Cyclic steady state stress-strain behavior of UHMW polyethylene

被引:54
作者
Krzypow, DJ
Rimnac, CM
机构
[1] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Orthopaed, Cleveland, OH 44106 USA
关键词
ultra high molecular weight polyethylene; UHMWPE; cycle-dependent stability; fatigue; mechanical performance;
D O I
10.1016/S0142-9612(00)00138-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To increase the long-term performance of total joint replacements, finite element analyses of ultra high molecular weight polyethylene (UHMWPE) components have been conducted to predict the effect of load on the stress and strain distributions occurring on and within these components. Early models incorporated the monotonic behavior of UHMWPE without considering the unloading and cyclic loading behavior. However, UHMWPE components undergo cyclic loading during use and at least two wear damage modes (pitting and delamination) are thought to be associated with the fatigue fracture properties of UHMWPE. The objective of this study was to examine the fully reversed uniaxial tension/compression cyclic steady state stress-strain behavior of UHMWPE as a first step towards developing a cyclic constitutive relationship for UHMWPE. The hypothesis that cycling results in a permanent change in the stress-strain relationship, that is, that the cyclic steady state represents a new cyclically stabilized state, was examined. It was found that, like other ductile polymers, UHMWPE substantially cyclically softens under fully reversed uniaxial straining. More cyclic softening occurred in tension than in compression. Furthermore, cyclic steady state was attained, but not cyclic stability. It is suggested that it may be more appropriate to base a material constitutive relationship for UHMWPE for finite element analyses of components upon a cyclically modified stress-strain relationship. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2081 / 2087
页数:7
相关论文
共 28 条
[1]   PERFORMANCE OF THE TIBIAL COMPONENT IN TOTAL KNEE REPLACEMENT - CONVENTIONAL AND REVISION DESIGNS [J].
BARTEL, DL ;
BURSTEIN, AH ;
SANTAVICCA, EA ;
INSALL, JN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1026-1033
[2]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[3]  
BARTEL DL, 1991, BRIS MYER Z, P61
[4]  
BARTEL DL, 1995, CLIN ORTHOP RELAT R, P76
[5]  
BELLARE A, 1996, T ORTHOP RES SOC, V21, P495
[6]  
BENNETT AP, 1996, T 42 ORTH RES SOC AT
[7]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[8]  
DANNENMAIER WC, 1985, CLIN ORTHOP RELAT R, P224
[9]   FATIGUE-CRACK PROPAGATION BEHAVIOR OF ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE UNDER MIXED-MODE CONDITIONS [J].
ELBERT, KE ;
WRIGHT, TM ;
RIMNAC, CM ;
KLEIN, RW ;
INGRAFFEA, AR ;
GUNSALLUS, K ;
BARTEL, DL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (02) :181-187
[10]   Residual stresses in ultra-high molecular weight polyethylene loaded cyclically by a rigid moving indenter in nonconforming geometries [J].
Estupiñán, JA ;
Bartel, DL ;
Wright, TM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (01) :80-88