The gamma camera as an absolute measurement device:: Determination of glomerular filtration rate in 99mTc-DTPA renography using a dual head gamma camera

被引:18
作者
Carlsen, O [1 ]
机构
[1] Vejle Hosp, Dept Clin Physiol & Nucl Med, DK-7100 Vejle, Denmark
关键词
Tc-99m-DTPA; renography; clearance; GFR; gamma camera methods;
D O I
10.1097/00006231-200410000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim The aim of this study was to design a general nuclear medicine method for fast, accurate and direct determination of the clearance of a radioactive indicator provided that all uptake compartments of the radioactive indicator could be included in the field of view of the gamma camera. Methods The data material for clearance calculation in the gamma camera method (GCM) comprises: (1) a transmission map of a part of the body using a water filled flood field phantom with a uniform distribution of the radioisotope, (2) the background corrected activity curves in the anterior and posterior views over all uptake compartments following the injection of the radioactive indicator, and (3) the activity of the radioactive indicator in at least two blood samples drawn during the examination. With a view to determining glomerular filtration rate (GFR) in Tc-99m-DTPA renography the gamma camera method was tested in a group of 26 adult subjects in whom GFR was determined simultaneously using the simplified multiple samples method (MSM) with plasma samples drawn 3-5 h following the injection of Cr-51-EDTA. Results For values of GFR above 30ml.min(-1) the regression line of GFR in the MSM versus GFR in the GCM was not significantly different from the line of identity. The reliability of the GCM alone was about 14%, 11% and 6% for GFR values of 30, 60 and 120ml.min(-1) and, therefore, the reliability of the GCM and the simplified MSM for prediction of GFR was almost the same. Conclusion Since the recording of the renal count rates in the anterior and posterior views permits an accurate determination of the split renal function, the GCM yields reliable estimates also of the single kidney GFR. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:1021 / 1029
页数:9
相关论文
共 22 条
[1]   COMPARISON BETWEEN TOTAL AND RENAL PLASMA CLEARANCE OF [EDTA-CR-51] [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (03) :247-249
[2]  
BROECHNERMORTEN.J, 1978, ROUTINE METHODS THEI
[3]   RENAL FRACTION OF CARDIAC-OUTPUT CLEARED OF RADIOACTIVE INDICATOR IN TC-99M-DTPA-GAMMA CAMERA RENOGRAPHY [J].
CARLSEN, O ;
NATHAN, E .
NUCLEAR MEDICINE COMMUNICATIONS, 1987, 8 (07) :489-497
[4]  
CARLSEN O, 2004, ALASBIMN J, V6
[5]   COMPARATIVE-ASSESSMENT OF TECHNIQUES FOR ESTIMATION OF GLOMERULAR-FILTRATION RATE WITH TC-99M-DTPA [J].
FAWDRY, RM ;
GRUENEWALD, SM ;
COLLINS, LT ;
ROBERTS, AJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (01) :7-12
[6]  
FLEMING JS, 1987, EUR J NUCL MED, V13, P250, DOI 10.1007/BF00252602
[8]  
GOATES JJ, 1990, J NUCL MED, V31, P424
[9]  
Inoue Y, 2000, J NUCL MED, V41, P823
[10]   Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA [J].
Itoh, K ;
Tsushima, S ;
Tsukamoto, E ;
Tamaki, N .
ANNALS OF NUCLEAR MEDICINE, 2000, 14 (03) :143-150