Simple assay of plasma sevoflurane and its metabolite hexafluoroisopropanol by headspace GC-MS

被引:12
作者
Bourdeaux, Daniel [1 ,2 ]
Sautou-Miranda, Valerie [1 ,2 ]
Montagner, Agnes [1 ]
Perbet, Sebastien [3 ]
Constantin, Jean Michel [3 ]
Bazin, Jean-Etienne [3 ]
Chopineau, Jean [1 ,2 ]
机构
[1] CHU Clermont Ferrand, Dept Pharm, Hop Montpied G, F-63003 Clermont Ferrand, France
[2] Univ Clermont 1, Fac Pharm, Lab Clin Pharm & Biotechn, F-63001 Clermont Ferrand, France
[3] CHU Clermont Ferrand, Surg Intens Care Unit, Dept Anesthesiol & Crit Care Med, Hotel Dieu, F-63000 Clermont Ferrand, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 01期
关键词
Sevoflurane; HFIP; Headspace gas chromatography; Mass spectroscopy; Pharmacokinetic study; Anesthetic conserving device; CHROMATOGRAPHY-MASS SPECTROMETRY; ANESTHETIC CONSERVING DEVICE; CARBON-DISULFIDE; CIRCLE SYSTEM; PHARMACOKINETICS; ISOFLURANE; DISPOSITION; EXPOSURE; BLOOD;
D O I
10.1016/j.jchromb.2009.11.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The anesthetic sevoflurane can now be delivered over periods of up to 48 h using a newly developed medical system, the AnaConDa (anesthetic conserving device). Lack of pharmacokinetic data on sevoflurane and its main metabolite (hexafluoroisopropanol, HFIP) in this indication prompted us to develop a headspace GC-MS method to quantify the two substances. The only previously published method for assaying the two substances Could not be adapted to our study since it uses expensive and rarely employed system components together with toxic carbon disulfide as a dilution solvent. The method developed is straightforward and uses the relatively non-toxic solvent undecane as dilution solvent and chloroform as internal standard. The method is linear for a concentration range of 1-150 mu g/ml, and presents high accuracy and precision. LOD and LOQ are 0.2 and 1 mu g/ml, with a short analysis time (7.6 min for a single analysis). The method was applied to determine the plasma levels of sevoflurane and HFIP in six patients under 48-h anesthetic sedation delivered via the AnaConDa system. Average sevoflurane and HFIP concentrations plateaued at 75 and 4 mu g/ml. respectively. Sevoflurane quickly tailed off after inhalation was stopped, and HFIP levels remained low. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 19 条
[1]   Simultaneous determination of unmodified sevoflurane and of its metabolite hexafluoroisopropanol in urine by headspace sorptive extraction-thermal desorption-capillary gas chromatography-mass spectrometry [J].
Accorsi, A ;
Morrone, B ;
Benzo, M ;
Gandini, C ;
Raffi, GB ;
Violante, FS .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :131-134
[2]   Biomonitoring of exposure to nitrous oxide, sevoflurane, isoflurane and halothane by automated GC/MS headspace urinalysis [J].
Accorsi, A ;
Barbieri, A ;
Raffi, GB ;
Violante, FS .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2001, 74 (08) :541-548
[3]   ANALYSIS OF SEVOFLURANE DEGRADATION PRODUCTS IN VAPOR-PHASE SAMPLES [J].
CUNNINGHAM, DD ;
WEBSTER, J ;
NELSON, D ;
WILLIAMSON, B .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 668 (01) :41-52
[4]   The sevoflurane saving capacity of a new anaesthetic agent conserving device compared with a low flow circle system [J].
Enlund, M ;
Lambert, H ;
Wiklund, L .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (05) :506-511
[5]  
Huang Chin-Chang, 2004, Acta Neurol Taiwan, V13, P3
[6]   CLINICAL SEVOFLURANE METABOLISM AND DISPOSITION .1. SEVOFLURANE AND METABOLITE PHARMACOKINETICS [J].
KHARASCH, ED ;
KAROL, MD ;
LANNI, C ;
SAWCHUK, R .
ANESTHESIOLOGY, 1995, 82 (06) :1369-1378
[7]   CLINICAL SEVOFLURANE METABOLISM AND DISPOSITION .2. THE ROLE OF CYTOCHROME-P450 2E1 IN FLUORIDE AND HEXAFLUOROISOPROPANOL FORMATION [J].
KHARASCH, ED ;
ARMSTRONG, AS ;
GUNN, K ;
ARTRU, A ;
COX, K ;
KAROL, MD .
ANESTHESIOLOGY, 1995, 82 (06) :1379-1388
[8]   Cardiac protection by volatile anaesthetics: A review [J].
Landoni, Giovanni ;
Fochi, Oliviero ;
Torri, Giorgio .
CURRENT VASCULAR PHARMACOLOGY, 2008, 6 (02) :108-111
[9]   Pharmacokinetics of sevoflurane uptake into the brain and body [J].
Lu, CC ;
Tsai, CS ;
Ho, ST ;
Chen, WY ;
Wong, CS ;
Wang, JJ ;
Hu, OYP ;
Lin, CY .
ANAESTHESIA, 2003, 58 (10) :951-956
[10]   A SIMPLIFIED GAS-CHROMATOGRAPHIC METHOD FOR QUANTIFYING THE SEVOFLURANE METABOLITE HEXAFLUOROISOPROPANOL [J].
MORGAN, SE ;
FRINK, EJ ;
GANDOLFI, AJ .
ANESTHESIOLOGY, 1994, 80 (01) :201-205