Strategies to increase sensitivity in UV-VIS spectrophotometry

被引:32
作者
Rocha, FRP
Teixeira, LSG
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
[2] Univ Salvador, Dept Engn & Arquitectura, BR-40220141 Salvador, BA, Brazil
来源
QUIMICA NOVA | 2004年 / 27卷 / 05期
关键词
UV-VIS spectrophotometry; long-pathlength spectrophotometry; solid-phase spectrophotometry;
D O I
10.1590/S0100-40422004000500021
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and How analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.
引用
收藏
页码:807 / 812
页数:6
相关论文
共 72 条
[1]  
[Anonymous], 1995, Standard methods for the examination of water and wastewater, V19th
[2]   TERNARY COMPLEXES IN ANALYTICAL CHEMISTRY [J].
BABKO, AK .
TALANTA, 1968, 15 (08) :721-&
[3]   ANALYTICAL APPLICATIONS OF TERNARY COMPLEXES .7. ELUCIDATION OF MODE OF FORMATION OF SENSITIZED METAL-CHELATE SYSTEMS AND DETERMINATION OF MOLYBDENUM AND ANTIMONY [J].
BAILEY, BW ;
CHESTER, JE ;
DAGNALL, RM ;
WEST, TS .
TALANTA, 1968, 15 (12) :1359-&
[4]   ANALYTICAL ASPECTS OF PHOTOACOUSTIC-SPECTROSCOPY [J].
BETTERIDGE, D ;
MEYLOR, PJ .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1984, 14 (04) :267-295
[5]   DETERMINATION OF VANADIUM BY SOLID-PHASE SPECTROPHOTOMETRY AFTER ITS PRECONCENTRATION AS AN ERIOCHROME-CYANINE-R COMPLEX ON A DEXTRAN-TYPE EXCHANGER [J].
BOUDRA, S ;
BOSQUESENDRA, JM ;
VALENCIA, MC .
TALANTA, 1995, 42 (10) :1525-1532
[7]   Construction of a compact spectrofluorometer/spectrophotometer system using a flexible liquid core waveguide [J].
Byrne, RH ;
Yao, WS ;
Kaltenbacher, E ;
Waterbury, RD .
TALANTA, 2000, 50 (06) :1307-1312
[8]   Long pathlength absorbance spectroscopy: trace copper analysis using a 4.4 m liquid core waveguide [J].
Callahan, MR ;
Rose, JB ;
Byrne, RH .
TALANTA, 2002, 58 (05) :891-898
[9]   FLOW-INJECTION METHOD FOR THE DETERMINATION OF TIN IN FRUIT JUICES USING SOLID-PHASE SPECTROPHOTOMETRY [J].
CAPITANVALLVEY, LF ;
VALENCIA, MC ;
MIRON, G .
ANALYTICA CHIMICA ACTA, 1994, 289 (03) :365-370
[10]   A SOLID-PHASE SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF SULFATHIAZOLE [J].
CAPITANVALLVEY, LF ;
DEORBE, I ;
VALENCIA, MC ;
BERZASNEVADO, JJ .
TALANTA, 1994, 41 (08) :1327-1333