Dynamic Low Voltage Ride through Detection and Mitigation in Brushless Doubly Fed Induction Generators

被引:5
作者
Memon, Ahsanullah [1 ,2 ]
Mustafa, Mohd Wazir [1 ]
Aman, Muhammad Naveed [3 ]
Ullah, Mukhtar [4 ]
Kamal, Tariq [5 ]
Hafeez, Abdul [6 ]
机构
[1] Univ Teknol Malaysia, Fac Engn, Sch Elect Engn, Skudai 81310, Johor, Malaysia
[2] Mehran Univ Elect & Technol, Dept Elect Engn, SZAB Campus, Khairpur Mir 66020, Sindh, Pakistan
[3] Natl Univ Singapore, Sch Comp, Singapore 117417, Singapore
[4] Natl Univ Comp & Emerging Sci, Dept Elect Engn, Islamabad 44000, Islamabad Capit, Pakistan
[5] Univ Engn & Technol Peshawar, Dept Comp Syst Engn, Peshawar 25000, Khyber Pakhtunk, Pakistan
[6] Univ Engn & Technol Peshawar, Comp Sci & Informat Technol, Jalozai Campus, Peshawar 25120, Khyber Pakhtunk, Pakistan
关键词
low voltage ride through; reactive power control; short-circuit faults; wind energy; REACTIVE CURRENT; ENHANCEMENT; CAPABILITY;
D O I
10.3390/en14154461
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Brushless doubly-fed induction generators have higher reliability, making them an attractive choice for not only offshore applications but also for remote locations. These machines are composed of two back-to-back voltage source converters: the grid side converter and the rotor side converter. The rotor side converter is typically used for reactive current control of the power winding using the control winding current. A low voltage ride through (LVRT) fault is detected using a hysterisis comparison of the power winding voltage. This approach leads to two problems, firstly, the use of only voltage to detect faults results in erroneous or slow response, and secondly, sub-optimal control of voltage drop because of static reference values for reactive current compensation. This paper solves these problems by using an analytical model of the voltage drop caused by a short circuit. Moreover, using a fuzzy logic controller, the proposed technique employs the voltage frequency in addition to the power winding voltage magnitude to detect LVRT conditions. The analytical model helps in reducing the power winding voltage drop while the fuzzy logic controller leads to better and faster detection of faults, leading to an overall faster response of the system. Simulations in Matlab/Simulink show that the proposed technique can reduce the voltage drop by up to 0.12 p.u. and result in significantly lower transients in the power winding voltage as compared to existing techniques.
引用
收藏
页数:17
相关论文
共 50 条
[31]   Study of Low-Voltage Ride-Through Performance for Wind Power Generation with Doubly Fed Induction Generator [J].
Hirawata, Ryoya ;
Kai, Takaaki .
ELECTRICAL ENGINEERING IN JAPAN, 2013, 185 (01) :17-26
[32]   Dynamic Behavior of Doubly Fed Induction Generator during Network Voltage Dips [J].
Metatla, S. ;
Mekhtoub, S. ;
Ibtiouen, R. ;
Nesba, A. .
2014 INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2014,
[33]   Optimal Control of Brushless Doubly Fed Wind Power Generator under Zero-Voltage Ride-Through [J].
Xu, Junyang ;
Nie, Pengcheng .
ENERGIES, 2024, 17 (01)
[34]   Grid-fault ride-through analysis and control of wind turbines with doubly fed induction generators [J].
Rahimi, Mohsen ;
Parniani, Mostafa .
ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (02) :184-195
[35]   Low voltage ride through of doubly-fed induction generator connected to the grid using sliding mode control strategy [J].
Saad, Naggar H. ;
Sattar, Ahmed A. ;
Mansour, Abd El-Aziz M. .
RENEWABLE ENERGY, 2015, 80 :583-594
[36]   Low voltage ride-through strategies for doubly fed induction machine pumped storage system under grid faults [J].
Damdoum, Amel ;
Slama-Belkhodja, Ilhem ;
Pietrzak-David, Maria ;
Debbou, Mustapha .
RENEWABLE ENERGY, 2016, 95 :248-262
[37]   Control Strategies of Doubly Fed Induction Generators to Support Grid Voltage [J].
Salles, M. B. C. ;
Cardoso, J. R. ;
Grilo, A. P. ;
Rahmann, C. ;
Hameyer, K. .
2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, :1551-1551
[38]   Low voltage ride through control strategy of VSG controlled doubly fed wind turbine [J].
Wang X.-D. ;
Zhang A. ;
Li S.-L. ;
Song P. ;
Zhang Y.-F. ;
Zhang X.-G. .
Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (03) :21-29
[39]   Low voltage ride-through of DFIG and brushless DFIG: Similarities and differences [J].
Tohidi, S. ;
Tavner, P. ;
McMahon, R. ;
Oraee, H. ;
Zolghadri, M. R. ;
Shao, S. ;
Abdi, E. .
ELECTRIC POWER SYSTEMS RESEARCH, 2014, 110 :64-72
[40]   Computational Analysis on Doubly Fed Induction Generator to determine Core Loss under normal and Low Voltage Ride Through (LVRT) Condition [J].
Nikita, T. ;
Manickavasagam, K. ;
Sachin, S. .
PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY (TAP ENERGY): EXPLORING ENERGY SOLUTIONS FOR AN INTELLIGENT POWER GRID, 2017,