Removing Muscle Artifacts From EEG Data via Underdetermined Joint Blind Source Separation: A Simulation Study

被引:17
|
作者
Zou, Liang [1 ,2 ]
Chen, Xun [3 ]
Dang, Ge [4 ]
Guo, Yi [4 ]
Wang, Z. Jane [2 ]
机构
[1] China Univ Min & Technol, Sch Informat & Control Engn, Xuzhou 221100, Jiangsu, Peoples R China
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[3] Univ Sci & Technol China, Dept Elect Sci & Technol, Hefei 230000, Anhui, Peoples R China
[4] Jinan Univ, Shenzhen Peoples Hosp, Clin Med Coll 2, Dept Neurol, Shenzhen 518020, Guangdong, Peoples R China
基金
中国国家自然科学基金; 加拿大自然科学与工程研究理事会;
关键词
Electroencephalography; Electromyography; Muscles; Correlation; Matrix decomposition; Covariance matrices; Underdetermined; joint canonical polyadic decomposition; artifact removal; auto-correlations; ELECTROENCEPHALOGRAM SIGNALS; IDENTIFICATION;
D O I
10.1109/TCSII.2019.2903648
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electroencephalography (EEG) recordings are often contaminated by artifacts from electromyogram (EMG). This artifact not only affects the visual analysis but also strongly impedes its various usages in biomedical research. With a sufficient number of EEG recordings, numerous blind source separation (BSS) methods can be applied to suppress or remove such EMG artifacts. However, in many practical applications (e.g., ambulatory health-care monitoring), the number of EEG sensors is often limited, while conventional BSS methods (e.g., independent component analysis) may fail to work in such cases. Considering the increasing need for acquiring EEG signals in ambulatory environments, we propose a novel underdetermined joint BSS method to remove EMG artifacts from EEG data with a limited number of EEG sensors. The performance of the proposed method is evaluated through numerical simulations in which EEG recordings are contaminated with muscle artifacts. The results demonstrate that the proposed method can effectively remove muscle artifacts while preserving EEG signals successfully.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [11] Comparison of Blind Source Separation Methods for Removal of Eye Blink Artifacts from EEG
    Soomro, Mumtaz Hussain
    Badruddin, Nasreen
    Yusoff, Mohd Zuki
    2014 5TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS 2014), 2014,
  • [12] Underdetermined Joint Blind Source Separation for Two Datasets Based on Tensor Decomposition
    Zou, Liang
    Chen, Xun
    Wang, Z. Jane
    IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (05) : 673 - 677
  • [13] Joint Nonnegative Matrix Factorization for Underdetermined Blind Source Separation in Nonlinear Mixtures
    Kopriva, Ivica
    LATENT VARIABLE ANALYSIS AND SIGNAL SEPARATION (LVA/ICA 2018), 2018, 10891 : 107 - 115
  • [14] UNDERDETERMINED SPARSE BLIND SOURCE SEPARATION OF NONNEGATIVE AND PARTIALLY OVERLAPPED DATA
    Sun, Yuanchang
    Xin, Jack
    SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2011, 33 (04): : 2063 - 2094
  • [15] A Novel Few-Channel Strategy for Removing Muscle Artifacts from Multichannel EEG Data
    Xu, Xueyuan
    Liu, Aiping
    Chen, Xun
    2017 IEEE GLOBAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (GLOBALSIP 2017), 2017, : 976 - 980
  • [16] Underdetermined Convolutive Blind Source Separation via Time-Frequency Masking
    Reju, Vaninirappuputhenpurayil Gopalan
    Koh, Soo Ngee
    Soon, Ing Yann
    IEEE TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2010, 18 (01): : 101 - 116
  • [17] ReMAE: User-Friendly Toolbox for Removing Muscle Artifacts From EEG
    Chen, Xun
    Liu, Qingze
    Tao, Wei
    Li, Luchang
    Lee, Soojin
    Liu, Aiping
    Chen, Qiang
    Cheng, Juan
    McKeown, Martin J.
    Wang, Z. Jane
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (05) : 2105 - 2119
  • [18] Artifacts-matched blind source separation and wavelet transform for multichannel EEG denoising
    Mowla, Md Rakibul
    Ng, Siew-Cheok
    Zilany, Muhammad S. A.
    Paramesran, Raveendran
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 22 : 111 - 118
  • [19] Blind source separation of EEG data using matched filters
    Köhler, BU
    Orglmeister, R
    Brehmeier-Flick, B
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2038 - 2041
  • [20] Removing muscle artifacts from EEG data of people with cognitive impairment using high order statistic methods
    Grigorios, Kalogiannis
    George, Chassapis
    Magda, Tsolaki
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2019, 22 : 165 - 173