Rapid and sensitive differentiation of anomers, linkage, and position isomers of disaccharides using High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS)

被引:109
作者
Gabryelski, W [1 ]
Froese, KL [1 ]
机构
[1] Univ Alberta, Dept Publ Hlth Sci, Edmonton, AB T6G 2G3, Canada
关键词
D O I
10.1016/S1044-0305(03)00002-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A challenging aspect of structural elucidation of carbohydrates is gaining unambiguous information for anomers, linkage, and position isomers. Such isomers with identical mass can't be easily distinguished in mass spectrometry and a separation step is required prior to mass spectrometry identification. In our laboratory, gas-phase separation and differentiation of anomers, linkage, and position isomers of disaccharides was achieved using High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS). The FAIMS method responds to changes in ion mobility at high field rather than absolute values of ion mobility, and was shown to provide efficient separation and identification of disaccharide isomers at high sensitivity. Separation of analyzed disaccharide isomers can be accomplished at low nM level in a matter of seconds without sample purification or fractionation. Capability for examining a large population of ionic species of disaccharides by this method allowed for correlating structural details of disaccharide isomers with their separation properties in FAIMS. Results for disaccharide isomers indicate that this method could be applied to a larger group of carbohydrates. (C) 2003 American Society for Mass Spectrometry.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 48 条
[1]  
Aspinall G. O., 1985, POLYSACCHARIDES, V3
[2]  
ASPINALL GO, 1982, POLYSACCHARIDES, V1
[3]  
ASPINALL GO, 1984, POLYSACCHARIDES, V2
[4]   Resolving isomeric peptide mixtures: A combined HPLC/ion mobility-TOFMS analysis of a 4000-component combinatorial library [J].
Barnes, CAS ;
Hilderbrand, AE ;
Valentine, SJ ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :26-36
[5]   Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry [J].
Barnett, DA ;
Ells, B ;
Guevremont, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (12) :1125-1133
[6]  
BJORNDAL HAKAN, 1967, CAR BOHYD RES, V5, P433, DOI 10.1016/S0008-6215(00)81115-5
[7]   A NEW METHOD OF SEPARATION OF MULTI-ATOMIC IONS BY MOBILITY AT ATMOSPHERIC-PRESSURE USING A HIGH-FREQUENCY AMPLITUDE-ASYMMETRIC STRONG ELECTRIC-FIELD [J].
BURYAKOV, IA ;
KRYLOV, EV ;
NAZAROV, EG ;
RASULEV, UK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03) :143-148
[8]   LIQUID SECONDARY-ION MASS-SPECTROMETRY FOURIER-TRANSFORM MASS-SPECTROMETRY OF OLIGOSACCHARIDE ANIONS [J].
CARROLL, JA ;
NGOKA, L ;
BEGGS, CG ;
LEBRILLA, CB .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1582-1587
[9]   OLIGOSACCHARIDE SEQUENCE DETERMINATION USING B/E LINKED FIELD SCANNING OR TANDEM MASS-SPECTROMETRY OF PHOSPHATIDYLETHANOLAMINE DERIVATIVES [J].
CHAI, W ;
CASHMORE, GC ;
STOLL, MS ;
GASKELL, SJ ;
ORKISZEWSKI, RS ;
LAWSON, AM .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (05) :313-323
[10]  
Clemmer DE, 1997, J MASS SPECTROM, V32, P577