HoloNeedle: Augmented Reality Guidance System for Needle Placement Investigating the Advantages of Three-Dimensional Needle Shape Reconstruction

被引:30
作者
Lin, Michael A. [1 ]
Siu, Alexa F. [1 ]
Bae, Jung Hwa [1 ]
Cutkosky, Mark R. [1 ]
Daniel, Bruce L. [2 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
Virtual reality and interfaces; medical robots and systems; surgical robotics; steerable catheters/needles; IMAGE GUIDANCE; VISUALIZATION; ANESTHESIA; BIOPSIES; SURGERY;
D O I
10.1109/LRA.2018.2863381
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Augmented reality (AR) systems have been proposed for medical needle procedures as alternatives to restore the physician's natural perspective and head motion parallax that are lost when using standard imaging methods. AR systems have assumed a rigid needle, but in practice, a needle can experience large deflections that can lead to significant errors. We combine an instrumented needle that measures bending deflections with optical tracking of the needle base for precision and an AR system to provide users with precise three-dimensional rendering of needle motion and deflection inside a body. In controlled tests, users guided a needle through 7 cm of tissue phantom to reach a 2-mm diameter target. We found that displaying needle shape allows users significantly reduce placement errors when compared to the rigid needle assumption. In addition, a new display technique called tip tangent extrapolation, based on the sensed needle endpoint and direction, allowed users to further reduce errors resulting in 26% less error when compared to a rigid needle assumption.
引用
收藏
页码:4156 / 4162
页数:7
相关论文
共 17 条
[1]   Simulator for teaching handeye coordination during ultrasound-guided regional anaesthesia [J].
Adhikary, S. D. ;
Hadzic, A. ;
McQuillan, P. M. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (05) :844-845
[2]  
Azuma R., 1994, Computer Graphics Proceedings. Annual Conference Series 1994. SIGGRAPH 94 Conference Proceedings, P197, DOI 10.1145/192161.192199
[3]   Transperineal prostate biopsy under magnetic resonance image guidance: A needle placement accuracy study [J].
Blumenfeld, Philip ;
Hata, Nobuhiko ;
DiMaio, Simon ;
Zou, Kelly ;
Haker, Steven ;
Fichtinger, Gabor ;
Tempany, Clare M. C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) :688-694
[4]   Breast Biopsies Under Magnetic Resonance Imaging Guidance: Challenges of an Essential but Imperfect Technique [J].
Chevrier, Marie-Claude ;
David, Julie ;
El Khoury, Mona ;
Lalonde, Lucie ;
Labelle, Maude ;
Trop, Isabelle .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2016, 45 (03) :193-204
[5]  
Elayaperumal S, 2013, 2013 WORLD HAPTICS CONFERENCE (WHC), P109, DOI 10.1109/WHC.2013.6548393
[6]  
Fuchs H, 1996, LECT NOTES COMPUT SC, V1131, P591, DOI 10.1007/BFb0047002
[7]  
Fuchs H, 1998, LECT NOTES COMPUT SC, V1496, P934, DOI 10.1007/BFb0056282
[8]  
Khamene A, 2003, STUD HEALTH TECHNOL, V94, P151
[9]   The effect of anesthesia type on needle localization breast biopsy: Another point of view [J].
Papa, MZ ;
Klein, E ;
Davidson, B ;
Karni, T ;
Sperber, F ;
Koller, M ;
Ravid, M ;
BenAri, G .
AMERICAN JOURNAL OF SURGERY, 1996, 171 (02) :242-243
[10]   Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions [J].
Park, Yong-Lae ;
Elayaperumal, Santhi ;
Daniel, Bruce ;
Ryu, Seok Chang ;
Shin, Mihye ;
Savall, Joan ;
Black, Richard J. ;
Moslehi, Behzad ;
Cutkosky, Mark R. .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2010, 15 (06) :906-915