Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction

被引:8
作者
Pan, Yu-Ning [1 ,2 ]
Li, Ai-Jing [3 ]
Chen, Zhao-Qian [1 ,2 ]
Ren, Da-Wei [1 ]
Zhang, Jie [1 ]
Jiang, Mao-Qing [1 ]
Huang, Qiu-Li [1 ]
机构
[1] Ningbo First Hosp, Dept Radiol, 59 Liuting Rd, Ningbo, Zhejiang, Peoples R China
[2] Ningbo Univ, Dept Med Coll, Ningbo 315211, Zhejiang, Peoples R China
[3] Ningbo 2 Hosp, Dept Radiol, Ningbo, Zhejiang, Peoples R China
关键词
lower extremity; angiography; radiation dose; image noise; iterative reconstruction; DIGITAL-SUBTRACTION-ANGIOGRAPHY; ROW CT ANGIOGRAPHY; REDUCTION; EXPOSURE; ARTERIES; DISEASE;
D O I
10.1097/RCT.0000000000000356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of the study was to investigate the feasibility of low-tube-voltage computed tomography (CT) in combination with 3-dimensional adaptive iterative dose reduction (AIDR-3D) algorithm in lower extremity CT angiography. Methods The CT data of the 120-kV group (n = 30) were reconstructed with filtered back projection (FBP) algorithm. The CT data of the 100-kV group (n = 30) were reconstructed with FBP as well as AIDR-3D algorithms. Results The 100-kV group showed significantly lower dose-length product than the 120-kV group (P < 0.05). In comparison with the 120-kV and FBP protocol, the 100-kV and FBP protocol showed significantly increased vascular density and noise (P < 0.05). However, in the 100-kV group, images reconstructed with AIDR-3D showed significantly lower noise and significantly higher signal-to-noise ratio and contrast-to-noise ratio than FBP (P < 0.05). Conclusions Low-tube-voltage (100 kV) 320-row CT in combination with AIDR-3D reconstruction can significantly improve the image quality and reduce radiation dose of lower extremity CT angiography.
引用
收藏
页码:272 / 276
页数:5
相关论文
共 50 条
[1]   Radiation dose and image quality with new protocol in lower extremity computed tomography angiography [J].
Schicchi, Nicolo ;
Fogante, Marco ;
Oliva, Matteo ;
Pirani, Paolo Esposto ;
Agliata, Giacomo ;
Giuseppetti, Gian Marco ;
Giovagnoni, Andrea .
RADIOLOGIA MEDICA, 2019, 124 (03) :184-190
[2]   Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography [J].
Mousavi-Gazafroudi, Seyedeh Shokoofeh ;
Sajjadieh-Khajouei, Amirreza ;
Moradi, Maryam ;
Mousavi-Gazafroudi, Seyedeh Shabnam ;
Yadegarfar, Ghasem ;
Tavakoli, Mohammad Bagher .
ARYA ATHEROSCLEROSIS, 2019, 15 (05) :205-210
[3]   Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm-Initial Clinical Experience [J].
Marin, Daniele ;
Nelson, Rendon C. ;
Schindera, Sebastian T. ;
Richard, Samuel ;
Youngblood, Richard S. ;
Yoshizumi, Terry T. ;
Samei, Ehsan .
RADIOLOGY, 2010, 254 (01) :145-153
[4]   A Hybrid Iterative Reconstruction Algorithm That Improves the Image Quality of Low-Tube-Voltage Coronary CT Angiography [J].
Oda, Seitaro ;
Utsunomiya, Daisuke ;
Funama, Yoshinori ;
Yonenaga, Kazuchika ;
Namimoto, Tomohiro ;
Nakaura, Takeshi ;
Yamashita, Yasuyuki .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) :1126-1131
[5]   Evaluation of Deep Vein Thrombosis With Reduced Radiation and Contrast Material Dose at Computed Tomography Venography - Clinical Application of a Combined Iterative Reconstruction and Low-Tube-Voltage Technique [J].
Oda, Seitaro ;
Utsunomiya, Daisuke ;
Funama, Yoshinori ;
Shimonobo, Toshiaki ;
Namimoto, Tomohiro ;
Itatani, Ryo ;
Hirai, Toshinori ;
Yamashita, Yasuyuki .
CIRCULATION JOURNAL, 2012, 76 (11) :2614-2622
[6]   Radiation dose and image quality with new protocol in lower extremity computed tomography angiography [J].
Nicolò Schicchi ;
Marco Fogante ;
Matteo Oliva ;
Paolo Esposto Pirani ;
Giacomo Agliata ;
Gian Marco Giuseppetti ;
Andrea Giovagnoni .
La radiologia medica, 2019, 124 :184-190
[7]   Reducing radiation dose in the diagnosis of pulmonary embolism using adaptive statistical iterative reconstruction and lower tube potential in computed tomography [J].
Kaul, David ;
Grupp, Ulrich ;
Kahn, Johannes ;
Ghadjar, Pirus ;
Wiener, Edzard ;
Hamm, Bernd ;
Streitparth, Florian .
EUROPEAN RADIOLOGY, 2014, 24 (11) :2685-2691
[8]   Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose [J].
Chen, Chih-Wei ;
Chen, Po-An ;
Chou, Chiung-Chen ;
Fu, Jui-Hsun ;
Wang, Po-Chin ;
Hsu, Shuo-Hsiu ;
Lai, Ping-Hong .
ACADEMIC RADIOLOGY, 2019, 26 (08) :E233-E240
[9]   Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography [J].
Sato, Jiro ;
Akahane, Masaaki ;
Inano, Sachiko ;
Terasaki, Mariko ;
Akai, Hiroyuki ;
Katsura, Masaki ;
Matsuda, Izuru ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (02) :146-153
[10]   Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography [J].
Noel, Peter B. ;
Koehler, Thomas ;
Fingerle, Alexander A. ;
Brown, Kevin M. ;
Zabic, Stanislav ;
Muenzel, Daniela ;
Haller, Bernhard ;
Baum, Thomas ;
Henninger, Martin ;
Meier, Reinhard ;
Rummeny, Ernst J. ;
Dobritz, Martin .
JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)