Joint Reconstruction of Multi-contrast Images and Multi-channel Coil Sensitivities

被引:1
作者
Chen, Zhongzhou [1 ,2 ]
Ren, Yanan [1 ,3 ]
Su, Shi [1 ]
Shi, Caiyun [1 ]
Ji, Jim X. [4 ]
Zheng, Hairong [1 ]
Liu, Xin [1 ]
Xie, Guoxi [5 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[3] Northeastern Univ, Sino Dutch Biomed & Informat Engn Sch, Shenyang, Peoples R China
[4] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX USA
[5] Guangzhou Med Univ, Sch Basic Sci, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
COMPRESSED SENSING MRI; ACQUISITION;
D O I
10.1007/s00723-017-0919-4
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Magnetic resonance imaging (MRI) has an important feature that it provides multiple images with different contrasts for complementary diagnostic information. However, a large amount of data is needed for multi-contrast images depiction, and thus, the scan is time-consuming. Many methods based on parallel magnetic resonance imaging (pMRI) and compressed sensing (CS) are applied to accelerate multi-contrast MR imaging. Nevertheless, the image reconstructed by sophisticated pMRI methods contains residual aliasing artifact that degrades the quality of the image when the acceleration factor is high. Other methods based on CS always suffer the regularization parameter-selecting problem. To address these issues, a new method is presented for joint multi-contrast image reconstruction and coil sensitivity estimation. The coil sensitivities can be shared during the reconstruction due to the identity of coil sensitivity profiles of different contrast images for imaging stationary tissues. The proposed method uses the coil sensitivities as sharable information during the reconstruction to improve the reconstruction quality. As a result, the residual aliasing artifact can be effectively removed in the reconstructed multi-contrast images even if the acceleration factor is high. Besides, as there is no regularization term in the proposed method, the troublesome regularization parameter selection in the CS can also be avoided. Results from multi-contrast in vivo experiments demonstrated that multi-contrast images can be jointly reconstructed by the proposed method with effective removal of the residual aliasing artifact at a high acceleration factor.
引用
收藏
页码:955 / 969
页数:15
相关论文
共 27 条
[1]  
[Anonymous], 2009, ARXIV09061487
[2]   Multi-contrast Reconstruction With Bayesian Compressed Sensing [J].
Bilgic, Berkin ;
Goyal, Vivek K. ;
Adalsteinsson, Elfar .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) :1601-1615
[3]   Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1086-1098
[4]  
Chatnuntawech I., 2015, 12 INT S BIOM IM, P335, DOI [10.1109/ISBI.2015.7163881, DOI 10.1109/ISBI.2015.7163881]
[5]   Vectorial total generalized variation for accelerated multi-channel multi-contrast MRI [J].
Chatnuntawech, Itthi ;
Martin, Adrian ;
Bilgic, Berkin ;
Setsompop, Kawin ;
Adalsteinsson, Elfar ;
Schiavi, Emanuele .
MAGNETIC RESONANCE IMAGING, 2016, 34 (08) :1161-1170
[6]  
Chen C., 2014, 11 INT S BIOM IM, P41, DOI [10.1109/ISBI.2014.6867804, DOI 10.1109/ISBI.2014.6867804]
[7]   PROMISE: Parallel-Imaging and Compressed-Sensing Reconstruction of Multicontrast Imaging Using SharablE Information [J].
Gong, Enhao ;
Huang, Feng ;
Ying, Kui ;
Wu, Wenchuan ;
Wang, Shi ;
Yuan, Chun .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) :523-+
[8]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[9]   METHODS OF CONJUGATE GRADIENTS FOR SOLVING LINEAR SYSTEMS [J].
HESTENES, MR ;
STIEFEL, E .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1952, 49 (06) :409-436
[10]  
Huang J., 2012, ISBI, DOI [10.1109/ISBI.2012.6235718, DOI 10.1109/ISBI.2012.6235718]