference standard method PSG, comprising previous studies from all languages and with no restrictions regarding age, gender or time of publication. Of the 351 articles, eight met the inclusion criteria for qualitative, and seven for quantitative analysis. The methodology of selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). The studies were divided and analysed over three groups: three studies evaluating questionnaires, two regarding the clinical assessment of tooth wear and three covering portable diagnostic devices. The MA indicated that portable diagnostic devices showed the best validity of all evaluated methods, especially as far as a four-channel EMG/ECG recording is concerned. Questionnaires and the clinical assessment can be used as screening methods to identify non-SB individuals, although it is not that good in identifying subjects with SB. The quality of evidence identified through GRADEpro, was from very low-to-moderate, due to statistical heterogeneity between studies.
引用
收藏
页码:722 / 734
页数:13
相关论文
共 34 条
  • [1] Abe S, 2009, INT J PROSTHODONT, V22, P342
  • [2] [Anonymous], 2010, COCHRANE HDB SYSTEMA
  • [3] [Anonymous], DIAGNOSTIC VALIDITY
  • [4] [Anonymous], 2013, COCHRANE HDB SYSTEMA
  • [5] Baba K, 2004, INT J PROSTHODONT, V17, P39
  • [6] Bader G, 2000, INT J PROSTHODONT, V13, P327
  • [7] Diagnostic accuracy of sleep bruxism scoring in absence of audio-video recording: a pilot study
    Carra, Maria Clotilde
    Nelly Huynh
    Lavigne, Gilles J.
    [J]. SLEEP AND BREATHING, 2015, 19 (01) : 183 - 190
  • [8] Carra Maria Clotilde, 2012, Dent Clin North Am, V56, P387, DOI 10.1016/j.cden.2012.01.003
  • [9] Detection of sleep bruxism: comparison between an electromyographic and electrocardiographic portable holter and polysomnography
    Castroflorio, T.
    Deregibus, A.
    Bargellini, A.
    Debernardi, C.
    Manfredini, D.
    [J]. JOURNAL OF ORAL REHABILITATION, 2014, 41 (03) : 163 - 169
  • [10] TIME-FREQUENCY ANALYSIS OF RHYTHMIC MASTICATORY MUSCLE ACTIVITY
    Farella, Mauro
    Palla, Sandro
    Gallo, Luigi Maria
    [J]. MUSCLE & NERVE, 2009, 39 (06) : 828 - 836