Theoretical and experimental estimation of limiting input heat flux for thermoelectric power generators with passive cooling

被引:45
作者
Date, Ashwin [1 ]
Date, Abhijit [1 ]
Dixon, Chris [1 ]
Singh, Randeep [2 ]
Akbarzadeh, Aliakbar [1 ]
机构
[1] RMIT Univ, Sch Aerosp Mech & Mfg Engn, Bundoora, Vic 3083, Australia
[2] Fujikura Ltd, Thermal Engn Div, Tokyo 135, Japan
关键词
Limiting heat flux; Conventional heat sink; Thermoelectric generator; Passive heat sink; PERFORMANCE;
D O I
10.1016/j.solener.2014.10.043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper focuses on theoretical and experimental analysis used to establish the limiting heat flux for passively cooled thermoelectric generators (TEG). 2 commercially available TEG's further referred as type A and type B with different allowable hot side temperatures (150 degrees C and 250 degrees C respectively) were investigated in this research. The thermal resistance of TEG was experimentally verified against the manufacturer's specifications and used for theoretical analysis in this paper. A theoretical model is presented to determine the maximum theoretical heat flux capacity of both the TEG's. The conventional methods are used for cooling of TEG's and actual limiting heat flux is experimentally established for various cold end cooling configurations namely bare plate, finned block and heat pipe with finned condenser. Experiments were performed on an indoor setup and outdoor setup to validate the results from the theoretical model. The outdoor test setup consist of a fresnel lens solar concentrator with manual two axis solar tracking system for varying the heat flux, whereas the indoor setup uses electric heating elements to vary the heat flux and a low speed wind tunnel blows the ambient air past the device to simulate the outdoor breezes. It was observed that bare plate cooling can achieve a maximum heat flux of 18,125 W/m(2) for type A and 31,195 W/m(2) for type B at ambient wind speed of 5 m/s while maintaining respective allowable temperature over the hot side of TEG's. Fin geometry was optimised for the finned block cooling by using the fin length and fin gap optimisation model presented in this paper. It was observed that an optimum finned block cooling arrangement can reach a maximum heat flux of 26,067 W/m(2) for type A and 52,251 W/m(2) for type B TEG at ambient wind speed of 5 m/s of ambient wind speed. The heat pipe with finned condenser used for cooling can reach 40,375 W/m(2) for type A TEG and 76,781 W/m(2) for type B TEG. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 217
页数:17
相关论文
共 29 条
[1]  
[Anonymous], 2007, Introduction to Heat Transfer
[2]   Concentrated solar thermoelectric generators [J].
Baranowski, Lauryn L. ;
Snyder, G. Jeffrey ;
Toberer, Eric S. .
ENERGY & ENVIRONMENTAL SCIENCE, 2012, 5 (10) :9055-9067
[3]   Study of a TE (thermoelectric) generator incorporated in a multifunction wood stove [J].
Champier, D. ;
Bedecarrats, J. P. ;
Kousksou, T. ;
Rivaletto, M. ;
Strub, F. ;
Pignolet, P. .
ENERGY, 2011, 36 (03) :1518-1526
[4]   Thermoelectric power generation from biomass cook stoves [J].
Champier, D. ;
Bedecarrats, J. P. ;
Rivaletto, M. ;
Strub, F. .
ENERGY, 2010, 35 (02) :935-942
[5]  
Date A., 2011, THEORETICAL ANAL DET
[6]   New directions for low-dimensional thermoelectric materials [J].
Dresselhaus, Mildred S. ;
Chen, Gang ;
Tang, Ming Y. ;
Yang, Ronggui ;
Lee, Hohyun ;
Wang, Dezhi ;
Ren, Zhifeng ;
Fleurial, Jean-Pierre ;
Gogna, Pawan .
ADVANCED MATERIALS, 2007, 19 (08) :1043-1053
[7]  
Drosg M., 2009, DEALING UNCERTAINTIE, V2nd
[8]  
Ewert M.K., 1998, TERRESTRIAL AEROSPAC, V98
[9]   Electric Power Generation from Thermoelectric Cells Using a Solar Dish Concentrator [J].
Fan, Hongnan ;
Singh, Randeep ;
Akbarzadeh, Aliakbar .
JOURNAL OF ELECTRONIC MATERIALS, 2011, 40 (05) :1311-1320
[10]  
Fuqiang W., 2014, SOL ENERGY, V108, P348, DOI DOI 10.1016/J.SOLENER.2014.07.016