Detection of hypoventilation during deep sedation in patients undergoing ambulatory gynaecological hysteroscopy: a comparison between transcutaneous and nasal end-tidal carbon dioxide measurements

被引:29
作者
De Oliveira, G. S., Jr. [1 ]
Ahmad, S. [1 ]
Fitzgerald, P. C. [1 ]
McCarthy, R. J. [1 ]
机构
[1] Northwestern Univ, Dept Anesthesiol, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
capnography; complications; hypoventilation; deep sedation; intraoperative care; monitoring; transcutaneous blood gas; GENERAL-ANESTHESIA; CAPNOGRAPHY; OXIMETRY; SENSOR;
D O I
10.1093/bja/aeq092
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Transcutaneous measurement of carbon dioxide (Tc(CO2)) provides a non-invasive estimation of arterial carbon dioxide (Pa(CO2)). Nasal capnography (PE'(CO2)) is used to assess ventilation during monitored anaesthesia care (MAC) with sedation since it can readily detect apnoea. We compared the agreement between Tc(CO2) and PE'(CO2) with Pa(CO2) and the ability to detect hypercarbia in patients under deep sedation. Methods. Forty healthy female subjects receiving deep sedation for hysteroscopy were studied. A Tc(CO2) (TOSCA 500, Radiometer, Inc., Westlake, OH, USA) electrode was applied to the earlobe and PE'(CO2) capnography was monitored using nasal side-stream sampling. All subjects received oxygen (3 litre min 21). Subjects were evaluated at intervals using a modified Ramsay sedation score until they reached a score >= 5. Arterial blood gas values were compared with Tc(CO2) and PE'(CO2) values. Bland-Altman, linear regression, and receiver operator characteristics analysis were performed. Results. The mean (SD) absolute difference between the Tc(CO2), PE'(CO2), and the Pa(CO2) were 0.43 (0.35) and 1.06 (0.8) kPa, respectively (P=0.002). TcCO2 demonstrated a mean bias (2 SD) of 0.23 (0.07-0.4) kPa with Pa(CO2) compared with 20.93 (21.24 to 20.63) kPa for PE'(CO2). One minute before blood sampling, the sensitivity of the Tc(CO2) monitor for detecting Pa(CO2) >6.65 kPa was greater than for PE'(CO2) (66.7% vs 33.3%, P<0.01). Conclusions. Tc(CO2) demonstrated better agreement with Pa(CO2) than PE'(CO2) for patients under MAC with deep sedation. Tc(CO2) monitoring was more sensitive for detection of Pa(CO2) >6.65 kPa than PE'(CO2). Br J Anaesth 2010; 104: 774-8
引用
收藏
页码:774 / 778
页数:5
相关论文
共 12 条
[1]   Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients [J].
Bernet-Buettiker, V ;
Ugarte, MJ ;
Frey, B ;
Hug, MI ;
Baenziger, O ;
Weiss, M .
PEDIATRICS, 2005, 115 (01) :E64-E68
[2]   Evaluation of a new combined SpO2/PtcCO2 sensor in anaesthetized paediatric patients [J].
Dullenkopf, A ;
Bernardo, SD ;
Berger, F ;
Fasnacht, M ;
Gerber, AC ;
Weiss, M .
PAEDIATRIC ANAESTHESIA, 2003, 13 (09) :777-784
[3]  
Eberhard P, 2002, ANESTH ANALG, V94, pS76
[4]   Comparison of end-tidal and transcutaneous measures of carbon dioxide during general anaesthesia in severely obese adults [J].
Griffin, J ;
Terry, BE ;
Burton, RK ;
Ray, TL ;
Keller, BP ;
Landrum, AL ;
Johnson, JO ;
Tobias, JD .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (04) :498-501
[5]   ACCURACY OF CAPNOGRAPHY IN NONINTUBATED SURGICAL PATIENTS [J].
LIU, SY ;
LEE, TS ;
BONGARD, F .
CHEST, 1992, 102 (05) :1512-1515
[6]   A randomized, controlled trial of transcutaneous carbon dioxide monitoring during ERCP [J].
Nelson, DB ;
Freeman, ML ;
Silvis, SE ;
Cass, OW ;
Yakshe, PN ;
Vennes, J ;
Stahnke, LL ;
Herman, M ;
Hodges, J .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (03) :288-295
[7]   Noninvasive intraoperative monitoring of carbon dioxide in children: endtidal versus transcutaneous techniques [J].
Nosovitch, MA ;
Johnson, JO ;
Tobias, JD .
PAEDIATRIC ANAESTHESIA, 2002, 12 (01) :48-52
[8]   NONINVASIVE MONITORING OF CARBON-DIOXIDE - A COMPARISON OF THE PARTIAL-PRESSURE OF TRANS-CUTANEOUS AND END-TIDAL CARBON-DIOXIDE WITH THE PARTIAL-PRESSURE OF ARTERIAL CARBON-DIOXIDE [J].
PHAN, CQ ;
TREMPER, KK ;
LEE, SE ;
BARKER, SJ .
JOURNAL OF CLINICAL MONITORING, 1987, 3 (03) :149-154
[9]   A COMPARISON OF TRANSCUTANEOUS, END-TIDAL AND ARTERIAL MEASUREMENTS OF CARBON-DIOXIDE DURING GENERAL-ANESTHESIA [J].
REID, CW ;
MARTINEAU, RJ ;
MILLER, DR ;
HULL, KA ;
BAINES, J ;
SULLIVAN, PJ .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (01) :31-36
[10]  
Soto RG, 2004, ANESTH ANALG, V99, P379