INVESTIGATION OF SUSTAINABLE COOLING STRATEGY FOR DATA CENTER

被引:0
作者
Lu, Tao [1 ]
Lu, Xiaoshu [1 ]
Viljanen, Martti [1 ]
机构
[1] Aalto Univ, Sch Engn, Dept Civil & Struct Engn, POB 12100, FIN-02015 Espoo, Finland
来源
SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS | 2013年
关键词
sustainable; data center; energy performance; heat recovery; MANAGEMENT;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is noticed that energy consumption in data centers has increased dramatically in recent years due to the increased demands for data center computing. One of the most efficient ways to improve a data center's sustainability is by reducing power and cooling usage. The paper aims to investigate the possibilities of improvement of more sustainable energy saving strategies for data centers. We particularly evaluate air management and energy performance of cooling system and explore the potential of energy saving and reuse through a case study of a data center in Finland. We provide assessment of performance metrics for the cooling system and power consumption of the data center. Based on the analysis results, a simulated heat recovery system is presented demonstrating that the data center could potentially provide yearly space and hot water heating for 30,916 m(2) non-domestic building.
引用
收藏
页码:693 / 696
页数:4
相关论文
共 50 条
[31]   Adaptive Predictive Control of a data center cooling unit [J].
Martinez-Garcia, Fernando ;
Badawy, Ghada ;
Kheradmandi, Masoud ;
Down, Douglas G. .
CONTROL ENGINEERING PRACTICE, 2021, 107
[32]   Influence of cooling architecture on data center power consumption [J].
Moazamigoodarzi, Hosein ;
Tsai, Peiying Jennifer ;
Pal, Souvik ;
Ghosh, Suvojit ;
Puri, Ishwar K. .
ENERGY, 2019, 183 :525-535
[33]   OPTIMIZING DATA CENTER COOLING INFRASTRUCTURES USING EXERGOTHERMOVOLUMES [J].
Shah, Amip ;
Bash, Cullen ;
Patel, Chandrakant .
2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
[34]   Minimizing Data Center Cooling and Server Power Costs [J].
Pakbaznia, Ehsan ;
Pedram, Massoud .
ISLPED 09, 2009, :145-150
[35]   Optimization of Energy Efficiency of Data Center Cooling Systems [J].
Chen, Lei ;
Li, Xiaoli ;
Wang, Kang ;
Yu, Xiaowei .
PROCEEDINGS OF THE 36TH CHINESE CONTROL AND DECISION CONFERENCE, CCDC 2024, 2024, :76-81
[36]   Immersion cooling technology development status of data center [J].
Zhou, Kun ;
Yu, Xiaolin ;
Xie, Baogang ;
Xie, Hongxi ;
Fu, Wei .
SCIENCE AND TECHNOLOGY FOR ENERGY TRANSITION, 2024, 79
[37]   Experimental investigation on application potential of phase change assisted direct ventilation cooling system for Gui'an data center [J].
Yang, Lingyan ;
Wu, Hongwei ;
Zhang, Zujing ;
Mao, Ruiyong ;
Zhou, Jiri ;
Liang, Xing .
APPLIED THERMAL ENGINEERING, 2024, 254
[38]   Experimental and numerical investigation on thermal performance of data center via fan-wall free cooling technology [J].
Lan, Jiang ;
Zhang, Zujing ;
Liang, Xing ;
Wu, Hongwei ;
Wang, Gang ;
Mao, Ruiyong .
APPLIED THERMAL ENGINEERING, 2023, 228
[39]   An efficient assessment method for the thermal environment of a row-based cooling data center [J].
Wang, Ligang ;
Wang, Yating ;
Bai, Xuelian ;
Wu, Tong ;
Ma, Yuhong ;
Jin, Yewei ;
Jiang, Hang .
APPLIED THERMAL ENGINEERING, 2025, 269
[40]   Experimental research on the influence of a novel passive cooling system on the data center temperature distribution [J].
Wang, Ye ;
Zheng, Wenke ;
Shi, Guozheng ;
Jiang, Yiqiang ;
Sun, Cheng ;
Guo, Jiwei .
ENERGY AND BUILDINGS, 2023, 292