Mechanical properties of high-strength concrete after fire

被引:218
作者
Min, L [1 ]
Qian, CX [1 ]
Wei, S [1 ]
机构
[1] SE Univ, Dept Mat Sci & Engn, Nanjing 210096, Jiangsu, Peoples R China
关键词
high-strength concrete; fire; mechanical properties;
D O I
10.1016/j.cemconres.2003.11.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With compressive strength grade of C40, C60, and C70, respectively, normal-strength concrete (NSC) and high-strength concrete (HSC) were used to investigate compressive strength, splitting tensile strength, and bending strength after high temperature. The oil furnace is used in this study. Its temperature-time curve is close to standard curve, which conforms to Chinese standard GB/T 9978-1999. After being heated to temperatures of 200, 400, 600, 800, and 1000 degreesC, respectively, the mechanical properties of HSC were tested. The influence of temperature, water content, specimen size, strength grade, and temperature profiles on mechanical properties of HSC are discussed. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 7 条
[1]   Explosive spalling of high-strength concrete columns in fire [J].
Ali, FA ;
O'Connor, D ;
Abu-Tair, A .
MAGAZINE OF CONCRETE RESEARCH, 2001, 53 (03) :197-204
[2]  
Bo W., 2000, J CIVIL ENG, V33, P8
[3]  
LUO X, 2001, THESIS SE U, P33
[4]  
PENG GF, CONCRETE, V2, P16
[5]  
SANJAYAN G, 1993, ACI MATER J, V90, P170
[6]  
Shah S. P., 1994, HIGH PERFORMANCE CON
[7]  
WU ZP, 1999, FIRE STANDARD BUILDI