High contrast cartilaginous endplate imaging using a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence

被引:7
作者
Lombardi, Alecio F. [1 ,2 ]
Wei, Zhao [1 ]
Wong, Jonathan [1 ,2 ]
Carl, Michael [3 ]
Lee, Roland R. [1 ]
Wallace, Mark [4 ]
Masuda, Koichi [5 ]
Chang, Eric Y. [1 ,2 ]
Du, Jiang [1 ]
Ma, Ya-Jun [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, 9452 Med Ctr Dr, San Diego, CA 92037 USA
[2] Vet Affairs San Diego Healthcare Syst, Res Serv, San Diego, CA USA
[3] GE Healthcare, San Diego, CA USA
[4] Univ Calif San Diego, Dept Anesthesiol, San Diego, CA 92103 USA
[5] Univ Calif San Diego, Dept Orthoped Surg, San Diego, CA 92103 USA
关键词
adiabatic inversion recovery; cartilaginous endplate; ultrashort echo time; VERTEBRAL ENDPLATE; MRI; EXCITATION; DISEASE; SPINE;
D O I
10.1002/nbm.4579
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Ultrashort echo time (UTE) sequences can image tissues with transverse T (2)/T (2)* relaxations too short to be efficiently observed on routine clinical MRI sequences, such as the vertebral body cartilaginous endplate (CEP). Here, we describe a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence to highlight the CEP of vertebral bodies in comparison to the intervertebral disc (IVD) and bone marrow fat (BF) at 3 T. The IR-FS-UTE sequence used a 3D UTE sequence combined with an adiabatic IR preparation pulse centered in the middle of the water and fat peaks, while a fat saturation module was used to suppress the signal from fat. A slab-selective half pulse was used for signal excitation, and a 3D center-out cones trajectory was used for more efficient data sampling. The 3D IR-FS-UTE sequence was applied to an ex vivo human spine sample, as well as the spines of six healthy volunteers and of three patients with back pain. Bright continuous lines representing signal from CEP were found in healthy IVDs. The measured contrast-to-noise ratio was 18.5 +/- 4.9 between the CEP and BF, and 20.3 +/- 4.15 between the CEP and IVD for the six volunteers. Abnormal IVDs showed CEP discontinuity or irregularity in the sample and patient studies. In conclusion, the proposed 3D IR-FS-UTE sequence is feasible for imaging the vertebral body's CEP in vivo with high contrast.
引用
收藏
页数:11
相关论文
共 31 条
[11]   Design and analysis of a practical 3D cones trajectory [J].
Gurney, PT ;
Hargreaves, BA ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :575-582
[12]   Variable-rate selective excitation for rapid MRI sequences [J].
Hargreaves, BA ;
Cunningham, CH ;
Nishimura, DG ;
Conolly, SM .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :590-597
[13]   The Epidemiology of low back pain [J].
Hoy, D. ;
Brooks, P. ;
Blyth, F. ;
Buchbinder, R. .
BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2010, 24 (06) :769-781
[14]   Biomechanics of Intervertebral Disk Degeneration [J].
Inoue, Nozomu ;
Orias, Alejandro A. Espinoza .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (04) :487-+
[15]   Cartilaginous endplates of the spine: MRI with anatomic correlation in cadavers [J].
Kakitsubata, Y ;
Theodorou, DJ ;
Theodorou, SJ ;
Tamura, S ;
Nabeshima, K ;
Trudell, D ;
Clopton, PL ;
Resnick, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) :933-940
[16]   Atherosclerosis and Disc Degeneration/Low-Back Pain - A Systematic Review [J].
Kauppila, L. I. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 37 (06) :661-670
[17]   Proton-density fat fraction and simultaneous R2*estimation as an MRI tool for assessment of osteoporosis [J].
Kuehn, Jens-Peter ;
Hernando, Diego ;
Meffert, Peter J. ;
Reeder, Scott ;
Hosten, Norbert ;
Laqua, Rene ;
Steveling, Antje ;
Ender, Stephan ;
Schroeder, Henry ;
Pillich, Dirk-Thomas .
EUROPEAN RADIOLOGY, 2013, 23 (12) :3432-3439
[18]   Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging [J].
Larson, Peder E. Z. ;
Conolly, Steven M. ;
Pauly, John M. ;
Nishimura, Dwight G. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :952-961
[19]   Weighted subtraction in 3D ultrashort echo time (UTE) imaging for visualization of short T2 tissues of the knee [J].
Lee, Young Han ;
Kim, Sungjun ;
Song, Ho-Taek ;
Kim, InSeong ;
Suh, Jin-Suck .
ACTA RADIOLOGICA, 2014, 55 (04) :454-461
[20]   Sparse MRI: The application of compressed sensing for rapid MR imaging [J].
Lustig, Michael ;
Donoho, David ;
Pauly, John M. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) :1182-1195