Real Time Fault Detection in Photovoltaic Systems

被引:78
作者
Ali, Mohamed Hassan [1 ,3 ]
Rabhi, Abdelhamid [1 ]
El Hajjaji, Ahmed [1 ]
Tina, Giuseppe M. [2 ]
机构
[1] Univ Picardie Jules Verne, MIS Lab, 14 Quai Somme, F-80000 Amiens, France
[2] Univ Catania, DIEEI Dept, 2 Piazza Univ, I-95124 Catania, Italy
[3] Univ Djibouti, CRUD, Ave Djanaleh,Djibouti BP1904, Djibouti, Djibouti
来源
8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16 | 2017年 / 111卷
关键词
diagnosis; electrical signature; threshold of failure; model power; modeling; MODULE; MODEL;
D O I
10.1016/j.egypro.2017.03.254
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a method for real time monitoring and fault diagnosis in photovoltaic systems is proposed. This approach is based on a comparison between the performances of a faulty photovoltaic module, with its accurate model by quantifying the specific differential residue that will be associated with it. The electrical signature of each default will be fixed by considering the deformations induced on the I-V curves. Some faults, such as: interconnection resistance faults and different shading patterns are considered. The proposed technique can be generalized and extended to more types of faults. The fault diagnosis will be determined by fixing a normal and a fault threshold for each fault. These thresholds are calculated based on the Euclidean norm between ideal and normal measurement or between ideal and fault mode measurement. Each threshold is set in a range bounded by the minimum and maximum values of the differential residue obtained for the considered fault. The proposed approach provides identification of faults by calculating their specific threshold ranges. This method allows the instantaneous monitoring of the electrical power delivered by the photovoltaic system. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:924 / 933
页数:10
相关论文
共 17 条
  • [1] Alers G. B., 2011, SOLAR PHOTOVOLTAIC M
  • [2] Modeling and Simulation of Photovoltaic Module and Array based on One and Two Diode Model Using Matlab/Simulink
    Bouraiou, Ahmed
    Hamouda, Messaoud
    Chaker, Abdelkader
    Sadok, Mohammed
    Mostefaoui, Mohammed
    Lachtar, Salah
    [J]. INTERNATIONAL CONFERENCE ON TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY -TMREES15, 2015, 74 : 864 - 877
  • [3] Automatic supervision and fault detection of PV systems based on power losses analysis
    Chouder, A.
    Silvestre, S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (10) : 1929 - 1937
  • [4] Introducing the fractional-order Darwinian PSO
    Couceiro, Micael S.
    Rocha, Rui P.
    Fonseca Ferreira, N. M.
    Tenreiro Machado, J. A.
    [J]. SIGNAL IMAGE AND VIDEO PROCESSING, 2012, 6 (03) : 343 - 350
  • [5] Davarifar M., 2013, 2013 3rd International Conference on Systems and Control (ICSC), P727, DOI 10.1109/ICoSC.2013.6750940
  • [6] Davarifar M, 2012, INT C REN EN GEN APP, V12
  • [7] Ducange P., 2011, Proceedings of the 2011 11th International Conference on Intelligent Systems Design and Applications (ISDA), P1341, DOI 10.1109/ISDA.2011.6121846
  • [8] SIMPLIFIED METHOD FOR PREDICTING PHOTO-VOLTAIC ARRAY OUTPUT
    EVANS, DL
    [J]. SOLAR ENERGY, 1981, 27 (06) : 555 - 560
  • [9] A simple model of PV system performance and its use in fault detection
    Firth, S. K.
    Lomas, K. J.
    Rees, S. J.
    [J]. SOLAR ENERGY, 2010, 84 (04) : 624 - 635
  • [10] Simple, fast and accurate two-diode model for photovoltaic modules
    Ishaque, Kashif
    Salam, Zainal
    Taheri, Hamed
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2011, 95 (02) : 586 - 594