Comparison between conventional and compressed sensing cine cardiovascular magnetic resonance for feature tracking global circumferential strain assessment

被引:18
作者
Kido, Tomoyuki [1 ]
Hirai, Kuniaki [2 ]
Ogawa, Ryo [1 ]
Tanabe, Yuki [1 ]
Nakamura, Masashi [1 ]
Kawaguchi, Naoto [1 ]
Kurata, Akira [1 ]
Watanabe, Kouki [3 ]
Schmidt, Michaela [4 ]
Forman, Christoph [4 ]
Mochizuki, Teruhito [5 ,6 ]
Kido, Teruhito [1 ]
机构
[1] Ehime Univ, Dept Radiol, Grad Sch Med, Toon, Ehime 7910295, Japan
[2] Uwajima City Hosp, Dept Radiol, Uwajima, Japan
[3] Saiseikai Matsuyama Hosp, Dept Cardiol, Matsuyama, Ehime, Japan
[4] Siemens Healthcare GmbH, Erlangen, Germany
[5] Yoshino Hosp, Dept Radiol, Imabari, Japan
[6] IM Sechenov First Moscow State Med Univ, Dept Radiol, Moscow, Russia
关键词
Compressed sensing; Cardiovascular magnetic resonance; Feature tracking; Myocardial strain;
D O I
10.1186/s12968-021-00708-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundFeature tracking (FT) has become an established tool for cardiovascular magnetic resonance (CMR)-based strain analysis. Recently, the compressed sensing (CS) technique has been applied to cine CMR, which has drastically reduced its acquisition time. However, the effects of CS imaging on FT strain analysis need to be carefully studied. This study aimed to investigate the use of CS cine CMR for FT strain analysis compared to conventional cine CMR.MethodsSixty-five patients with different left ventricular (LV) pathologies underwent both retrospective conventional cine CMR and prospective CS cine CMR using a prototype sequence with the comparable temporal and spatial resolution at 3 T. Eight short-axis cine images covering the entire LV were obtained and used for LV volume assessment and FT strain analysis. Prospective CS cine CMR data over 1.5 heartbeats were acquired to capture the complete end-diastolic data between the first and second heartbeats. LV volume assessment and FT strain analysis were performed using a dedicated software (ci(42); Circle Cardiovasacular Imaging, Calgary, Canada), and the global circumferential strain (GCS) and GCS rate were calculated from both cine CMR sequences.ResultsThere were no significant differences in the GCS (-17.1% [-11.7, -19.5] vs. -16.1% [-11.9, -19.3; p=0.508) and GCS rate (-0.8 [-0.6, -1.0] vs. -0.8 [-0.7, -1.0]; p=0.587) obtained using conventional and CS cine CMR. The GCS obtained using both methods showed excellent agreement (y=0.99x-0.24; r=0.95; p<0.001). The Bland-Altman analysis revealed that the mean difference in the GCS between the conventional and CS cine CMR was 0.1% with limits of agreement between -2.8% and 3.0%. No significant differences were found in all LV volume assessment between both types of cine CMR.ConclusionCS cine CMR could be used for GCS assessment by CMR-FT as well as conventional cine CMR. This finding further enhances the clinical utility of high-speed CS cine CMR imaging.
引用
收藏
页数:9
相关论文
共 35 条
[31]   Prediction of All-Cause Mortality From Global Longitudinal Speckle Strain Comparison With Ejection Fraction and Wall Motion Scoring [J].
Stanton, Tony ;
Leano, Rodel ;
Marwick, Thomas H. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (05) :356-364
[32]   Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: A comparison with cine magnetic resonance imaging [J].
Vaduganathan, P ;
He, ZX ;
Vick, GW ;
Mahmarian, JJ ;
Verani, MS .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (01) :3-10
[33]   Compressed Sensing Single-Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass [J].
Vincenti, Gabriella ;
Monney, Pierre ;
Chaptinel, Jerome ;
Rutz, Tobias ;
Coppo, Simone ;
Zenge, Michael O. ;
Schmidt, Michaela ;
Nadar, Mariappan S. ;
Piccini, Davide ;
Chevre, Pascal ;
Stuber, Matthias ;
Schwitter, Juerg .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (09) :882-892
[34]   Influence of contrast agent and spatial resolution on myocardial strain results using feature tracking MRI [J].
von Knobelsdorff-Brenkenhoff, Florian ;
Schunke, Tobias ;
Reiter, Stephanie ;
Scheck, Roland ;
Hoefling, Berthold ;
Pilz, Guenter .
EUROPEAN RADIOLOGY, 2020, 30 (11) :6099-6108
[35]   Imaging Three-Dimensional Myocardial Mechanics Using Navigator-Gated Volumetric Spiral Cine DENSE MRI [J].
Zhong, Xiaodong ;
Spottiswoode, Bruce S. ;
Meyer, Craig H. ;
Kramer, Christopher M. ;
Epstein, Frederick H. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) :1089-1097