Image quality of the proton imaging from computer-simulated data

被引:0
作者
Zhang Conghua [1 ]
Hou Qing [1 ]
Gou Chengjun [1 ]
Wu Zhangwen [1 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, Minist Educ, Chengdu 610064, Peoples R China
关键词
Monte Carlo method; Proton imaging; Image quality; Simulation image; TOMOGRAPHY; ION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, the proton image quality of three designed phantoms is studied by the Monte Carlo simulation tool FLUKA, and is compared with that of the photon, and electron imaging. The passages of parallel beams were simulated by the phantoms for protons, electrons and X-rays, and the fluence and energy spectra of exiting particles are recorded. The proton energy loss imaging has a high quality under low transmission proton fluence, and its quality is superior to that of electron and photon fluence. The results demonstrate that proton energy loss imaging is especially suitable for the samples of hundreds of nano-thicknesses.
引用
收藏
页码:20 / 23
页数:4
相关论文
共 12 条
  • [1] Advanced analytical techniques: platform for nano materials science
    Adams, F
    Van Vaeck, L
    Barrett, R
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) : 13 - 26
  • [2] DENSITY AND COMPOSITION ANALYSIS USING FOCUSED MEV ION MICROBEAM TECHNIQUES
    ANTOLAK, AJ
    BENCH, GS
    PONTAU, AE
    MORSE, DH
    HEIKKINEN, DW
    WEIRUP, DL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) : 568 - 574
  • [3] RADIOGRAPHY WITH PROTONS
    COOKSON, JA
    [J]. NATURWISSENSCHAFTEN, 1974, 61 (05) : 184 - 191
  • [4] Heavy ion and proton beams in high resolution imaging of a fungi spore specimen using STIM tomography
    Formenti, P
    Breese, MBH
    Connell, SH
    Doyle, BP
    Drummond, ML
    Machi, IZ
    Maclear, RD
    Schaaff, P
    Sellschop, JPF
    Bench, G
    SiderasHaddad, E
    Antolak, A
    Morse, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 130 (1-4) : 230 - 236
  • [5] FRANK W, 1997, NUCL INSTRUM METH B, V130, P1
  • [6] HANSON K M, 1981, Physics in Medicine and Biology, V26, P965, DOI 10.1088/0031-9155/26/6/001
  • [7] APPLICATION OF PROTONS TO COMPUTED TOMOGRAPHY
    HANSON, KM
    BRADBURY, JN
    CANNON, TM
    HUTSON, RL
    LAUBACHER, DB
    MACEK, R
    PACIOTTI, MA
    TAYLOR, CA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 657 - 660
  • [8] HARTMUT FW, 2004, IEEE T NUCL SCI, V51, P3
  • [9] PROTON IMAGING FOR MEDICAL APPLICATIONS
    KRAMER, SL
    MOFFETT, DR
    MARTIN, RL
    COLTON, EP
    STEWARD, VW
    [J]. RADIOLOGY, 1980, 135 (02) : 485 - 494
  • [10] ION MICROBEAM TOMOGRAPHY
    PONTAU, AE
    ANTOLAK, AJ
    MORSE, DH
    BERKMOES, AAV
    BRASE, JM
    HEIKKINEN, DW
    MARTZ, HE
    PROCTOR, ID
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 : 646 - 650