A Machine Learning-Empowered System for Long-Term Motion-Tolerant Wearable Monitoring of Blood Pressure and Heart Rate With Ear-ECG/PPG

被引:81
作者
Zhang, Qingxue [1 ]
Zeng, Xuan [2 ]
Hu, Wenchuang [1 ]
Zhou, Dian [1 ,2 ]
机构
[1] Univ Texas Dallas, Dept Elect Engn, Richardson, TX 75080 USA
[2] Fudan Univ, Dept Microelect, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Wearable computers; blood pressure; heart rate; photoplethysmogram; electrocardiography; pulse transit time; fitness; signal processing; machine learning;
D O I
10.1109/ACCESS.2017.2707472
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we propose a fully ear-worn long-term blood pressure (BP) and heart rate (HR) monitor to achieve a higher wearability. Moreover, to enable practical application scenarios, we present a machine learning framework to deal with severe motion artifacts induced by head movements. We suggest situating all electrocardiogram (ECG) and photoplethysmography (PPG) sensors behind two ears to achieve a super wearability, and successfully acquire weak ear-ECG/PPG signals using a semi-customized platform. After introducing head motions toward real-world application scenarios, we apply a support vector machine classifier to learn and identify raw heartbeats from motion artifacts-impacted signals. Furthermore, we propose an unsupervised learning algorithm to automatically filter out residual distorted/faking heartbeats, for ECG-to-PPG pulse transit time (PTT) and HR estimation. Specifically, we introduce a dynamic time warping-based learning approach to quantify distortion conditions of raw heartbeats referring to a high-quality heartbeat pattern, which are then compared with a threshold to perform purification. The heartbeat pattern and the distortion threshold are learned by a K-medoids clustering approach and a histogram triangle method, respectively. Afterward, we perform a comparative analysis on ten PTT or PTT&HR-based BP learning models. Based on an acquired data set, the BP and HR estimation using the proposed algorithm has an error of -1.4 +/- 5.2 mmHg and 0.8 +/- 2.7 beats/min, respectively, both much lower than the state-of-the-art approaches. These results demonstrate the capability of the proposed machine learning-empowered system in ear-ECG/PPG acquisition and motion-tolerant BP/HR estimation. This proof-of-concept system is expected to illustrate the feasibility of ear-ECG/PPG-based motion-tolerant BP/HR monitoring.
引用
收藏
页码:10547 / 10561
页数:15
相关论文
共 31 条
[1]  
AAMI, 2007, SP101992 ANSIAAMI
[2]  
[Anonymous], 2007, P 18 ANN ACM SIAM S
[3]  
[Anonymous], 2012, ADS1299EEG FE EV BOA
[4]  
[Anonymous], 2010, IEEE REV BIOMED ENG, DOI DOI 10.1109/RBME.2010.2084078
[5]  
Birjandtalab J, 2015, 2015 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATION WORKSHOPS (PERCOM WORKSHOPS), P415, DOI 10.1109/PERCOMW.2015.7134074
[6]   A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time [J].
Buxi, Dilpreet ;
Redoute, Jean-Michel ;
Yuce, Mehmet Rasit .
PHYSIOLOGICAL MEASUREMENT, 2015, 36 (03) :R1-R26
[7]  
Cattivelli FS, 2009, SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, P114, DOI [10.1109/BSN.2009.35, 10.1109/P3644.34]
[8]   An Ear-Worn Vital Signs Monitor [J].
Da He, David ;
Winokur, Eric S. ;
Sodini, Charles G. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) :2547-2552
[9]  
Eriksson J., 2015, P IEEE INT C PERV CO, P1
[10]   A Robust Method to Estimate Instantaneous Heart Rate from Noisy Electrocardiogram Waveforms [J].
Gribok, Andrei V. ;
Chen, Xiaoxiao ;
Reifman, Jaques .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (02) :824-834