Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures A randomized controlled trial

被引:9
|
作者
Alzahem, Abdulrahman M. [1 ]
Aqil, Mansoor [2 ]
Alzahrani, Tariq A. [2 ]
Aljazaeri, Ayman H. [1 ]
机构
[1] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Pediat Surg, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Anesthesiol, Riyadh, Saudi Arabia
关键词
SUPRAGLOTTIC AIRWAY; ANESTHETIZED PATIENTS; INTRAOCULAR-PRESSURE; VENTILATED CHILDREN; PEDIATRIC-PATIENTS; COHORT EVALUATION; SCORING SYSTEM; INSERTION; LMA-CLASSIC(TM); PERFORMANCE;
D O I
10.15537/smj.2017.5.17960
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel group. Three groups underwent a subgroup analysis: <= 5 kg (group 1), 5.1-10.0 kg (group 2), and >10 kg (group 3). Results: The oropharyngeal leak pressure was significantly higher for the i-gel (25.4 +/- 4.1 cm H2O) than for the Ambu AO (22.5 +/- 3.9 cm H2O, p<0.001). The Ambu AO had a slightly higher ease of insertion compared to the i-gel (100% versus 94%, p=0.08) and required less manipulation (2% versus 11%, p=0.07). The Ambu AO and i-gel showed non-significant differences in performance between weight groups. There were statistically significant differences for higher leak pressure in group 2 (p=0.01) and group 3 (p=0.002) in favor of the i-gel, and for less manipulation in the Ambu AO in group 1 (p=0.04). Fiberoptic viewing was superior in group 2 for the i-gel (p=0.03) and in group 3 for the Ambu AO (p=0.02). Conclusion: Both devices demonstrated equally good performance with low morbidity. The Ambu AO had a statistical tendency towards easier insertion and less manipulation. Confirming this finding will require large scale trials.
引用
收藏
页码:482 / 490
页数:9
相关论文
共 50 条
  • [41] Comparison of oropharyngeal leak pressure of I-gel™ and Blockbuster™ laryngeal mask airway in anaesthetized pediatric patients
    Selvin, Caren Candace
    Singariya, Geeta
    Bihani, Pooja
    Kamal, Manoj
    Paliwal, Naveen
    Ujwal, Shobha
    ANESTHESIA AND PAIN MEDICINE, 2023, 18 (01): : 51 - 56
  • [42] Comparison between the Baska Mask® and I-Gel for Minor Surgical Procedures Under General Anaesthesia
    Sachidananda, Roopa
    Shaikh, Safiya, I
    Mitragotri, Milon Vasant
    Joshi, Vikas
    Ladhad, Dharmesh Arvind
    Mallappa, Marutheesh
    Bhat, Vikram Kemmannu
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2019, 47 (01) : 24 - 30
  • [43] A RANDOMISED CONTROLLED STUDY OF COMPARISON OF INTRAOCULAR PRESSURE AND HAEMODYNAMIC RESPONSES TO INSERTION OF THE I-GEL, CLASSICAL LARYNGEAL MASK AIRWAY AND ENDOTRACHEAL TUBE
    Khot, Aditya
    Jamale, P. B.
    Dhulkhed, V. K.
    Naik, Shraddha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (41): : 2614 - 2619
  • [44] Comparing leak pressure of LMA® ProSeal™ versus i-gel® at head rotation: a randomized controlled trial
    Chaki, Tomohiro
    Koizumi, Masatsugu
    Tachibana, Shunsuke
    Matsumoto, Tomomi
    Kumagai, Tomoe
    Hashimoto, Yuki
    Yamakage, Michiaki
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2024, 71 (01): : 66 - 76
  • [45] A randomized comparison of the laryngeal mask airway supreme and laryngeal mask airway unique in infants and children: does cuff pressure influence leak pressure?
    Jagannathan, Narasimhan
    Sohn, Lisa
    Sommers, Katherine
    Belvis, Dawn
    Shah, Ravi D.
    Sawardekar, Amod
    Eidem, Jami
    DaGraca, Justin
    Mukherji, Isabella
    PEDIATRIC ANESTHESIA, 2013, 23 (10) : 927 - 933
  • [46] Clinical Comparison of I-gel and Laryngeal Mask Airway-Supreme Airway Devices During General Anaesthesia in the Paediatric Population
    Aggarwal, Manish
    Yadav, Rahul
    Singh, Shalendra
    Bansal, Deepali
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (03) : 244 - 249
  • [47] The LMA-Supreme versus the I-gel in simulated difficult airway in children A randomised study
    Kus, Alparslan
    Gok, Cigdem N.
    Hosten, Tulay
    Gurkan, Yavuz
    Solak, Mine
    Toker, Kamil
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 (05) : 280 - 284
  • [48] Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia
    Choi, Jong Bum
    Kwak, Hyun Jeong
    Lee, Kyung Cheon
    Lee, Se Ryeon
    Lee, Sook Young
    Kim, Jong Yeop
    JOURNAL OF ANESTHESIA, 2016, 30 (03) : 377 - 383
  • [49] A randomized trial comparing the Ambu® Aura-i™ with the air-Q™ intubating laryngeal airway as conduits for tracheal intubation in children
    Jagannathan, Narasimhan
    Sohn, Lisa E.
    Sawardekar, Amod
    Gordon, Jason
    Shah, Ravi D.
    Mukherji, Isabella I.
    Roth, Andrew G.
    Suresh, Santhanam
    PEDIATRIC ANESTHESIA, 2012, 22 (12) : 1197 - 1204
  • [50] Efficiency of laryngeal mask airway Protector™ and i-gel® as a conduit in Aintree catheter-guided fibreoptic tracheal intubation: a randomised clinical trial
    Saracoglu, Kemal T.
    Turan, Ayse Z.
    Aydas, Asli D.
    Yilmaz, Mehmet
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2022, 54 (02) : 120 - 126