A Comparative Study of Single-pulse and Double-pulse Laser-Induced Breakdown Spectroscopy with Uranium-containing Samples

被引:33
作者
Skrodzki, Patrick J. [1 ]
Becker, Jason R. [1 ]
Diwakar, Prasoon K. [1 ]
Harilal, Sivanandan S. [2 ]
Hassanein, Ahmed [1 ]
机构
[1] Purdue Univ, Ctr Mat Extreme Environm CMUXE, Sch Nucl Engn, 400 Cent Dr, W Lafayette, IN 47907 USA
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
Double-pulse laser-induced breakdown spectroscopy; DPLIBS; Nuclear forensics; Uranium; Signal enhancement; Plasma diagnostics; WAVELENGTH; PLASMA; ENHANCEMENT; ABLATION; THORIUM;
D O I
10.1177/0003702815626670
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics, which require rapid analysis, minimal sample preparation, and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates the U signal in a glass matrix using DPLIBS and compares it to signal obtained using SPLIBS. Double-pulse LIBS involves sequential firing of a 1.06 mu m Nd:YAG pre-pulse and 10.6 mu m TEA CO2 heating pulse in a near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines for the bulk analyte Ca and the minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with a negligible increase in damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to the observed U analyte signal variation between SPLIBS and DPLIBS.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 25 条
[21]   Differential laser absorption spectroscopy of uranium in an atmospheric pressure laser-induced plasma [J].
Taylor, N. R. ;
Phillips, M. C. .
OPTICS LETTERS, 2014, 39 (03) :594-597
[22]   Basic mechanisms of signal enhancement in ns double-pulse laser-induced breakdown spectroscopy in a gas environment [J].
Tognoni, Elisabetta ;
Cristoforetti, Gabriele .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) :1318-1338
[23]   Nd:YAG-CO2 double-pulse laser induced breakdown spectroscopy of organic films [J].
Weidman, Matthew ;
Baudelet, Matthieu ;
Palanco, Santiago ;
Sigman, Michael ;
Dagdigian, Paul J. ;
Richardson, Martin .
OPTICS EXPRESS, 2010, 18 (01) :259-266
[24]   Thermodynamic and spectroscopic properties of Nd:YAG-CO2 Double-Pulse Laser-induced Iron Plasmas [J].
Weidman, Matthew ;
Palanco, Santiago ;
Baudelet, Matthieu ;
Richardson, Martin C. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (10) :961-967
[25]   Prospects for the introduction of wide area monitoring using environmental sampling for proliferation detection [J].
Wogman, Ned A. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) :1071-1077