A Comparative Study of Single-pulse and Double-pulse Laser-Induced Breakdown Spectroscopy with Uranium-containing Samples

被引:32
|
作者
Skrodzki, Patrick J. [1 ]
Becker, Jason R. [1 ]
Diwakar, Prasoon K. [1 ]
Harilal, Sivanandan S. [2 ]
Hassanein, Ahmed [1 ]
机构
[1] Purdue Univ, Ctr Mat Extreme Environm CMUXE, Sch Nucl Engn, 400 Cent Dr, W Lafayette, IN 47907 USA
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
Double-pulse laser-induced breakdown spectroscopy; DPLIBS; Nuclear forensics; Uranium; Signal enhancement; Plasma diagnostics; WAVELENGTH; PLASMA; ENHANCEMENT; ABLATION; THORIUM;
D O I
10.1177/0003702815626670
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics, which require rapid analysis, minimal sample preparation, and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates the U signal in a glass matrix using DPLIBS and compares it to signal obtained using SPLIBS. Double-pulse LIBS involves sequential firing of a 1.06 mu m Nd:YAG pre-pulse and 10.6 mu m TEA CO2 heating pulse in a near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines for the bulk analyte Ca and the minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with a negligible increase in damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to the observed U analyte signal variation between SPLIBS and DPLIBS.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [41] Signal Enhancement in Target-Enhanced Orthogonal Double-Pulse Laser-Induced Breakdown Spectroscopy
    Lin Zehao
    Li Runhua
    Jiang Yinhua
    Chen Yuqi
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2021, 48 (24):
  • [42] In situ analysis of steel melt by double-pulse laser-induced breakdown spectroscopy with a Cassegrain telescope
    Sun, Lanxiang
    Yu, Haibin
    Cong, Zhibo
    Xin, Yong
    Li, Yang
    Qi, Lifeng
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 112 : 40 - 48
  • [43] Enhancement mechanism of femtosecond double-pulse laser-induced Cu plasma spectroscopy
    Zhang, Dan
    Chen, Anmin
    Wang, Xiaowei
    Li, Suyu
    Wang, Ying
    Sui, Laizhi
    Jiang, Yuanfei
    Jin, Mingxing
    OPTICS AND LASER TECHNOLOGY, 2017, 96 : 117 - 122
  • [44] Micro-destructive analysis with high sensitivity using double-pulse resonant laser-induced breakdown spectroscopy
    Tang, Zhiyang
    Zhou, Ran
    Hao, Zhongqi
    Ma, Shixiang
    Zhang, Wen
    Liu, Kun
    Li, Xiangyou
    Zeng, Xiaoyan
    Lu, Yongfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (06) : 1198 - 1204
  • [45] Measurement of chlorine concentration on steel surfaces via fiber-optic laser-induced breakdown spectroscopy in double-pulse configuration
    Xiao, X.
    Le Berre, S.
    Fobar, D. G.
    Burger, M.
    Skrodzki, P. J.
    Hartig, K. C.
    Motta, A. T.
    Jovanovic, I.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 141 : 44 - 52
  • [46] Role of laser pre-pulse wavelength and inter-pulse delay on signal enhancement in collinear double-pulse laser-induced breakdown spectroscopy
    Diwakar, P. K.
    Harilal, S. S.
    Freeman, J. R.
    Hassanein, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 : 65 - 73
  • [47] Quantitative Analysis of Manganese in Underwater Steel Samples Using Long-Short Double-Pulse Laser-Induced Breakdown Spectroscopy
    Wang, Zhenzhen
    Rong, Kai
    Tanaka, Seiya
    Deguchi, Yoshihiro
    Cui, Minchao
    Yan, Junjie
    APPLIED SPECTROSCOPY, 2021, 75 (11) : 1364 - 1373
  • [48] Determination of the limits of detection for aluminum-based alloys by spatially resolved single- and double-pulse laser-induced breakdown spectroscopy
    Sun, Duixiong
    Ma, Yunyun
    Wang, Yongqiang
    Su, Maogen
    Lu, Quanfang
    Dong, Chenzhong
    ANALYTICAL METHODS, 2018, 10 (22) : 2595 - 2603
  • [49] Comparison of Single Pulse and Double Simultaneous Pulse Laser Induced Breakdown Spectroscopy
    Haider, Zuhaib
    Bin Munajat, Yusof
    Kamarulzaman, Raja
    Shahami, Nurhidayu
    ANALYTICAL LETTERS, 2015, 48 (02) : 308 - 317
  • [50] In situ analysis of magnesium alloy using a standoff and double-pulse laser-induced breakdown spectroscopy system
    Xin, Yong
    Sun, Lan-Xiang
    Yang, Zhi-Jia
    Zeng, Peng
    Cong, Zhi-Bo
    Qi, Li-Feng
    FRONTIERS OF PHYSICS, 2016, 11 (05)